Crestron TST-600-IMCW Installation Manual

Page 1
Crestron TST-600-IMCW Interface Module for TST-600-DS Installation Guide
Page 2
This document was prepared and written by the Technical Documentation department at:
Regulatory Compliance
As of the date of manufacture, the TST-600-IMCW has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
Federal Communications Commission (FCC) Compliance Statement
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
The specific patents that cover Crestron products are listed at patents.crestron.com.
Crestron, the Crestron logo and Cresnet are either trademarks or registered trademarks of Crestron Electronics, Inc. in the
United States and/or other countries. Other trademarks, registered trademarks and trade names may be used in this
document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary
interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.
©2013 Crestron Electronics, Inc.
Page 3
Crestron TST-600-IMCW Interface Module for TST-600-DS
Contents
Interface Module for TST-600-DS: TST-600-IMCW 1
Introduction ............................................................................................................................... 1
Features and Functions ................................................................................................ 1
Specifications .............................................................................................................. 2
Physical Description .................................................................................................... 4
Setup .......................................................................................................................................... 7
Network Wiring ........................................................................................................... 7
Supplied Hardware ...................................................................................................... 7
Installation ................................................................................................................... 8
Hardware Hookup ..................................................................................................... 10
Problem Solving ...................................................................................................................... 12
Troubleshooting ......................................................................................................... 12
Reference Documents ................................................................................................ 13
Further Inquiries ........................................................................................................ 13
Future Updates .......................................................................................................... 13
Return and Warranty Policies .................................................................................................. 14
Merchandise Returns / Repair Service ...................................................................... 14
Crestron Limited Warranty ........................................................................................ 14
Installation Guide – DOC. 7385A Contents i
Page 4
Page 5
Crestron TST-600-IMCW Interface Module for TST-600-DS
Single wire connection for the TST-600-DS
Interface Module for TST-600-DS: TST-600-IMCW

Introduction

The TST-600-IMCW is the interface module that is included as standard with the Crestron TST-600 Wireless Touch Screen). It is also available separately to provide an additional plug-in connection point. The docking station connects to the interface module via a 10-pin RJ-50 jack.
The TST-600-IMCW interface module provides power to the touch screen via the docking station. Power is supplied to the interface module via the included power pack. As an alternative to using the power pack, the interface module may be connected to a Cresnet panel connector.*
®
TST-600-DS TableTop Docking Station (and
®
network via the rear

Features and Functions

Mounts in a single-gang electrical box
Surface mount and rack rail installation options included
Includes inserts to match black or white faceplates
Wired Ethernet control system connections
Versatile powering options
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 1
* Does not support Cresnet data communication, only power.
Page 6
Interface Module for TST-600-DS Crestron TST-600-IMCW
SPECIFICATION
DETAILS
(power pack included)
Environmental
Temperature
32º to 112º F (0º to 45º C)
Enclosure
panel
Flush Wall Mount
1-gang mountable in a standard
In addition to power, the interface module includes a LAN port which may be connected to an Ethernet network to enable wired communication with the touch screen when it is on the docking station.
Using the hardware provided, the TST-600-IMCW can be mounted in a standard 1-gang electrical box or attached to a 19-inch rack rail or any suitable flat surface. A set of front panel inserts is included to match either white or black decorator style wall plates (wall plates not included).

Specifications

Specifications for the TST-600-IMCW are listed in the following table.
TST-600-IMCW Specifications
Power Requirements1 Power Pack 0.75 amps @ 24 Vdc
Cresnet Power Usage 0.5 watts (0.02 amps @ 24 Vdc),
interface module only; 18 watts (0.75 amps @ 24 Vdc),
2
with TPS-600-DS connected
Humidity 10% to 90% RH (non-condensing) Heat Dissipation 7 Btu/h
Construction Metal, black finish, includes (2)
metal decorator style inserts to allow choice of black or white front
Surface Mount Surface mount bracket included
(Continued on following page)
2 Interface Module for TST-600-DS: TST-600-IMCW Installation Guide – DOC. 7385A
electrical box, 2.5 inch (64 mm) deep minimum; requires decorator style faceplate (not included)
Page 7
Crestron TST-600-IMCW Interface Module for TST-600-DS
Dimensions
Height
4.12 in (105 mm)
Depth
1.67 in (43 mm)
Weight
6 oz (149 g) Included Accessory
24 Volt Power Pack, Universal
CBL-CAT5E
Ethernet LAN Cable
TST-600-IMCW Specifications (Continued)
SPECIFICATION DETAILS
Enclosure (Continued) Rack Mount Mountable to a single 19-inch EIA
rack rail
Width 1.72 in (44 mm)
1.93 in (49 mm) with surface mount bracket
8 oz (219 g) with bracket
Available Accessory
1. May be powered by power pack or Cresnet network power, not both.
2. When ordering a TST-600 Wireless Touch Screen, (1) TST-600-DS TableTop
Docking Station and (1) TST-600-IMCW Interface Module are included. When ordering a TST-600-DS, (1) TST-600-IMCW is included. When ordering a TST-600-IMCW, no TST-600 or TST-600-DS is included.
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 3
Page 8
Interface Module for TST-600-DS Crestron TST-600-IMCW
1
2
3
1.67 in
(43 mm)
4.12 in
(105 mm)
5
4
1.72 in
(44 mm)
5.00 in
(127 mm)
6

