Crestron CLW-DELVEX-P-GRY-S Installation Guide

CLW-DELVEX-E/CLW-DELVEX-P
Black (HOT)
White (NEU)
remove the button
Gently spread the
button to save the settings.
Step 6: Press each of the
installed buttons on the device.
500 W 400 W 400 W 250 W 400 W400 W
Cameo® Wireless In-Wall ELV Dimmer, 120 V Installation & Operation Guide
Description
The Crestron® CLW-DELVEX-E and CLW-DELVEX-P are Cameo® in-wall ELV dimmers designed for dimming electronic low-voltage lighting, supporting lighting loads such as tungsten-halogen, incandescent, and dimmable LED replacement lamps. Versatile and affordable, the CLW-DELVEX-E and CLW-DELVEX-P feature eld-replaceable, engravable buttons and can be congured with various button layouts and designer colors.
The CLW-DELVEX-E and CLW-DELVEX-P are functionally identical. For simplicity within this guide, the term “CLW-DELVEX-E/P” is used except where noted.
CLW-DELVEX-E/P Specications
SPECIFICATIONS DETAILS
Load Rating Load Type
Maximum Load Minimum Load
Power Requirements 120 Vac, 50/60 Hz, line power
Enclosure 1-gang mountable in a 3-1/2 inch (89 mm) deep
Environmental Temperature Humidity
Electronic low-voltage, LED, incandescent, tungsten-halogen, electronic CFL, 2-wire uorescent ballast
500 VA/watts 10 Watts
A dedicated neutral wire is required.
electrical box; Requires decorator style faceplate (not included)
32° to 104 °F (0° to 40 °C) 10% to 90% RH (noncondensing)
Additional Resources
Visit the product page on the Crestron website (www.crestron.com) for additional information and the latest rmware updates. Use a QR reader application on your mobile device to scan the QR image.
CLW-DELVEX-E CLW-DELVEX-P
Important Notes
WARNING: To avoid re, shock, or death, turn off power at the circuit breaker or fuse and test that power is off before wiring!
WARNING: New installations should be checked for short-circuits prior to installing a CLW-DELVEX-E/P dimmer. With the power off, close the circuit and then restore power. If the lights do not work, or a breaker trips, check and correct the wiring or xture (if necessary). Install the dimmer only when the short is no longer present. The warranty is void if the dimmer is installed and operated with a shorted load.
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, A MOTOR­OPERATED APPLIANCE OR A TRANSFORMER-SUPPLIED APPLIANCE.
ATTENTION: GRADATEURS COMMANDANT UN BALLAST-AFIN DE RÉDUIRE LE RISQUE DE SURCHAUFFE ET LA POSSIBILITÉ D’ENDOMMAGEMENT À D’AUTRES MATÉRIELS, NE PAS INSTALLER POUR COMMANDER UNE PRISE, UN APPAREIL OPÉRÉ DE MOTEUR OU UN APPAREIL ALIMENTÉ PAR UN TRANSFORMATEUR.
NOTE: Observe the following points.
• Codes: Install in accordance with all local and national electrical codes.
• Installation: This product should be installed by a qualied electrician.
• Wiring: Use copper wire only. For supply connections, use wire rated for at least 75 °C.
• Lamp Type: For use with permanently installed incandescent, electronic low-voltage halogen or LED, tungsten-halogen, or dimmable CFL only.
• Temperature: For use where temperatures are between 32° to 104 °F (0° to 40 °C).
• Electrical Boxes: Devices mount in standard electrical boxes. For easy installation, Crestron recommends using 3-1/2 in (89 mm) deep electrical boxes. Several devices can be installed in one electrical box (multigang). This requires derating of the dimming device. For a smooth appearance, one-piece multigang faceplates (not included) can be installed.
• Switches: Mechanical 3- or 4-way switches do not work with CLW-DELVEX-E/P dimmers.
• Spacing: If mounting one device above another, leave at least 4-1/2 in (115 mm) vertical space between them.
• Low-Voltage Applications: Use with electronic low-voltage transformers only.
• Do not use any magnetic low-voltage transformers.
• Operation of a low-voltage circuit with all lamps inoperative or removed may result in current ow in excess of normal levels. To avoid transformer overheating and premature transformer failure, Crestron recommends the following:
> Do not operate low-voltage circuits without operative lamps in place. > Replace burned-out lamps as quickly as possible. > Use transformers that incorporate thermal protection to prevent transformer
failure due to overcurrent.
