Crestron CLW-SWS1 Operating Manual

CLW-SW1, SWS1, & SLVS1(W/A/B)

Introduction

Features and Functions

The CLW-SW1 (-SW1) is a stand-alone wall box switch that can also act as a Cresnet Crestron® control processor. The -SW1 includes two isolated, non-polarized Cresnet wires (plus a ground wire) for connecting to a Cresnet system over a twisted pair wire with shield.
The CLW-SW1 features a three-position mode selection switch. Refer to “Operation ” on page 5 for more information. In the absence of Cresnet communications, the switch can still be used to control a load.
The CLW-SWS1 (-SWS1) is similar to the -SW1 with the added capability of working with a slave unit (CLW-SLVS1) in a multi-switch / single circuit application.
The CLW-SLVS1 (-SLVS1) is a slave unit that when used in conjunction with the -SWS1 acts as an additional switch control point in a multi-switch / single circuit application. It does not connect to a Cresnet system and cannot be used without a -SWS1. The -SLVS1 does not have a mode selection switch and is not programmable. It emulates the operation of the -SWS1 to which it is connected unless the mode selection switch of the master is set to “OFF”.
These switches are available in a variety of colors and textures. The table below shows the availability.
Available Colors/Textures
COLOR/
TEXTURE
White W Not Applicable
Smooth White W-S CW-1-WH
Almond A CW-1-LA
Smooth Almond A-S CW-1-LA
Black B Not Applicable
Smooth Black B-S CW-1-BL
MODEL NUMBER

Specifications

Following are specifications for the -SW1, -SWS1, and
-SLVS1.
CLW-SW1, CLW-SWS1, & CLW-SLVS1 Specifications
SPECIFICATION DETAILS
Power Requirements Line Power, 120 VAC, 60 Hz
Default Net ID SW1: 82
(Continued on next column)
®
device that reports to a
SUFFIX
SWS1: 83
MATCHING LUTRON
FACEPLATE
CLW-SW1, CLW-SWS1, & CLW-SLVS1 Specifications (Continued)
SPECIFICATION DETAILS
Load Type Incandescent, Tungsten Halogen,
2-Series Control System Update File
Load Ratings3
Incandescent / Tungsten Halogen
Magnetic Low Voltage4 -SW1: 1000VA/750W
Neon / Cold Cathode4 -SW1: 1000VA/750W
Electronic Low Voltage -SW1: 1000W
Fluorescent / High Intensity Discharge (HID)
General Purpose Fan -SW1: 3.0A
Minimum Load 40W / 0.5A
Operating Temperature and Humidity
Dimensions and Weight -SW1 and -SWS1:
1. The latest software versions can be obtained from the Crestron
2. Crestron 2-Series control systems include the AV2 and PRO2.
3. Refer to Derating Charts for Multigang Installations on pages 3
4. VA ratings are for input power to the transformer. If you do not
1,2
website. Refer to the NOTE following these footnotes.
Consult the latest Crestron Product Catalog for a complete list of 2-Series control systems.
and 4.
know the input power requirement of the transformer, use the bulb’s wattage rating to determine proper rating.
Fluorescent / High Intensity Discharge (HID), Electronic Low Voltage, Magnetic Low Voltage, Neon / Cold Cathode, General Purpose Fan
Version 3.117 or later
-SW1: 1000W
-SWS1: 1000W
-SLVS1: N/A
-SWS1: 1000VA/750W
-SLVS1: N/A
-SWS1: 1000VA/750W
-SLVS1: N/A
-SWS1: 1000W
-SLVS1: N/A
-SW1: 8A
-SWS1: 8A
-SLVS1: N/A
-SWS1: 3.0A
-SLVS1: N/A
32°F to 104°F (0°C to 40°C ) 10 to 90% Relative Humidity (Non-Condensing)
Height: 4.13 in (10.48 cm) Width: 2.38 in (6.03 cm) Depth: 1.91 in (4.85 cm) Weight: 4.4 oz (0.61 kg)
-SLVS1: Height: 4.13 in (10.48 cm) Width: 1.75 in (4.45 cm) Depth: 1.91 in (4.85 cm) Weight: 3.6 oz (0.50 kg)
NOTE: Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers (CAIP) only. New users may be required to register to obtain access to certain areas of the site (including the FTP site).
Crestron Electronics, Inc. Installation Guide – DOC. 6251B
15 Volvo Drive Rockleigh, NJ 07647 (2009753) Tel: 888.CRESTRON 06.07 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
CLW-SW1, SWS1, & SLVS1(W/A/B)
)

