Crestron CLW-LSWEX-1GD, CLW-LSWEX-1GU, CLW-LSWEX-2GD Installation And Operation Manual

CLW-LSWEX-1GD/CLW-LSWEX-1GU/CLW-LSWEX-2GD
Wireless Lamp Switch Installation and Operation Guide
Description
The CLW-LSWEX-1GD, CLW-LSWEX-1GU, and CLW-LSWEX-2GD are plug-in switches designed to operate as part of a complete Crestron via the inNET EX the CLW-LSWEX-1GD, CLW-LSWEX-1GU, and CLW-LSWEX-2GD easily act in place of a standard light switch for conventional oor and table lamps.
The CLW-LSWEX-1GD, CLW-LSWEX-1GU, and CLW-LSWEX-2GD are functionally identical. For simplicity within this guide, the term “CLW-LSWEX” is used except where noted.
CLW-LSWEX Specications
SPECIFICATION DETAILS
Power Requirements 120 Vac, 60 Hz
Load Ratings
Incandescent/
Tungsten Halogen
Magnetic Low-Voltage 600 VA / 450 W total*
Environmental
Temperature 32 °F to 104 °F (0 °C to 40 °C)
Humidity 10% to 90% RH (noncondensing)
* The load can be split across both channels in the CLW-LSWEX-2GD.
®
wireless control network. Without the need for additional control wiring,
600 W total*
®
automation system communicating
Additional Resources
Visit the product page on the Crestron website (www.crestron.com) for additional information and the latest rmware updates. Use a QR reader application on your mobile device to scan the QR image.
Installation
NOTE: Before using the CLW-LSWEX, ensure the device is using the latest rmware. Check for the latest rmware for the CLW-LSWEX at www.crestron.com/rmware. Firmware is loaded onto the device using Crestron Toolbox™.
To install the CLW-LSWEX:
1. Plug the CLW-LSWEX into a wall outlet.
2. Use the wall plate screw to secure the CLW-LSWEX to the wall plate (optional).
3. Plug the controlled lamp(s) into the receptacle(s) located on the bottom of the CLW-LSWEX.
4. Acquire the CLW-LSWEX to the inNET EX network.
Operation
Refer to the following diagram when operating the CLW-LSWEX.
Operating the CLW-LSWEX (CLW-LSWEX-2GD Shown)
Button 1: Press this button to toggle load 1 on and off. The green LED lights to indicate that the receptacle is energized.
Load 1 receptacle
Button 2 (CLW-LSWEX-2GD Only): Press this button to toggle load 2 on and off. The green LED lights to indicate that the receptacle is energized.
Load 2 receptacle (CLW-LSWEX-2GD only)
Wireless Communications
The device connects to the Crestron network via the inNET EX communications protocol. Use the procedures outlined below to join or leave an inNET EX network and to verify communications between the device and the control system.
Joining an inNET EX Network
Before a device can be used in a lighting system, it must rst join an inNET EX network. To join an inNET EX network, the device must be acquired by an inNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the inNET EX gateway into Acquire mode from the unit itself or from Crestron Toolbox. Refer to the gateway’s manual at www.crestron.com/manuals for details.
NOTE: In an environment where multiple gateways are installed, only one gateway should be in Acquire mode at any time.
2. Put the device into Acquire mode.
a. Tap button 1 on the device three times, and then press and hold it down
(tap-tap-tap-press+hold) until the LED on the device blinks once (this can take up to 10 seconds).
NOTE: On the CLW-LSWEX-2GD, button 1 or 2 can be used.
b. Release the button to start the acquire process. The top LED blinks slowly to
show that the device is actively scanning the inNET EX network.
• The LED turns on for 5 seconds to show that the device has been successfully
• The LED blinks fast to indicate that the device was not successfully acquired
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer
Leaving an inNET EX Network
To leave an inNET EX network, put the device into Acquire mode, as described in “Joining an inNET EX Network” above, when no gateway is in Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the button three times, and then press and hold it down (tap-tap-tap-press+hold) for up to 2 seconds. The LED blinks to indicate the communications status. Refer to the following table for details.
Turns on for 5 seconds The device is communicating with the control system.
Blinks three times The device is communicating with the gateway, but the
Blinks twice The device is not communicating with the gateway.
Blinks once The device is acquired but is not communicating with
Stays off The device is not joined to the network.
acquired by the infiNET EX network.
by the infiNET EX network. Tap the top button to acknowledge the failure. Ensure the gateway is in Acquire mode and within range before attempting the acquire process again.
to the gateway’s manual for details.
LED COMMUNICATIONS STATUS
gateway is not communicating with the control system.
the network.
Troubleshooting
The following table provides corrective actions for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative.
CLW-LSWEX Troubleshooting
TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION
The lamp does not function.
The lamp cannot be controlled from the control system.
The CLW-LSWEX is not plugged into a live wall outlet.
The lamp is not turned on. Turn on the load locally
The lamp is not connected to the CLW-LSWEX.
The CLW-LSWEX is not acquired to the network.
Verify that the CLW-LSWEX is plugged into an ac outlet and that the circuit breaker is closed. The green LED on the CLW-LSWEX lights when the device is energized.
at the lamp (i.e. at the lamp switch).
Connect the lamp to the CLW-LSWEX.
Acquire the CLW-LSWEX to the network.
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada (IC) Compliance Statement
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device may accept any interference, including interference that may cause undesired operation of the device.
To satisfy RF exposure requirements, this device and its antenna must operate with a separation distance of at least 20 centimeters from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter.
The product warranty can be found at www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at patents.crestron.com.
Certain Crestron products contain open source software. For specic information, please visit www.crestron.com/opensource.
Crestron, the Crestron logo, Crestron Toolbox, inNET EX, and the inNET EX logo are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2015 Crestron Electronics, Inc.
Crestron Electronics, Inc. Installation & Operation Guide - DOC. 6835B
15 Volvo Drive Rockleigh, NJ 07647 (2024689) Tel: 888.CRESTRON 11.15 Fax: 201.767.7576 Specications subject to www.crestron.com change without notice.
Loading...