Installation
Install the CLW-DELVEX-E/P dimmer.
1. Turn the power off at the circuit breaker.
2. Wire the device as shown in the following diagrams. Refer to the table that follows for wire information.
Wire the CLW-DELVEX-P
White (NEU)
HOT
120 V~
Red (LOAD)
Blue (REM) Green (GND)
Wire the CLW-DELVEX-E
HOT
120 V~
Load
To one or more CLW-SLVU-P (optional)
Load
CONNECTION WIRE GAUGE WIRE COLOR
HOT 16 AWG Black
NEU 16 AWG White
LOAD 16 AWG Red
REM 16 AWG Blue
GND 16 AWG Green
3. Push all power wires back into the electrical box and fasten the device to the electrical box with the provided screws.
4. Attach a decorative faceplate.
5. Ensure all buttons, including the air-gap switch and program button, actuate without sticking.
6. Restore power at the circuit breaker.
Changing the Button Assemblies
The button assembly can be removed and replaced with other button assemblies. To replace the button assembly:
1. Squeeze the sides of the bezel near the bezel snaps to remove the button assembly.
Squeeze at arrow points and pull to
assembly.
NOTE: Power to the unit and load is removed automatically when the button assembly is removed.
2. Remove the button from the front of the button assembly.
frame apart to remove the buttons.
3. Insert the new buttons through the front of the bezel and snap them into place. Ensure that the LED strip is on the left side.
Gently spread the frame apart to insert the buttons.
4. Attach the button assembly to the device. Ensure that the LED strip is on the left side.
5. Once power has been restored, press and hold the program button. After 5 seconds, the LEDs associated with the old button layout begin to ash. Continue to hold the button and proceed to step 6.
6. While holding the program button, press all of the buttons in the new layout. The LED next to the pressed button lights.
NOTE: If the rocker switch is installed, press the top and bottom of the rocker.
7. Release the program button to save the settings after all of the buttons have been pressed.
Step 5: Press and hold the program button.
Step 7:
NOTE: Changing the button conguration alters the device’s behavior. Refer to the “Default Button Functions” for details.
Release the program
Multigang Installations
In multigang installations, several devices are grouped horizontally in one electrical box. For a smooth appearance, one-piece multigang faceplates (not included) can be installed.
NOTE: When installing into a multigang box, do not fully tighten devices to the box until the faceplate has been aligned.
The load capacity for each device in the electrical box must be derated. Derating information is shown in the illustration below.
Derating Information for CLW-DELVEX-E/P Dimmers
Operation
NOTE: Before using the CLW-DELVEX-E/P, ensure the device is using the latest rmware. Check for the latest rmware for the CLW-DELVEX-E/P at
www.crestron.com/rmware. Load the rmware onto the device using Crestron
Toolbox™ software. NOTE: The device may be warm during operation. This is normal.
Basic Operation
The CLW-DELVEX-E/P is shipped with a rocker switch already installed. In this conguration, the unit functions as shown below.
NOTE: Operation described in this guide assumes the CLW-DELVEX-E/P is operating in Local mode (without the use of a control system). The device can also operate in Remote mode, in which button behavior is dictated entirely by the control system program.
The LEDs indicate the load level. When all loads are off, the top LED remains dimly lit to act as a night light.
Press to turn the load on. Press and hold to raise the light level.
Press to turn the load off. Press and hold to lower the light level.
Red (LOAD)
Green (GND)
Black (HOT)
Disconnecting Power
the air-gap switch.
indicate the buttons that can
Power to the dimmer and load can be disconnected by pushing on the air-gap switch.
Push here to open
Air-Gap Switch in the
Open Position
NOTE: If the dimmer remains powered after the air-gap is opened, the HOT and DIM terminals have been connected in reverse. Turn off power at the circuit breaker or fuse and adjust the connections.
NOTE: Power to the load is automatically disconnected when the button assembly is removed. For instructions on removing the button assembly, refer to “Changing the Button Assemblies.”
Setting Preset Levels
The CLW-DELVEX-E/P can recall and store up to three presets depending on the installed button conguration.
Set a preset level.
1. Adjust the light level to the desired level.
2. Enter Programming mode by quickly pressing the program button as shown below. Buttons that are capable of storing a preset will ash their LEDs.
NOTE: Programming mode is disabled when the load is off.
3. Press and hold the desired preset button until the LED blinks (approximately two seconds). Release the button to store the new level.
