Crestron WD CRESNET TO MINI CAT5 User Manual

CRESNET MINI NETWORK CAT 5 INTERCONNECT DRAWING DATA SHEET
TWISTED
TWISTED
PAIR A
BLUE
PAIR C
TO
CONTROL SYSTEM
G Z Y
24
FRONT VIEW
TWISTED
PAIR B
TWISTED
PAIR C
TWISTED PAIR D
UNUSED (NOT SHOWN)
RECOMMENDED CATEGORY 5 CABLE COLOR CODE
WHITE
w/BLUE STRIPE
1 TO 1 PINOUT REFERENCE
24
Y Z G
24
Y Z G
TO
24
Y Z G
FRONT VIEW
TWISTED
PAIR A
TWISTED
PAIR B
TWISTED
PAIR C
TO
NETWORK DEVICE
24
Y Z G
GND
24
=
GREEN AND WHITE w/GREEN STRIPE
Z
=
WHITE w/BLUE STRIPE
Y
=
BLUE
=
ORANGE AND WHITE w/ORANGE STRIPE
PAIR A
PAIR B
PAIR C
FRONT VIEW
TWISTED
PAIR A
BROWN AND WHITE w/BROWN STRIPE=SPARES PAIR D (NOT SHOWN)
CAUTION: POSSIBLE EQUIPMENT DAMAGE IF MISWIRED.
DO NOT POWER UP SYSTEM UNTIL ALL WIRING IS VERIFIED.
CARE SHOULD BE TAKEN TO ENSURE DATA (Y,Z) AND POWER (24,G) CONNECTIONS ARE NOT CROSSED.
TO CALCULATE MAX. CAT 5 CABLE LENGTH L = MAXIUM CABLE LENGTH (FEET) PF = TOTAL POWER FACTOR FOR EQUIPMENT
L =
3000
PF
ON RUN (WATTS)
MODEL CNHBLOCK: NETWORK DISTRIBUTION BLOCK IS RECOMMENDED FOR TESTING PURPOSES AND CONVENIENCE IN WIRING.
CRESTRON ELECTRONICS, INC. ROCKLEIGH, N.J. 1-888-CRESTRON
Specifications subject to change without notice 04.02 Doc. 5819B