Crestron FT-600 Operations & Installation Manual

Page 1
Crestron FT-600 FlipTop™ Basic Operations & Installation Guide
Page 2
Regulatory Compliance
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
As of the date of manufacture, the FT-600 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
The specific patents that cover Crestron products are listed at patents.crestron.com.
errors in typography or photography.
This document was written by the Technical Publications department at Crestron. ©2013 Crestron Electronics, Inc.
Page 3
Crestron FT-600 FlipTop Basic
Contents
FlipTop Basic: FT-600 1
Introduction ............................................................................................................................... 1
Features and Functions ................................................................................................ 1
Specifications .............................................................................................................. 3
Physical Description .................................................................................................... 4
Setup .......................................................................................................................................... 8
Supplied Hardware ...................................................................................................... 8
Installation ................................................................................................................... 8
Resources ................................................................................................................................. 12
Further Inquiries ........................................................................................................ 12
Future Updates .......................................................................................................... 12
Return and Warranty Policies .................................................................................................. 13
Merchandise Returns / Repair Service ...................................................................... 13
Crestron Limited Warranty ........................................................................................ 13
Operations & Installation Guide – DOC. 7596A Contents i
Page 4
Page 5
Crestron FT-600 FlipTop Basic
Flush mount tabletop connectivity in a stylish FlipTop design
FlipTop Basic: FT-600

Introduction

The FT-600 FlipTop™ Basic by Crestron® provides a highly configurable connectivity solution in a stylish, flush mount tabletop design. Flipping open the “FlipTop” lid accesses its connection compartment where interface cables and connectors are kept at the ready for plugging in laptop computers, mobile devices, AV source, and other equipment. A FlipTop is an ideal complement to a DigitalMedia™ transmitter or any other AV interface device, providing easy access to necessary connections while keeping the more intimidating and mundane technology hidden away beneath the tabletop.

Features and Functions

An ideal complement to Crestron DigitalMedia
Configurable connection compartment allows versatile combinations of
FlipTop Design
Handsomely finished in a choice of black anodized or brushed aluminum, Crestron FlipTops lend a contemporary metallic accent to conference tables and podiums. The FT-600 installs cleanly in virtually any flat, horizontal surface up to 1 3/4” (44 mm) thick. Beveled edges provide for a nearly flush appearance.
The FlipTop lid flips open with just the tip of a finger to access the connection compartment. Once connections are made, the lid can be closed. A generous, tapered notch at the front of the lid opening allows interface cables to remain connected even when the lid is closed.
pull-out cables, cable retractors, connector plates, and AC power outlets
Tapered cable notch allows lid to be closed with cables plugged in
Universal cutout size fits all new and future FlipTops
Black anodized or brushed aluminum finish
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 1
Page 6
FlipTop Basic Crestron FT-600
Connection Compartment
The FT-600 is highly configurable to provide a well organized connectivity solution tailored to each unique application. It provides options for both pullout and panel­mounted connectors, with or without AC power outlets. It comes standard with two cable pass-through plates and four blank plates, all of which can be swapped out for a choice of cable retractors, connector plates, and AC power outlet modules.
Cable Pass-Through Plates – Each cable pass-through plate provides four
grommeted holes to accommodate Crestron Certified Interface Cables* and other AV, data, and communication cables. The user end of each cable stows neatly within the connection compartment ready for use while excess cable simply drops out of sight below the cable pass-through plate. The grommets provide a smooth, slippery surface for easy pullout of each cable. Blank caps are also provided to cover any unused holes. The cable pass-through plates are positioned at the left and right sides of the connection compartment. The FT-600 supports one or two cable pass-through plates. Two are included.
Cable Retractors – For an even more refined cable management solution,
the FT-600 accommodates up to six Crestron CBLR Cable Retractors*. Crestron cable retractors feature a patent pending, lever actuated retraction mechanism that ensures smooth operation while eliminating hanging cable loops beneath the table. Up to three cable retractors can be installed in place of each cable pass-through plate, allowing for a total of six cable retractors.
Connector Plates – If panel mounted connectors are preferred, the FT-600
can accommodate up to four FTA-CP Connector Plates*. Connector plates are offered with a variety of common AV and data connector types. Custom connector plates may also be fabricated by the installer using the blank plates provided. All four connector plates are positioned at the center of the connection compartment.
AC Power Outlet Modules – To provide power for laptops and other
portable devices, the FT-600 can be equipped with up to four AC power outlets. A single FTA-PWR-102 Dual AC Power Outlet Module* can be installed in place of the center two connector plates or two FTA-PWR-102s can be installed in place of all four connector plates.
* Item(s) sold separately.
2 FlipTop Basic: FT-600 Operations & Installation Guide – DOC. 7596A
Page 7
Crestron FT-600 FlipTop Basic

