Crestron CLT-1FAN4 User Manual

CLT- & CLX-1FAN4

Functional Summary

The Crestron 1-Feed, 4-Fan Terminal Block and Module (CLT-1FAN4 and CLX-1FAN4, respectively), are considered a single entity and must be used together. They ship separately to permit termination of the field wiring to the CLT-1FAN4 prior to installation of the CLX-1FAN4, as described in this guide. The module is a capacitive–type fan speed control that connects to the terminal block and controls four ceiling fan motors. The maximum load is 2 amps for any controlled circuit. The module requires 120VAC 60 Hz, 1 phase input voltage. The terminal block and module can be mounted in any Crestron Automation Enclosure (CAEN-Series Enclosures). The terminal block is designed to terminate the circuit feed (HOT and NEUTRAL) and distribute the controlled circuit to the fan(s) (LOAD). An oversize heat sink dissipates heat efficiently. There are LEDs on the module to indicate communication to a Cresnet input power to the module, and output power to the ceiling fan motors.
NOTE: This module is for speed control of a ceiling fan (paddle fan) only. The CLX-1FAN4 cannot change the fan direction. The module provides four speed settings as well as turning the fan off.
NOTE: This module cannot control fans with remote-controlled integrated speed controls.
network,
wide enclosure, be sure to invert units on the right side so that they can be properly wired. Refer to the illustrations below when considering the location of terminal blocks and modules within an enclosure.
NOTE: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure.
Terminal Block & Module Locations (Single-wide Enclosure)
GROUNDING
TERMINAL
BLOCK
TERMINAL
BLOCK
CLX-1FAN4
1 FEED
4 FAN
120VAC 60 Hz
8A MAX
2A MAX/CKT
LINE FAN 1 FAN 2 FAN 3 FAN 4
N IN
N OUT 1 N OUT 2 N OUT 3 N OUT 4
CRESTRON
MODULE

Industry Compliance

This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Terminal Block & Module Locations (Double-wide Enclosure)
TERMINAL BLOCK
(LEFT)
MODULE
TERMINAL BLOCK
(RIGHT)
(E103692)

Installation

The terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electrician, in accordance with all national and local codes.
CRESTRON
CLX-1FAN4
1 FEED
4 FAN
120VAC 60 Hz
8A MAX
2A MAX/CKT
LINE FAN 1 FAN 2 FAN 3 FAN 4
N IN
N OUT 1 N OUT 2 N OUT 3 N OUT 4
CRESTRON
CLX-1FAN4
1 FEED 4 FAN
120VAC 60 Hz
8A MAX
2A MAX/CKT
N OUT 4 N OUT 3 N OUT 2 N OUT 1
N IN
FAN 4 FAN 3 FAN 2 FAN 1
LINE
CAUTION: This equipment is for indoor use only and needs to be air-cooled. Mount in a well­ventilated area. The ambient temperature must be 32°F to 104°F (0°C to 40°C). The relative humidity must be 0% to 90% (non-condensing).
Terminal blocks are installed along the left side of single­wide enclosures and along the outside edges (left and right sides) of double-wide enclosures. Modules are installed along the right side of single-wide enclosures and side-by-side in the center of double-wide enclosures. When installing modules and terminal blocks in a double-
Crestron Electronics, Inc. Installation Guide – DOC. 6032A
15 Volvo Drive Rockleigh, NJ 07647 (2002099) Tel: 888.CRESTRON 10.05 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
GROUNDING TERMINAL BLOCKS
Terminal Block & Module Crestron CLT- & CLX-1FAN4
NOTE: Unless otherwise indicated, the lighting system specified in this guide is modular, requiring assembly in the field by a licensed electrician, in accordance with all national and local codes.
If you require a UL Listed panel, Crestron offers this service through its UL Listed panel shop. This includes complete in factory system configuration and assembly by Crestron for an additional fee.

Terminal Block Installation and Field Wiring

1. Use the two supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the terminal block and the appropriate (left or right) wiring label to the Crestron Automation Enclosure. The wiring label lies beneath the terminal block as shown in the two wiring diagrams on this page.
NOTE: Both left and right wiring labels are provided. The left-side labels are common for both single and double-wide enclosures. The right-side labels are only used in double-wide enclosures since the modules and terminal blocks along the right side must be inverted when mounting.
NOTE: Use copper conductors only – rated 75°C
2. With the circuit breaker turned off, connect the circuit feed (HOT and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the two wiring diagrams on this page). Terminal blocks accept one 14 - 10 AWG wire. Wires should be stripped to ½ inch. Tighten terminal blocks to 9 in-lbs. Do not over tighten.
NOTE: Only one fan may be wired per circuit.
3. Grounding terminal blocks are available in the cabinet for termination of ground wires. Tighten to 35 in-lbs. (14 – 10 AWG), 40 in-lbs. (8 AWG), or 45 in-lbs. (6 – 4 AWG).
Wiring Diagram of the Terminal Block to the Feed and Load(s) (Single-wide and Left Side Double-wide Enclosures)
CLX-1FAN4
1 FEED
4 FAN
120VAC 60 Hz
8A MAX
2A MAX/CKT
HOT
(FROM 15 OR 20 AMP
CIRCUIT BREAKER)
NEUTRAL
GND
GROUNDING
TERMINAL
BLOCK
TO
LOAD(S)
AREA FOR
MODULE
LOCATION
LABEL
LINE FAN 1 FAN 2 FAN 3 FAN 4
N IN N OUT 1 N OUT 2 N OUT 3 N OUT 4
CRESTRON
LEFT SIDE
WIRING LABEL
TERMINAL
BLOCK
Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures)
CLX-1FAN4
1 FEED
4 FAN
120VAC 60 Hz
8A MAX
2A MAX/CKT
N OUT 4 N OUT 3 N OUT 2 N OUT 1
FAN 4 FAN 3 FAN 2 FAN 1
CRESTRON
N IN
LINE
LOAD(S)
AREA FOR
MODULE
LOCATION
LABEL
TO
(FROM 15
OR 20 AMP
BREAKER)
GROUNDING
TERMINAL
BLOCK
GND
NEUTRAL
HOT
CIRCUIT
TERMINAL
BLOCK
RIGHT SIDE
WIRING LABEL
2 Terminal Block & Module: CLT- & CLX-1FAN4 Installation Guide – DOC. 6032A