DO GUIDE
DMPS3-4K-20 0-C/DMPS3-4K- 300 -C
3-Series® 4K DigitalMedia™ Presentation Systems
DO Install the Device
The DMPS3-4K-200-C and DMPS3-4K-300-C can be mounted into a rack or placed onto a at surface.
Mounting into a Rack
The DMPS3-4K-200-C and DMPS3-4K-300-C occupy 3U of rack space.
Using a #1 or #2 Phillips screwdriver, attach the two included rack ears
to the device using the six included #6-32 x 5/16" Phillips screws (three
screws on each side). Then, mount the device into the rack using four
mounting screws (not included).
Placing onto a Flat Surface
When placing the device onto a at surface or stacking it with other
equipment, attach the included feet near the corners on the underside of
the device.
Mounting into a Rack
DO Check the Box
QUANTITY PRODUCT COLOR PART NUMBER
1 Cable, USB 2.0, A - B, 6’ (1.83 m) 20149 6 6
2 Bracket, Rack Ear, 3U 2033588
3 Connector, 2-Pin 2012361
1 Connector, 3-Pin 2003575
4 Connector, 4-Pin 2003576
15 Connector, 5-Pin 2003577
2 Connector, 8-Pin 2003580
4 Foot, 0.5" x 0.5" x 0.23", Adhesive Black 2002389
1 Power Cord, 6' 7" (2 m) 20 0113 4
6 Screw, 6-32 x 5/16", Undercut Head, Phillips Black 2007223
Connecting the DMPS3-4K-300-C
SPEAKER OUTPUT:
®
device
To 4-ohm/8-ohm
stereo speakers or
70-volt/100-volt
mono speakers
From Crestron
PoDM+ power
PoDM+
INPUT PWR:
supply*
SERVICE:
For factory
use only
Power from
line voltage
Ground
IR - SERIAL OUT 1-4:
To IRP2 IR emitter probe
or one-way serial
controlled devices
INPUT 1-4:
From sense output of
digital output devices
(24 volts maximum)
IR IN:
From
CNXRMIRD
IR receiver
RELAY 1-4:
Output to
controllable
devices
COM A and COM B:
To/from
RS-232 devices
NET:
To/from any
Cresnet
DO Connect the Device
Connect the device as required for the application.
Connecting the DMPS3-4K-200-C
INPUT 1-4:
From sense output of
digital output devices
(24 volts maximum)
IR - SERIAL OUT 1-4:
To IRP2 IR emitter probe
or one-way serial
controlled devices
AUD IN 1-5:
From balanced/
unbalanced stereo
line-level analog
audio sources
IR IN:
From
CNXRMIRD
IR receiver
RELAY 1-4:
Output to
controllable
devices
HDMI INPUTS 1-6:
From digital
video/audio sources
COM A and COM B:
RS-232 devices
To/from
MC/LN 1-6:
From balanced
microphone/
line-level
audio sources
To/from any
Cresnet
DM INPUT:
From DM 8G+
output of a DM
transmitter or
other DM device
or from an
®
HDBaseT
device*
NET:
®
®
®
device
SPEAKER OUTPUT:
To 4-ohm/8-ohm
stereo speakers or
70-volt/100-volt
mono speakers
HDMI OUTPUT:
®
To HDMI
display
PoDM+
INPUT PWR:
From Crestron
PoDM+ power
supply*
DM OUTPUT:
To DM 8G+
input of a DM
receiver or
other DM device
or to an
HDBaseT device*
SERVICE:
For factory
use only
CONTROL
SUBNET:
To Crestron
local
network
device*
PROG OUT:
Audio output to
amplier or
amplied speakers
Power from
line voltage
Ground
LAN:
10BASE-T/
100BASE-TX/
1000BASE-T
Ethernet to
LAN
AUX OUT 1-2:
teleconferencing
or codec input
To video
AUD IN 1-5:
From balanced/
unbalanced stereo
line-level analog
audio sources
HDMI INPUTS 1-6:
From digital
video/audio sources
MC/LN 1-6:
From balanced
microphone/
line-level
audio sources
DM INPUTS:
From DM 8G+
output of a DM
transmitter or
other DM device
or from an
HDBaseT device*
HDMI OUTPUTS
1-2:
To HDMI
display
DM OUTPUTS:
To DM 8G+
input of a DM
receiver or
other DM device
or to an
HDBaseT device*
CONTROL
SUBNET:
To Crestron
local
network
device*
PROG OUT:
Audio output to
amplier or
amplied speakers
LAN:
10BASE-T/
100BASE-TX/
1000BASE-T
Ethernet to
LAN
AUX OUT 1-2:
To video
teleconferencing
or codec input
DO Determine the Address of the Device
The DMPS3-4K-200-C and DMPS3-4K-300-C can be addressed using the hostname of the device. The default hostname is DMPS3-xxxxxxxx, where
xxxxxxxx consists of the last eight characters (excluding punctuation) of the MAC address. For example, if the MAC address is 00:10:7F:08:09:AA:05, the
default host name is DMPS3-0809AA05. The MAC address is labeled on the rear panel of the device.
Alternatively, the DMPS3-4K-200-C and DMPS3-4K-300-C can be addressed using the IP address of the device. By default, DHCP is enabled. To set a
static IP address, use any of the following:
• The Crestron Toolbox™ application on a PC that connects to the device via the Ethernet network
NOTE: The Device Discovery Tool can be used to nd the current IP address.