Specifications

Specifications for the FT-600 are listed in the following table.
FT-600 Specifications
SPECIFICATION DETAILS
Power Requirements
Utility power 10 amps at 125 Vac 50/60 Hz per each installed
Dual AC Power Outlet Module (FTA-PWR-102, sold separately)
Environmental
Temperature 32º to 112º F (0º to 45º C)
Humidity 10% to 90% RH (non-condensing)
Enclosure
Chassis Metal, black
Cover Aluminum, black anodized or brushed aluminum
finish
Mounting Flush tabletop mount, 1 3/4 in (44 mm)
maximum surface thickness, 6 1/4” (159 mm) deep x 7 1/2 in (190 mm) wide cutout (template provided)
Dimensions
Height 7.06 in (180 mm)
10.80 in (275 mm) with lid open
Width 7.98 in (203 mm)
9.19 in (234 mm) with mounting brackets
Depth 6.77 in (172 mm)
7.88 in (200 mm) with lid open
Weight 5.6 lb (2.5 kg)
Available Models
FT-600-B FlipTop Basic, Black Anodized
FT-600-BALUM Flip Top Basic, Brushed Aluminum
Available Accessories
CBL Series Crestron Certified Interface Cables
CBLR Series Cable Retractors
CBLRA-BRKT-3-H Horizontal Mounting Option for CBLR
CBLRA-INSERT-2WIRE 2-Wire Insert for Cable Retractor Option
FTA-CP-DP-101 FlipTop Connector Plate, DisplayPort
FTA-CP-HD-101 FlipTop Connector Plate, HDMI
FTA-CP-RCA-103 FlipTop Connector Plate, RCA x 3
FTA-CP-RJ45-102 FlipTop 2 Connector Plate, RJ45 x 2
FTA-CP-USB-102 FlipTop Connector Plate, USB x 2
FTA-PWR-102 FlipTop Dual AC Power Outlet Module, NEMA 5
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 3
Page 8
FlipTop Basic Crestron FT-600
6.22 in
(158 mm)
7.98 in
(203 mm)
6.77 in
(172 mm)

Physical Description

This section provides information on the connections, controls, and indicators available on the FT-600.
FT-600 Overall Dimensions (Top View)
4 FlipTop Basic: FT-600 Operations & Installation Guide – DOC. 7596A
Page 9
Crestron FT-600 FlipTop Basic
7.28 in
(185 mm)
6.72 in
(171 mm)
FT-600 Overall Dimensions (Front View)
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 5
Page 10
FlipTop Basic Crestron FT-600
7.06 in
(180 mm)
6.94 in
(177 mm)
3.75 in
(95 mm)
5.12 in
(130 mm)
6.07 in
(155 mm)
7.88 in
(200 mm)
FT-600 Overall Dimensions (Side View)
6 FlipTop Basic: FT-600 Operations & Installation Guide – DOC. 7596A
Page 11
Crestron FT-600 FlipTop Basic
Ground
FT-600 (Oblique View)
FT-600 (Bottom View)
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 7
Page 12
FlipTop Basic Crestron FT-600

Setup

Supplied Hardware

The hardware supplied with the FT-600 is listed in the following table.
Supplied Hardware for the FT-600
DESCRIPTION PART NUMBER QUANTITY
Metal, Plate, Mounting 2036985 2
Screw, 10-32 x 2”, Steel, Socket HD, Zinc 2037109 4
Small Hole Plug 2036647 4
Large Hole Plug 2036649 4
Small Bushing, 5/16” ID, 0.5” OD 2009522 4
Large Bushing, 0.55” ID, 0.80” OD 2010496 4

