
FT2-1400-ELECSeries
FlipTop™FT2 SeriesCableManagement System,1400Size,Electrical
retractors,active connectorplates, andUSB rapidcharging
modules. Italsoenables backlightingof the symbol icons onall
retractors,connector plates,andUSBchargingmodules.
QuickandSimple TabletopInstallation
Thoughtful installationfeatures andaccessories savetimeand
effort.Mountingthe FlipTopisassimpleascuttingthe hole,
placingtheunit, andturningfourscrewstoengage the
swivelingdogsthatsecure the FlipTopinplace. Then installthe
dropin modulesandaddanyundertable accessories. To
complete the installation,the topcoverbezelsnaps intoplace
magnetically.
See also the FT2-1400-MECHseries FlipTopsystemsfora
lowercostalternative withreducedfeatures andoptions.
1,4
FT2-1400-ELEC-Bwithmodules (notincluded) installed
l
Dashboard-forwarddesignkeeps connections close tothe
surface
l
Backlitsymboliconsonspecificaccessories (soldseparately)
illuminateforclearidentification in a darkenedroom
l
Available in blackandalloymetalfinishes
l
One-touch lidretracts anddisappears atthetapof a button
l
Provides 18 moduleslotsarrangedin2 rows (9 modules per
1
row)
l
Adjustable plates accommodate a varietyof cables with
varyingconnectorshapes andsizes
l
Fitsa6-3/4in.(171mm)deepx10in. (254mm)rectangular
cutout(templateincluded)
l
Optionalaccessories include pass-throughcables, gravity
cable retractors,one-touchcable retractors, active
connectorplates, USB rapidchargers, flush-mountkeystone
connectorplates, internationalAC power outlets,anda
utilityshelf
3
TheCrestron® FT2-1400-ELECFlipTop™ cablemanagement
systeminstallsintoatableorotherhorizontalsurface to
provide modularconnectivity.The FT2-1400-ELECseries
feature a one-touchlidthatretractsfullyanddisappearswith
thetapofabutton.When the lid is retracted,18 moduleslots
arearrangedintworows of nine. The flexiblemodulardesign
mayalsobecustomizedwith anassortmentofCrestron
accessories.For more informationaboutthe accessories,
pleasevisitwww.crestron.com/Crestron-FlipTops. To configure
yourFlipTop,launch the FlipTopConfigurationTool.
All connectionsreside atthe topsurface,clearlyvisible and
readilyaccessible. A selectionofmodularcomponents enables
customconfigurationandquickinstallation. Backlitsymbolicons
clearlyidentifytheconnectiontype under anylighting
condition.1Precisionfitandfinishaffords functionalityanda
cleanappearance withmachinedmetalsurfacesfinishedin a
choiceofblackoralloy.
TheFT2-1400-ELECSeries features a builtinelectricalpower
bus,whichenables compatibilitywith one-touchcable
ModularDesign
TheFT2-1400-ELECdeliversacustomizable connectivity
solution witheasy-to-install accessories such as pulloutcables,
flushmountconnectors, andACpoweroutlets. The final
installation provides one smooth,contiguoussurface withno
visiblegapsor screws, andthemodules mayberearrangedat
anytime.
Modules andAccessories
NOTE: Allmodules andaccessories aresoldseparatelyand
arenotincludedintheFT2-1400-ELEC.
l Pass-ThroughCables andCable Pass -ThroughPlates: The
pass-through cablesandplates work together to offer a
simplecable managementsolution.Each pass-through
cable installsintheFlipTopassemblyusinga cablepassthroughplate module, which allowsthecable to be pulled
outsmoothlyfor use andthendroppedbackintothe
FlipTop.For details,refer to the FT2A-CBL-PTand
FT2A-PLT-PT-10 productpages.
l One-TouchCableRetractors:At the touchofa button,
cables retractgracefullyandthe cableloopis contained
beneath thetable. The retractor buttonincludesabacklit
symboliconthatindicatesthecable connectortype.Onetouch cableretractorsmaybe installedinthemiddleofa
rowbyaddinganmid-rowadapter bracket(sold
separately).
1,2
WhentheFT2-1400-ELECisconnected toa
Crestroncontrolsystemor DMPS, customprogramming
provides additional functionality, such as triggering
retractionbased on occupancyor scheduling.For details,
refer to the FT2A-CBLR-1Tproductpage.
l GravityCable Retractors:Gravitycable retractors employa
precisiongravity-assistedtrackandpulleymechanism
housedwithinanarrow, verticalenclosurethatextends
beneath theFlipTopchassis. Theymaybe installedinthe
middle of arowbyaddinganmid-rowadapter bracket(sold
separately).
