Crestron C2N-SPWS300 User Manual

Crestron control systems can put a friendly face on any complete integrated AV or automation solution. To support the myriad touchpanels, keypads, and other peripherals that make up a control system, the C2N-SPWS300 provides a convenient and compact centralized power and termination solution.
Cresnet
®
Cresnet is the communications backbone for Crestron touchpanels,
keypads, lighting dimmers, and more. The Cresnet bus is a simple, yet flexible 4-wire network that provides bidirectional communication and 24 Volt DC power for up to 252 Cresnet devices. With cable lengths up to 5000 feet, the Cresnet wiring topology allows almost limitless wiring configurations.
Intelligent Power Distribution—The C2N-SPWS300 is a 300 Watt regulated power supply designed for powering a large network of Cresnet devices. Power is supplied on eight individually managed outputs. Each output is rated for up to 75 Watts, with a total system rating of 300 Watts. Electronic circuit breaker protection is provided on every output, which can be individually monitored and reset from the control system. The voltage level at each output can even be monitored along with ambient temperature and fault status for the complete power supply system.
Sequential Switching—To minimize current inrush upon startup, the C2N-SPWS300 implements sequential switching of its eight outputs. The startup process may be activated automatically when AC power is applied, or when 24 Volts DC is sensed coming from the control system or another power supply.
Cresnet Distribution—Connected to the Master port of any 2-Series Crestron control system, the C2N-SPWS300 provides a total Cresnet distribution solution. Carrying both data and power, the 16 Cresnet ports afford great flexibility for the termination of numerous Cresnet devices, with easy expansion using C2N-HBLOCK termination blocks. It is also ideally designed to enhance the built-in Cresnet distribution capabilities of the PAC2 Professional Automation Control System.
Versatile Mounting Options—The C2N-SPWS300 can be installed in a Crestron CAEN Automation Enclosure using the optional CAEN-MK (sold separately), or rack mounted using the optional C2N-RMAK (sold separately). Alternately, the C2N-SPWS300 may simply be placed on a shelf or mounted to any vertical surface using its built-in mounting flanges.
> 300 Watt regulated power supply
> 8 independently managed outputs
> 16 Cresnet distribution ports
> Cresnet monitoring and control
> Expands the Cresnet power and distribution capabilities of any
2-Series control system
SPECIFICATIONS
Load Ratings
Per Channel: 75 Watts (3.125 Amps) @ 24 Volts DC regulated System Total: 300 Watts (12.5 Amps) @ 24 Volts DC regulated Ripple / Noise: <150 mV Load Protection: Electronic circuit breaker per channel, each rated at 75 watts nominal / 100
watts maximum; 4 Amp, 125V internal fuse; all channels shut off in case of total system overload Sequential Startup: Outputs activate sequentially when power supply system is enabled (see PWR ON, PWR OFF/SLAVE control)
Power Requirements
4 Amps, 100-240 Volts AC, 50/60 Hz
Connections
1 – 8: (16) 4-pin 5mm detachable terminal blocks comprising (2) paralleled Cresnet ports per each of (8) output channels; 24 Volt DC power outputs with Cresnet data pass-thru from NET port
NET: (1) 4-pin 5mm detachable terminal block Ordinarily connects to the Master Cresnet port of a control system Cresnet data ‘Y’ and ‘Z’ terminals pass through to ports 1 – 8 Applying 24V DC to the ‘24’ and ‘G’ terminals enables the power supply system when in “SLAVE” mode
Power: (1) attached input power cable (~1 ft long) with inline IEC320 socket Connects to grounded AC power source using 3-prong power cable or pigtail cable, both provided
Controls
PWR ON, PWR OFF/SLAVE: (1) rocker switch; enables/disables the power supply system if no external DC voltage is applied to the NET port, or selects “SLAVE” mode to allow enabling the power supply system remotely by applying an external 24V DC signal to the NET port
RESET 1 – 8: (8) miniature pushbuttons; each resets its respective output channel, or momentarily disables the channel while held
SYSTEM RESET: (1) miniature pushbutton; resets all output channels sequentially, or momentarily disables all channels while held
SETUP: (1) miniature pushbutton; used for touch-settable ID (TSID)
LED Indicators
PWR 1 – 8: (green) Indicate 24V DC power present at each channel output
OVRLD 1 – 8: (red) Indicate a load in excess of 75 watts on a given channel, channel
output disabled
SYSTEM OVRLD: (red) Indicates a total load in excess of 300 watts on the power supply system, all channels disabled
PWR: (green) Indicates power supply system is enabled
NET: (yellow) Indicates communication with Cresnet system
SETUP: (red) Used for touch-settable ID (TSID)
Environmental
Temperature: 41° to 104°F (5° to 40°C) Humidity: 10% to 90% RH (non-condensing)
Enclosure
Black anodized aluminum, surface mount box with (2) integral mounting flanges
Rack Mount: 3U 19” rack-mountable using C2N-RMAK (sold separately)
CAEN Automation Enclosure: Occupies 1 module space in a single-width enclosure, or
2 side-by-side module spaces in a double-width enclosure; requires CAEN-MK (sold separately)
www.crestron.com |800.237.2041
Crestron C2N-SPWS300
300 Watt Cresnet Power Supply
Crestron C2N-SPWS300 300 Watt Cresnet Power Supply
Crestron Electronics, Inc.
15 Volvo DrivelRockleigh, NJ 07647
Tel: 800.237.2041 / 201.767.3400lFax: 201.767.1903
www.crestron.com
Specifications subject to change without notice. Doc.4922 01/06
All brand names, product names and trademarks are the property of their respective owners.
©2005 Crestron Electronics, Inc.
AVAILABLE ACCESSORIES
C2N-RMAK
Rack Mount Kit
CAEN-MK
CAEN Automation Enclosure Mounting Kit
C2N-HBLOCK
Cresnet Termination Block
C2N-NPA8
Cresnet Network Poll Accelerator
Dimensions
Height: 5.19 in (13.18 cm) Width: 13.25 in (33.66 cm) Depth: 3.29 in (8.36 cm)
Weight
5.3 lbs (2.4 kg)
Bottom View
Front View
Top View
Right Side ViewLeft Side View
13.25 in
(33.66 cm)
5.19 in
(13.18 cm)
3.29 in
(8.36 cm)
Loading...