Physical Description

This section provides information on the connections, controls and indicators available on the TST-600-IMCW.
TST-600-IMCW Overall Dimensions (Front, Rear and Side Views)
4 Interface Module for TST-600-DS: TST-600-IMCW Installation Guide – DOC. 7385A
Page 9
Crestron TST-600-IMCW Interface Module for TST-600-DS
TYPE
PIN
COLOR
SIGNALS
10-Position
1
Gray
Ground
2
Orange/
White
Ethernet TX+
3
Orange
Ethernet TX-
4
Green/
White
Ethernet RX+
5
Blue
N/C
6
Blue/
White
N/C 7 Green
Ethernet RX-
8
Brown/
White
N/C
9
Brown
N/C
10
Gray/ White
Power 24V
2
PWR LED
(1) Green LED, indicates dc power
Connectors, Controls & Indicators
# CONNECTORS1,
CONTROLS &
INDICATORS
1 TO PANEL
DESCRIPTION
(1) 10-wire RJ-50 female; Connection for TST-600-DS TableTop Docking Station
RJ-50
2
3 PWR
24VDC .75A
(Continued on following page)
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 5
supplied from power pack or Cresnet network3
(1) 2.1 x 5.5 mm dc power connector; 24 Vdc power input; Power pack included
Page 10
Interface Module for TST-600-DS Crestron TST-600-IMCW
TYPE
PIN
SIGNALS
8-Position
1
TD+
2
TD-
3
RD+
4
N/C
5
N/C
6
RD-
7
N/C
8
N/C
24 Vdc power input
6
GROUND4
(1) Flying lead, grounding wire
Connectors, Controls, & Indicators (Continued)
# CONNECTORS1,
CONTROLS &
INDICATORS
4 LAN
5 24 G
DESCRIPTION
(1) 8-wire RJ-45; 10BASE-T/100BASE-TX Ethernet port
RJ-45
(1) 2-pin 3.5 mm detachable terminal block;
1. An interface connector for the 24 G port is provided with the unit.
2. When ordering a TST-600 Wireless Touch Screen, (1) TST-600-DS TableTop
Docking Station and (1) TST-600-IMCW Interface Module are included. When ordering a TST-600-DS, (1) TST-600-IMCW is included. When ordering a TST-600-IMCW, no TST-600 or TST-600-DS is included.
3. Does not support Cresnet data communication, only power.
4. A grounding lead is provided for connection to earth ground (building steel). This
ground connection is recommended to provide a common ground reference for signals provided to the TST-600-IMCW and to reduce the incidence of possible damage to the unit from static discharge.
6 Interface Module for TST-600-DS: TST-600-IMCW Installation Guide – DOC. 7385A
Page 11
Crestron TST-600-IMCW Interface Module for TST-600-DS
Assy, Insert, Black
4509271
1
Assy, Insert, White
4509273
1
Metal, Bracket, 16 GA CRS
2016054
1
Screw, #06-32 x 1”, Flat, Slot
2013235
2
Screw, #06-32 x 3/16”, Pan, Phil
2007203
2

Setup

Network Wiring

When wiring the Ethernet network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
Unlike other Crestron network devices, the TST-600-IMCW does not use Cresnet for communications between the device and the control system. The TST-600-IMCW requires the use of a high-speed Ethernet connection for control system communications.
For general information on connecting Ethernet devices in a Crestron system, refer to the latest version of the Crestron e-Control Guide (Doc. 6052), which is available from the Crestron Web site (
www.crestron.com/manuals).
Reference

Supplied Hardware

The hardware supplied with the TST-600-IMCW is listed in the following table.
Supplied Hardware for the TST-600-IMCW
DESCRIPTION PART
NUMBER
Conn, Plug, 2-pin, SKT, Single Row 2003574 1
QTY
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 7
Page 12
Interface Module for TST-600-DS Crestron TST-600-IMCW
1-Gang Box
mounted into the electrical box as shown in the following illustration.
1-Gang Electrical Box (Not Included)
TST-600-IMCW
S
cre
ws (2) #06-32 x 1”
(2013235)
Wall Plate with Hardware (Not Included)
Assy, Insert, Black (4509271) or Assy, Insert, White (4509273)
Moun
ti
ng
Surface

