Crestron CNECI-4A User Manual

Crestron CNECI-4A Electrical Control Interface with AC Operations Guide
This document was prepared and written by the Technical Documentation department at:
15 Volvo Drive
Rockleigh, NJ 07647
1-888-CRESTRON
All brand names, product names, and trademarks are the property of their respective owners.
©1999 Crestron Electronics, Inc.
Crestron CNECI-4A Electrical Control Interface with AC
Contents
Electrical Control Interface with AC: CNECI-4A 1
Description.................................................................................................................................1
Functional Description ................................................................................................1
Physical Description.................................................................................................... 2
Leading Specifications...............................................................................................................3
Setup .......................................................................................................................................... 4
Network Wiring........................................................................................................... 4
Hookup ........................................................................................................................ 5
Identity Code ............................................................................................................... 7
SIMPL Windows Programming ................................................................................................8
How the Program Works............................................................................................. 8
How to Create the Program ....................................................................................... 10
Problem Solving ......................................................................................................................13
Troubleshooting......................................................................................................... 13
Further Inquiries........................................................................................................ 13
Return and Warranty Policies.................................................................................................. 14
Merchandise Returns / Repair Service ......................................................................14
CRESTRON Limited Warranty.................................................................................14
Operations Guide - DOC. 8149 Electrical Control Interface with AC: CNECI-4A i
Crestron CNECI-4A Electrical Control Interface with AC
Electrical Control Interface with AC: CNECI-4A

Description

Functional Description

The Electrical Control Interface with AC, CNECI-4A, is a wall-mounted interface
for AC powered devices such as drapes, screens, and lifts. It is nearly identical to the
CNECI-4 but the exception is that it draws operating power from an AC line that is
independent of Cresnet
to (and regardless of) connection to a Cresnet system.
The CNECI-4A contains four single-pole, double-throw relays for Cresnet system
power control. Using the SIMPL Windows program of the Cresnet system, the relays
are programmed for basic operation or in any combination or sequence. Each of the
relays has two common (COM) terminals (that are electrically connected), one
normally-open (NO) contact, and one normally-closed (NC) contact. A signal from
the Cresnet system (digital high) energizes the relay and a corresponding LED
illuminates.
The LOCAL INPUTS connector is a nine-pin connector, eight input pins and one
ground. A closure from any input pin to ground provides an input to the Cresnet
system. These input closures are programmed to control the relays and/or other
control system function.
The CNECI-4A operates from an AC power feed. The voltage is selectable from
100-125VAC or 220-250VAC. The CNECI-4A may be installed and operated in this
mode via the LOCAL INPUTS by applying a momentary closure to ground to
alternately latch and unlatch the corresponding relays. Upon establishing
communication with the Cresnet system, the LOCAL INPUTS act as control inputs
to the system. Through the NET connector, the +24V Cresnet system power serves
as back-up power to energize the relays if the AC power is not available.
system power. This allows for stand-alone operation prior
If Cresnet system communications are not available while the +24V or the AC
voltage is maintained, the relays may still be operated from LOCAL INPUTS pins 1
through 4. The closure to ground may be supplied from mechanical switches or
Cresnet system I/O cards to operate the relays.
Operations Guide - DOC. 8149 Electrical Control Interface with AC: CNECI-4A 1
Electrical Control Interface with AC Crestron CNECI-4A

Physical Description

The CNECI-4A is housed in a gray, metal enclosure with silk-screened labels on the
front cover. All connections are made to the internal PCB through enclosure conduit
knock-outs that are located on the top, left-side, and bottom of the enclosure. Also
supplied is one 4-position terminal block and one 9-position terminal block. Refer to
the physical view and the PCB components diagrams after this paragraph:
CNECI-4A Physical View
7.00
(17.78 cm)
WARNING
THIS COVER TO BE REMOVED BY QUALIFIED PERSONNEL ONLY.
NO USER SERVICEABLE PARTS UNDER THIS COVER.
NO BRANCH FUSES OR CIRCUIT BREAKERS INSIDE THIS UNIT.
CRESTRON
ELECTRICAL CONTROL INTERFACE CNECI-4A
4-POSITION
TERMINAL
BLOCK
Electronics, Inc. Rockleigh, N.J. 07647
DEPTH = 2.50" (6.35 cm)
9-POSITION
TERMINAL
BLOCK
11. 00
(27.94 cm)
2 Electrical Control Interface with AC: CNECI-4A Operations Guide - DOC. 8149
Loading...
+ 14 hidden pages