4. If a button is not pressed, the device exits Programming mode after approximately ve seconds.
Step 3:
Preset 1
Preset 2
Preset 3
Off
Hold the button to store a new level.
Step 2: Quickly press the program
button. LEDs ash to
be programmed.
NOTE: A delayed off can be added via control system programming.
Default Button Functions
The gures below illustrate the default functions available for each physical button conguration and press or hold actuation sequence.
Single Button Press
Preset 1
Off
Preset 1
Off
Preset 1
Preset 1
Preset 1
Preset 1
Toggle
Raise
Off
Lower
Raise
Preset 1
Toggle
Lower
Preset 1
Preset 2
Off
Double Button Press (Press Twice within 1/2 Second)
Full On
Full Off
Full On Full On
Full On
Full Off
Full On
Full Off
Full On
Full On
Full On
Full On
Full Off
Single Button Press and Hold (Hold for more than 1/2 second)
Raise
Lower
Raise Raise
Raise
Lower Lower Lower Lower Lower
Raise Raise
Wireless Communications
The device connects to the Crestron network via the inNET EX® communications protocol. Use the procedures outlined below to join or leave an inNET EX network and to verify communications between the device and the control system.
Joining an inNET EX Network
Before a device can be used in a lighting system, it must rst join an inNET EX network by being acquired by an inNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the inNET EX gateway into Acquire mode from the unit itself or from Crestron Toolbox, as described in its manual at www.crestron.com/manuals.
NOTE: In an environment where multiple gateways are installed, only one gateway should be in Acquire mode at any time.
2. Place the device into Acquire mode. a. Tap the top button three times, and then press and hold it down (tap-tap-tap-
press+hold) until the top LEDs on the device ash once (this can take up to 10 seconds).
b. Release the button to start the acquire process. The top LED ashes slowly to
show that the device is actively scanning the inNET EX network.
• The top two LEDs turn on for 5 seconds to show that the device has been successfully acquired to the inNET EX network.
• The top LED ashes quickly to indicate that the device was not successfully acquired by the inNET EX network. Press the top button to acknowledge failure to acquire the inNET EX network. Ensure the gateway is in Acquire mode and within range before attempting the acquire process again.
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer to the gateway’s manual for details.
Leaving an inNET EX Network
To leave an inNET EX network, put the device into Acquire mode, as described in “Joining an inNET EX Network” above, when no gateway is in Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the top button three times and then press and hold it down (tap-tap-tap-press+hold) for up to 2 seconds. The LED ashes to indicate the communications status. Refer to the following table for details.
LED COMMUNICATIONS STATUS
Turns on for 5 seconds The device is communicating with the control system.
Flashes three times The device is not communicating with the gateway, but the
gateway is not communicating with the control system.
Flashes twice The device was previously joined to the network but is not
communicating with the gateway.
Flashes once The device is not joined to the network.
Troubleshooting
The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative.
CLW-DELVEX-E/P Troubleshooting
TROUBLE PROBABLE CAUSE(S) CORRECTIVE ACTION
The dimmer does not function.
The dimmer does not dim to a low level or ickers when dimmed.
The dimmer is not receiving line power.
The load is not operational (e.g., lamps are burned out).
The device is in Remote mode.
The neutral wire is not connected to the dimmer.
The lamps connected may be better suited to an alternate dimming mode.
Verify that the power connections are correct and that the circuit breaker is closed.
Verify that the load is operational and that the air­gap switch is closed.
Check the program to verify the operating mode.
Connect a dedicated neutral wire to the dimmer.
Switch the dimmer to use Alternate Dimming mode. Contact Crestron Technical support or refer to Online Help Answer ID 5520.
This product conforms to UL STD 1472; certied to CSA STD C22.2 No. 184.1.
FCC ID: Contains EROCWD6790
Compliance Statement (Part 15.19 )
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received, including interference that may cause undesired operation.
Warning (Part 15.21)
Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC’s RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
The product warranty can be found at www.crestron.com/warranty. The specic patents that cover Crestron products are listed at www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specic information, please visit
www.crestron.com/opensource.
Crestron, the Crestron logo, Cameo, Crestron Toolbox, and inNET EX are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron. ©2017 Crestron Electronics, Inc.
Crestron Electronics, Inc. Installation & Operation Guide - DOC. 7334E
15 Volvo Drive, Rockleigh, NJ 07647 (2033164) Tel: 888.CRESTRON 11.17 Fax: 201.767.7576 Specications subject to www.crestron.com change without notice.