Installation

The TST-600-IMCW can be installed in either a 1-gang box, rack mounted or mounted to any flat surface using the provided surface mount bracket.
Installing in
To install the TST-600-IMCW in a 1-gang box, ensure the unit is
TST-600-IMCW 1-Gang Box (Exploded View)
8 Interface Module for TST-600-DS: TST-600-IMCW Installation Guide – DOC. 7385A
Page 13
Crestron TST-600-IMCW Interface Module for TST-600-DS
shown in the following illustration.
Rack Mount Screws (Not Included)
Rack Rail
Assy, Insert, Black (4509271) or Assy, Insert, White (4509273
TST-600-IMCW
Rack Mounting
The TST-600-IMCW can be mounted in a rack with other equipment using the four mounting holes on the corners of the interface module, as
TST-600-IMCW Rack Mount (Exploded View)
WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, observe the following guidelines:
When mounting this unit in a partially filled rack, load the rack
from the bottom to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the
stabilizers before mounting or servicing the unit in the rack.
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 9
Page 14
Interface Module for TST-600-DS Crestron TST-600-IMCW
Surface
following illustration.
Assy, Insert, Black (4509271) or Assy, Insert, White (4509273)
TST-600-IMCW
Screws (2) #06-32 x 3/16” (2007203)
Mounting Bracket (2016054)
Installing on a Level
To prepare the TST-600-IMCW to be mounted onto a level surface, ensure the unit is attached to the surface mount bracket, as shown in the
TST-600-IMCW Bracket Mount (Exploded View)
10 Interface Module for TST-600-DS: TST-600-IMCW Installation Guide – DOC. 7385A

Hardware Hookup

Make the necessary connections as called out in the illustration on the following page. Refer to “Network Wiring” on page 7. Apply power after all connections have been made.
When making connections to the TST-600-IMCW, use Crestron power supplies for Crestron equipment.
Page 15
Crestron TST-600-IMCW Interface Module for TST-600-DS
T
O
P
ANEL:
Connect to
TST-600-DS
Docking Station via
10-Pin RJ-50 Cable
(Provided with
Docking Station)
PWR*:
From DC
Power Pack
LAN:
10BASE-
T /
100BASE-TX
Ethernet to LAN
24 G:
24 VDC
Power Input
Hardware Connections for the TST-600-IMCW (Front)
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 11
* A ferrule dust cap is provided to cover the dc power jack when not in use.
Hardware Connections for the TST-600-IMCW (Rear)
NOTE: Ensure the unit is properly grounded by connecting the chassis ground wire to an earth ground (building steel).
Page 16
Interface Module for TST-600-DS Crestron TST-600-IMCW
connections.
system.
connections.
Loss of
Improper
Check that all ground

Problem Solving

Troubleshooting

The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative.
TST-600-IMCW Troubleshooting
TROUBLE POSSIBLE
CAUSE(S)
Device does not function.
PWR LED does not illuminate.
Use the Crestron
Device is not receiving sufficient power.
Use the Crestron
Device is not receiving sufficient power.
CORRECTIVE
ACTION
Use a Crestron approved power source and verify
Power Calculator to help calculate how much power is needed for the
Use a Crestron approved power source and verify
Power Calculator to help calculate how much power is needed for the system.
12 Interface Module for TST-600-DS: TST-600-IMCW Installation Guide – DOC. 7385A
functionality due to electrostatic discharge.
grounding.
connections have been made properly.
Page 17
Crestron TST-600-IMCW Interface Module for TST-600-DS
Crestron e-Control Reference Guide

Reference Documents

The latest version of all documents mentioned within the guide can be obtained from the Crestron Web site (
List of Related Reference Documents
www.crestron.com/manuals).
DOCUMENT TITLE

Further Inquiries

To locate specific information or resolve questions after reviewing this guide, contact Crestron's True Blue Support at 1-888-CRESTRON [1-888-273-7876] or refer to the listing of Crestron worldwide offices on the Crestron Web site ( particular geographic region.
www.crestron.com/offices) for assistance within a
To post a question about Crestron products, log onto the Online Help section of the Crestron Web site ( First-time users must establish a user account to fully benefit from all available features.
www.crestron.com/onlinehelp).

Future Updates

As Crestron improves functions, adds new features and extends the capabilities of the TST-600-IMCW, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
Check the Crestron Web site periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column.
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 13
Page 18
Interface Module for TST-600-DS Crestron TST-600-IMCW

Return and Warranty Policies

Merchandise Returns / Repair Service

1. No merchandise may be returned for credit, exchange or service without prior authorization from
Crestron. To obtain warranty service for Crestron products, contact an authorized Crestron dealer. Only authorized Crestron dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address.
2. Products may be returned for credit, exchange or service with a Crestron Return Merchandise
Authorization (RMA) number. Authorized returns must be shipped freight prepaid to Crestron, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. Crestron reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by Crestron,
shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.

Crestron Limited Warranty

Crestron Electronics, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from Crestron, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touch screen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any.
Crestron shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall Crestron be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. Crestron is not liable for any claim made by a third party or made by the purchaser for a third party.
Crestron shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, Crestron makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
14 Interface Module for TST-600-DS: TST-600-IMCW Installation Guide – DOC. 7385A
Page 19
Crestron TST-600-IMCW Interface Module for TST-600-DS
This page is intentionally left blank.
Installation Guide – DOC. 7385A Interface Module for TST-600-DS: TST-600-IMCW 15
Page 20
Crestron Electronics, Inc. Installation Guide – DOC. 7385A
15 Volvo Drive Rockleigh, NJ 07647 (2034465) Tel: 888.CRESTRON 01.13 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
Loading...