• A USB connection to the COMPUTER port on the front panel of the device
• The front panel LCD display menu

DO Commission the System
Using the web interface, congure the device. To access the web interface, open a web browser and enter either of the following:
hostname/setup (hostname is the hostname of the device)
or
xxx.xxx.xxx.xxx/setup (xxx.xxx.xxx.xxx is the IP address of the device)
The DMPS3-4K-200-C and DMPS3-4K-300-C also provide the built-in DMPS .AV Framework™ Base Program that enables complete system control
without requiring additional programming. For complete details about the capabilities supported by the .AV Framework Base Program, go to www.
crestron.com/avframework.
DO Route the Inputs
To route an input to one or more outputs, use the web interface or the front panel push button controls.
To route the inputs using the front panel push button controls, do the following:
1. Press the ROUTE push putton.
2. Press the INPUT push button that corresponds to the input to be routed.
3. Press the desired OUTPUT push buttons to which the input is to be routed.
4. Press the ENTER push button.
As of the date of manufactu re, the product has bee n tested and found to comply with specications for CE ma rking.
Federal Communications Commission (FCC) Compliance Statement
This device com plies with par t 15 of the FCC Ru les. Operation is sub ject to the follow ing two conditions:
(1) This devic e may not cause harmful interferenc e, and (2) th is device must accept any inter ference rec eived, i ncluding interference that may cau se unde sired opera tion.
CAUTION: Changes or modication s not expressly approved by the ma nufacturer respon sible for compliance could void the user’s autho rity to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a C lass B di gital d evice, p ursuant to par t 15 of the FCC Rules. These limits are designed to provide reasonable protectio n
agains t harmful interference in a reside ntial installation. This equipme nt gene rates, uses and can radiate radio frequency energ y and, if not installed and used i n accordance with the instructions, may
cause harmful inter feren ce to radio communications. H owever, there is no guarantee that inte rference will not occur in a particular installation.
If this equipment does c ause ha rmful inter ference to radi o or television reception, whi ch can be determ ined by tu rning the equipment off and on, the use r is encouraged to try to corre ct the in terferenc e
by one or more of the following m easures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and rece iver.
• Connect the equipment into an outlet on a circui t different from that to which the recei ver is connected.
• Consult the dea ler or an experience d radio/T V technician fo r help.
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
* The DM INPUT and DM OUTPUT ports are PoDM+ PSE (Power Sourcing Equipment) ports and are HDBaseT PoE+ compatible. The CONTROL SUBNET port is a PoE PSE port.
Enabling PoDM+, HDBaseT PoE+, and PoE power sourcing requires connection of the PODM+ INPUT PWR port to an external Crestron power supply (PW-4830DUS or
DM-PSU-3X8-RPS). Any wiring that is connected to a PoDM+, HDBaseT PoE+, or PoE PSE por t is for intrabuilding use only and should not be connected to a line that runs outside of
the building in which the PSE is located.
DMPS3-4K-200-C
DO Learn More
Visit the website for additional information and the latest rmware updates. To learn more about this product, use a QR reader
application on your mobile device to scan the QR image.
Crestron Electronics
15 Volvo Drive, Rockleigh, NJ 07647
888.CRESTRON | www.crestron.com
Rack Mounting Safety Precautions
• Elevated Operating Ambient Temperature: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be
given to ins talling t he equipment in an e nvironm ent comp atible wi th the maximum amb ient temperatur e (Tma) specied by th e manufac turer.
• Re duced Airow: I nstall ation of th e equipm ent in a rack s hould be such that th e amount of airow r equired for safe op eration of the equi pment is not compr omised .
• Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
• Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration
of equipm ent nameplate rat ings should be use d when add ressing this con cern.
• Re liable Earthin g: Reliable ear thing of ra ck-mounte d equipment shou ld be main tained . Partic ular attention s hould be gi ven to supply conne ctions other than d irect co nnections to the br anch circuit (e.g., us e of power strips).
Electrical Connection
“This pr oduct mu st be connected to a n earth ed mains socket-o utlet.”
• Finland: “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.”
• No rway: “Apparatet må ti lkoples jordet sti kkontakt.”
• Swe den: “Apparaten ska ll anslu tas till jo rdat uttag.”
The speci c patents that c over Crestron pro ducts are listed a t http://www.crestron.com/legal/patents. The produ ct warranty ca n be found at www.crestron.com/warranty.
Certa in Crestron pro ducts contain op en source soft ware. For speci c information, ple ase visit www.crestron.com/opensource.
Crestr on, the Crestr on logo, .AV Fram ework, 3-Ser ies, Cresnet, C restron Toolbox , DigitalMedia , DM, and DM 8G+ a re either tradem arks or register ed trademarks o f Crestron Ele ctronics, Inc . in the United Sta tes and/or othe r countries. HD BaseT and the HDB aseT Alliance logo a re either tradem arks
or registe red trademarks of t he HDBaseT Allianc e in the United Stat es and/or other cou ntries. HDMI an d the HDMI logo are ei ther trademarks o r registered trad emarks of HDMI Li censing LLC in the Un ited States and /or other countrie s. Other trademar ks, registered t rademarks, and tr ade names
may be used in th is document to refer t o either the entit ies claiming the marks a nd names or their prod ucts. Crestr on disclaims any prop rietary inter est in the marks and na mes of others. Cre stron is not respo nsible for errors i n typography or ph otography.
This docum ent was written by t he Technical Publicat ions departmen t at Crestron.
©2016 Crestron Electronics, Inc.
DMPS3-4K-300-C
DO GUIDE
DOC. 7791A (2047943 ) 11.16
Specic ations subject to c hange without not ice.