1,2
For details,refer totheFT2A-CBLR-GR
productpage.

FT2-1400-ELECSeries
FlipTop™FT2 SeriesCableManagement System,1400Size,Electrical
l ConnectorPlates:Connectorplate modulesprovide a
selectionofpanel mountedconnectors,whichallowthe
connectionofdevicesusingseparate,detachedinterface
cables (not included).Eachconnector platemoduleincludes
abacklitsymboliconthatindicatestheconnectortype. For
details, refertothe FT2A-CP productpages.
l Keystone Plates: Keystoneplatemodules allowthe
installation of anyflushmountablekeystone compliant
connector.For details,refer to the FT2A-PLT-KEY-10.
l USBRapidChargers:Provideaconvenientsolutionfor
3
quicklychargingmobile devices atthetable.The
FT2A-CHGR-USBA-BASICincludes twoUSB-A charging
ports. The FT2A-CHGR-USBA/C, usedwithonlyFT2 ELEC
series systems,includes bothUSB-C™ andUSB-Acharging
ports andabacklitsymbolicon. For details,refer to
FT2A-CHGR-USBA-BASICandFT2A-CHGR-USBA/C.
1
WhentwoUSB chargingmodules areused,thesecond
requires the purchase andinstallation of anadditional
power supply(model FT2A-UTK-PWS) beneaththe table.
A maximumofone USBchargingmodule is permittedper
4
row.
l AC Power Outlet Modules:AC poweroutletsareofferedin
NEMAtype modulesavailable for the U.S., Canada,and
Mexico,withone, two, or three outlets per module.
Internationaloutlets are available withoneortwooutlets
permodule. For details refer tothe followingmodules:
FT2A-PWR-US-1, FT2A-PWR-US-1-BASIC,
FT2A-PWR-US-2, FT2A-PWR-US-2-BX, FT2A-PWR-US-3,
FT2A-PWR-EU-1-BASIC,FT2A-PWR-EU-2,
FT2A-PWR-AU-1-BASIC, FT2A-PWR-AU-2,
FT2A-PWR-IS-1-BASIC,FT2A-PWR-IS-2,
FT2A-PWR-IT-1-BASIC,FT2A-PWR-IT-2,
FT2A-PWR-SW-1-BASIC,FT2A-PWR-SW-2,
FT2A-PWR-UK-1-BASIC,FT2A-PWR-UK-2,
FT2A-PWR-UN-1-BASIC,andFT2A-PWR-UN-2.
l BlankPlates:Fill unusedmodule slots withablankplate
1
module. For details,refer to FT2A-PLT-BLANK-10.
l UtilityShelf:A utilityshelf accessory(FT2A-UTK-SHELF)is
available to ease theinstallationofaCrestron
DigitalMedia®transmitter or other interface device
beneath thetable. The shelf attaches to anysideofthe
FlipTopchassisbelowthetable.Twoshelves maybe
installed onopposingsidesofthechassis.
Specifications
ModuleSlots
Maximum 18
Rows 2 rows (9 modules per row)
Connectors (onchassis)
DC Power
NET
Ground
Controls
LidOpen
Power
PowerSupply
(included)
Operating
Power
(2) 2.1 x 5.5 mmDCpower connectors;
24 VDC power inputs
(one per eachrowofmodules)
NOTE: A single FT2A-UTK-PWS power
supplyandY-adaptercable are included to
power bothinputs.A secondpower supply
maybe purchased topowereachinput
separatelyifrequired.
2,4
(1) 3-pin 3.5 detachable terminalblock;
Cresnet® slave port(dataonly)
(1) 6-32 screw;
Chassisgroundlug
(2) Mechanicalpushbutton;
Press to openthecorrespondinglid
Input:1.5Amaximum@ 100-240VAC,
50/60Hz;
Output:2.5 A @ 24VDC
Model: FT2A-UTK-PWS
NOTE:A secondpowersupply,model
FT2A-UTK-PWS,mustbepurchasedand
installed tosupportasecondUSB charging
module. A maximumof one USB charging
module is permittedperrow.
Theoperatingpower is dependentuponthe
AC power outletmodule(s) installed;refer to
theappropriatedomesticandinternational
FT2A-PWR
series formoreinformation.
Environmental
Temperature 32° to112° F (0°to45° C)
Humidity 10% to95% RH (non-condensing)