Installation

NOTE: To prevent overheating, do not operate this product in an area that exceeds the environmental temperature range listed in the table of specifications. Consideration must be given if installed in a closed assembly, inside a closed desk or in a closed podium since the operating ambient temperature of these environments may be greater than the room ambient temperature. Contact with thermal insulating materials should be avoided on all sides of the unit.
Cable Management Plates
The FT-600 ships with two cable management plates pre-installed. These provide a pullout cable solution for the cables. Cables are looped through the cable management plates.
The included bushings must be installed before mounting the FT-600 in a surface. For a neat appearance, any unused openings can be filled using the included hole plugs. The only tool required is a Phillips screwdriver.
1. Remove the two cable management plates and retain the 06-32 x 1/4” screw
that holds each one in place.
2. Place the bushings on the cables (eight bushings supplied).
3. Thread the cables through the appropriate slots on each plate.
4. Snap the bushings into the plate slots.
5. Feed all excess cable through the opening.
6. Attach each plate by first sliding its dovetail into the slot toward the rear of
the inside of the FT-600, then dropping the front into place and securing it with the 06-32 x 1/4” screw from step 1. Refer to the following illustration.
8 FlipTop Basic: FT-600 Operations & Installation Guide – DOC. 7596A
Page 13
Crestron FT-600 FlipTop Basic
Cable Management Plates (2)
Bushing
06-32 x 1/4” Screws (2)
Mounting Plate Dovetail Inserts Here
Maximum
Radius
1/8 in
(4 mm)
6 1/4 in
(159 mm)
7 1/2 in
(190 mm)
Cable Management Plate Installation
Mounting in a Surface
The FT-600 is designed to mount in a horizontal surface, such as a desktop, lectern, or podium. The following diagram illustrates the required opening size to accommodate the FT-600. A cutout template (40143) is included.
Cutout Dimensions
NOTE: Before inserting the FT-600 in the mounting hole, ensure that all required cables have been installed.
Tools required:
Phillips screwdriver
#10 Allen wrench
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 9
Page 14
FlipTop Basic Crestron FT-600
Surface Cutout
Studs for Mounting Plate
Use the following procedure to mount the FT-600.
1. Position the FT-600 in the mounting hole.
Mounting Plate Stud Locations
2. Install the four #10-32 socket screws (2037109) in the metal mounting
plates (2036985) (two screws per plate). Refer to the following illustration.
10 FlipTop Basic: FT-600 Operations & Installation Guide – DOC. 7596A
Page 15
Crestron FT-600 FlipTop Basic
Screws (4) #10-32 x 2”, Steel, Socket HD
Mounting Plates (2)
Mounting Surface
Mounting Plate Installation
3. Slide the mounting plates over the studs on each side of the FT-600.
4. Turn the four #10-32 socket screws equally, until they contact the underside
of the mounting surface.
NOTE: Do not overtighten the #10 screws as this may damage the surface or the unit.
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 11
Page 16
FlipTop Basic Crestron FT-600

Resources

Further Inquiries

To locate specific information or resolve questions after reviewing this guide, contact Crestron's True Blue Support at 1-888-CRESTRON [1-888-273-7876] or, for assistance within a particular geographic region, refer to the listing of Crestron worldwide offices at
To post a question about Crestron products, log onto Crestron’s Online Help at
www.crestron.com/onlinehelp. First-time users must establish a user account to fully
benefit from all available features.

Future Updates

As Crestron improves functions, adds new features, and extends the capabilities of the FT-600, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
www.crestron.com/offices.
Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column.
12 FlipTop Basic: FT-600 Operations & Installation Guide – DOC. 7596A
Page 17
Crestron FT-600 FlipTop Basic

Return and Warranty Policies

Merchandise Returns / Repair Service
1. No merchandise may be returned for credit, exchange or service without prior authorization from
Crestron. To obtain warranty service for Crestron products, contact an authorized Crestron dealer. Only authorized Crestron dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address.
2. Products may be returned for credit, exchange or service with a Crestron Return Merchandise
Authorization (RMA) number. Authorized returns must be shipped freight prepaid to Crestron, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. Crestron reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by Crestron,
shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.
Crestron Limited Warranty
Crestron Electronics, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from Crestron, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touch screen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any.
Crestron shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall Crestron be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. Crestron is not liable for any claim made by a third party or made by the purchaser for a third party.
Crestron shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, Crestron makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 13
Page 18
FlipTop Basic Crestron FT-600
This page is intentionally left blank.
14 FlipTop Basic: FT-600 Operations & Installation Guide – DOC. 7596A
Page 19
Crestron FT-600 FlipTop Basic
This page is intentionally left blank.
Operations & Installation Guide – DOC. 7596A FlipTop Basic: FT-600 15
Page 20
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 7596A
15 Volvo Drive Rockleigh, NJ 07647 (2038123) Tel: 888.CRESTRON 10.13 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
Loading...