Crestron CNOXM User Manual

CRESTRON CNOXM Oxmoor DCA-2 Interface Module
SYNTAX:
NET.ID < 03 to FE > : CTP-3000 \ CNOXM is represented as a Touchpanel
i1,o1 = <signal name> \ Up_A Channel A Count Up Input i2,o2 = <signal name> \ DOWN_A Channel A Count Down Input i3,o3 = <signal name> \ PRE_A Channel A Preset Input i4,o4 = <signal name> \ PRI_A Channel A Priority Input i5,o5 = <signal name> \ UP_B Channel Count Up Input i6,o6 = <signal name> \ DOWN_B Channel B Count Down Input i7,o7 = <signal name> \ PRE_B Channel B Preset Input i8,o8 = <signal name> \ PRI_B Channel B Priority Input
AI1 = <signal name> \ VOL_A Channel A analog volume setting to DCA-2 AI2 = <signal name> \ VOL_B Channel analog volume setting to DCA-2
AN1 = <signal name> \ VOL_A_FB Ch A analog feedback volume from DCA-2 AN2 = <signal name> \ VOL_B_FB Ch B analog feedback volume from DCA-2
DESCRIPTION:
The Crestron CNOXM is designed to control the Oxmoor DCA-2 Digital Control Attenuator via CRESNET II. The CNOXM displays the volume of both DCA-2 channels on Cresnet-II Touchpanels and bargraph displays. The CNOXM may be thought of as two Oxmoor RC-16 Remote Control Units.
The Oxmoor DCA-2 controls two discrete audio channels, A and B. Volume is controlled in 29 steps of 1.5 dB attenuation from 0 dB to -43.5 dB, with the 30th step for -90 dB "full kill" attenuation. The remote inputs can be "daisy-chained" with multiple RC-16 Remote Control Units.
The Crestron CNOXM has been designed to take advantage of the unique features of the Oxmoor DCA-2 while remaining compatible with the standard SIMPL programming conventions used for the CNVCP-3(2) cards. The SIMPL RAMP and PRESETV analog output signals can drive the CNOXM directly. Note that AV applications may benefit from the standard MXB scaling of 0 to -30 dB as used with the CNVCP-3(2) cards to limit the volume control range in Presentation settings.
The most eye-catching feature of the CNOXM is the perfect tracking of the DCA-2 volume. The CNOXM reads the volume feedback signals directly from the DCA-2. Touchpanels and/or bargraphs always indicate the correct volume. Spinning the knob on an RC-16 connected the CNOXM/DCA-2 ramps the CRESNET II bargraphs in perfect synchronization with the RC­16 LED's. Changing the volume on one unit updates the displays on all units, be it RC-16's or CNOXM's.
Additional features are the "Preset" and "Priority" attenuation levels. The levels for both channels are set on the rear panel. "Preset" is the volume the DCA-2 is set to when it is powered-up and can be recalled at any time. Either or both channels may be recalled to the "Preset" level by momentarily asserting the "Preset" signal inputs. "Priority" is a temporary setting that can be used for paging functions. The volume will return to the previous level after the "Priority" signal input is de­asserted.
REMOTE CONTROL SYSTEMS
1 Doc. 8084
Specifications subject to change without notice. 7.95
CRESTRON CNOXM Oxmoor DCA-2 Interface Module
CABLING AND CONNECTIONS:
Standard 4 or 6-conductor, modular telephone cables are used to interconnect the CNOXM to the DCA-2 and RC-16. (The 4-conductor cables may be used when "Preset" and "Priority" functions are not required). Typically, RJ-12 style 6-conductor cables with RJ-11 size connectors are used. Refer to Oxmoor Model DCA-2 / Model RC-16 Installation and Operation Manual (PN 1700001) for further details.
NOTE: In order for the CNOXM to correctly register feedback, BOTH channels of the DCA-2 must be connected to the CNOXM.
It is possible to control multiple DCA-2 channels with one RC-16 as in a typical room combining system. The SIMPL ABUFFER can drive multiple channel volumes with the volume feedback from one channel. A simple example of a four room combining system uses two DCA-2's, two CNOXM's and four RC-16's. When the rooms are separated, each RC-16 controls the volume of it's respective room. In the combined mode, CNIN inputs enable ABUFFER's to give any of the RC-16's control of all four channel volumes.
Each unique component on the CRESNET II network requires the setting of an identity code (ID CODE). ID CODEs are two­digit hexadecimal numbers, from 10 to FE. The ID CODE of the CNOXM should be set to match the ID CODE specified in the NET.ID statement of the CRESNET II SIMPL program (see syntax above). To set an ID CODE, disconnect power. Notice two miniature rotary switches identified as H and L. These 16- position hexadecimal switches can be set to 0 through F. Using a small screwdriver, rotate the arrow in the center of the switch marked H to point to the first (or most significant) digit or letter of the specified ID CODE. Set the switch marked L to the second ( least significant) digit or letter of the specified ID CODE.
The 4-pin connector marked NET should be wired to the CRESNET II network. Network termination points are available at the control system power supply. Network units may also be daisy-chained together. See the CRESNET II manual section on CNPWS power supplies (Doc. 8017) for wire gauge specifications and connection detail.
The CNOXM has an indicator marked NET POWER. This indicator is lit when 24 volts is supplied to the unit over the network. The indicator marked ID SELECT is lit when the CRESNET II system is communicating with the unit. This indicates that the ID CODE of the CNECI-4 matches the ID CODE of a network unit in the SIMPL program which is currently running in the CRESNET II system.
SPECIFICATIONS:
Enclosure: Black semi-gloss steel Dimensions: 7.5"(D) X 3"(W) X 1.5"(H)
POWER FACTOR:
1.0 watt
REQUIREMENTS:
CRESNET II Workshop Version 4.00 or later. CRESNET II Operating System SR30160.OPS or later.
REMOTE CONTROL SYSTEMS
2 Doc. 8084
Specifications subject to change without notice. 7.95