Physical Description

The -SW1 and -SWS1 contain one large pushbutton, a light emitting diode (LED) with software adjustable brightness*, and a three-position slider-switch, shown after this paragraph. Line voltage connections are made at the rear of the switch. Three Class 2 low voltage wires, located on the front of the switch, provide a Cresnet connection to a control system. The wires can be routed to the bottom of the unit for placement outside of the wall box. The -SLVS1 is similar to the -SW1 and -SWS1 but does not have the slider-switch or the Class 2 low voltage wires.
* LED brightness can only be adjusted through Crestron programming
software.
CLW-SW1/SWS1 (L) and CLW-SLVS1 (R) shown in white
Physical view of CLW-SW1/SWS1 (clockwise from top; Top, Side, and Front)
1.75 in
(4.45 cm)
Physical view of CLW-SLVS1 (clockwise from top; Top, Side, and Front)
1.75 in
(4.45 cm)
3.28 in
(8.32 cm)
3.81 in
(9.68 cm)
4.13 in
(10.48 cm)
1.91 in
(4.85 cm)
2.70 in
(6.86 cm
1.50 in
(3.81 cm)
The -SW1, -SWS1, and -SLVS1 mount in a standard wallbox and are covered using a decorative faceplate (not included).

Industry Compliance

This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
2.38 in
(6.03 cm)
3.28 in
(8.32 cm)
3.81 in
(9.68 cm)
(10.48 cm)
4.13 in
1.91 in
(4.85 cm)
1.50 in
(3.81 cm)
2.70 in
(6.86 cm)
E239013
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
2 Stand Alone Wall Box Switch: CLW-SW1, SWS1, & SLVS1 Installation Guide – DOC. 6251B
CLW-SW1, SWS1, & SLVS1(W/A/B)
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.

Important Notes

Read before installation.
Codes: Install in accordance with all local and national electrical codes.
Alternate wiring methods may be used for the Class 2 wiring connection. The 2002 National Electrical Code (Article 725-55) prohibits Class 2 conductors of the -SW1, -SWS1, and -SLVS1 to occupy the same outlet box as the power conductors. The exception is Part D of Section
725.55 of the 2002 National Electrical Code, which allows a device’s power conductors to be installed near (0.25 inch minimum spacing) associated Class 2 conductors in the same outlet box. Consult the 2002 National Electrical Code Handbook and your local electrical inspector before proceeding.
Do not use the supplied butt-splice connectors if the Class 2 conductors are to be installed in the wallbox with the power conductors. Use approved connectors (supplied by others) to make Class 2 connections inside the wallbox.
recommends using 3 ½” deep wallboxes. Several devices can be installed in one wall box (multigang). This requires the removal of side sections (shown below) and the derating of the switching device. For a smooth appearance, one­piece multigang faceplates (not supplied) can be installed.
Other Switch Devices: Mechanical 3- or 4-way switches will not work with the -SW1, -SWS1, or -SLVS1.
Spacing: If mounting one device above another, leave at least 4 ½” vertical space between them.

Multigang Installations

In multigang installations, several controls are grouped horizontally in one wallbox. For a smooth appearance, one-piece multigang faceplates (not supplied) can be installed.
1. When combining controls in a wallbox, remove inner side sections prior to wiring (refer to the following figure).
Inner Sections of Multiganged Switches
REMOVE INNER SECTIONS
CAUTION: TO REDUCE THE RISK OF
OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE.
Wiring: Use copper wire only. For supply connection, use wires rated for at least 75°C.
Load Type: The -SW1, -SWS1, and -SLVS1 are designed for use with permanently installed incandescent, fluorescent (non-dimmable), low voltage, neon/cold cathode, HID, general purpose fan, or tungsten halogen lighting.
Temperature: The -SW1, -SWS1, and -SLVS1 are designed to be used where temperatures are between 32° to 104°F (0° to 40°C).
Wallboxes: Devices mount in standard
Derating Information for Incandescent, Tungsten Halogen, and Electronic Low Voltage Applications
Part Number No Side
-SW1 1000W 600W 400W
-SWS1 1000W 600W 400W
-SLVS1 No Derating Necessary
DO NOT REMOVE OUTER SECTIONS
The load capacity must also be derated. The following charts provide derating information for various applications.
Removed
One Side Removed
Two Sides
Removed
wallboxes. For easy installation, Crestron
Installation Guide – DOC. 6251B Stand Alone Wall Box Dimmer: CLW-SW1, SWS1, & SLVS1 3