Crestron C2N-SDC-DC User Manual

Crestron C2N-SDC-DC Shade & Drape DC Motor Controller Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc.
Rockleigh, NJ 07647
1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners.
2005 Crestron Electronics, Inc.
Crestron C2N-SDC-DC Shade & Drape DC Motor Controller
Contents
Shade & Drape DC Motor Controller: C2N-SDC-DC 1
Introduction.................................................................................1
Features & Functions........................................................1
Specifications....................................................................2
Physical Description .........................................................3
Industry Compliance.........................................................5
Setup............................................................................................6
Network Wiring................................................................6
Identity Code ....................................................................8
Hardware Hookup...........................................................10
Installation.................................................................................11
Two-Gang Box Mounting ..............................................11
4x 4 Inch Box Mounting.................................................12
Programming Software .............................................................13
Earliest Version Software Requirements for the PC ......14
Programming with SIMPL Windows.............................14
Uploading and Upgrading.........................................................18
Communication Settings.................................................18
Uploading a SIMPL Windows Program.........................22
Firmware Upgrade..........................................................24
Problem Solving........................................................................26
Troubleshooting..............................................................26
Further Inquiries .............................................................28
Future Updates................................................................28
Return and Warranty Policies ...................................................29
Merchandise Returns / Repair Service ...........................29
CRESTRON Limited Warranty .....................................29
Operations & Installation Guide - DOC. 6373 Contents
i
Crestron C2N-SDC-DC Shade & Drape DC Motor Controller
Shade & Drape DC Motor Controller: C2N-SDC-DC

Introduction

Features & Functions

The Crestron C2N-SDC-DC is a shade and drape DC motor control Cresnet motors that drive shades and drapes. The C2N-SDC-DC is specifically designed for the Cresnet control network and functions as part of a complete Crestron control/automation system. Power for the shade motors is derived from the Cresnet +24 VDC supply. Two 2-pin terminal connectors are provided for + drive and – drive for each motor.
Functional Summary
The C2N-SDC-DC is designed to fit inside and mount to a 2-gang wall box or 4 x 4 x 1.5 inch electrical box, where input power for the two shade or drape motors is derived from Cresnet.
®
slave module designed to control two 2-wire bi-directional DC
Controls two 24 VDC shade or drape motors individually or simultaneously (30 W maximum)
The C2N-SDC-DC mounts on a standard 2-gang or 4-inch square electrical box
Four manual pushbutton controls are provided on the faceplate
Two 2-pin terminal blocks for motor connections can accommodate 30 AWG to 12 AWG wires.
A hardware interlock prevents the motors from being driven in both directions simultaneously. In addition, the firmware implements a
Operations & Installation Guide - DOC. 6373 Shade & Drape DC Motor Controller: C2N-SDC-DC y
1
Shade & Drape DC Motor Controller Crestron C2N-SDC-DC
lockout timer that shuts the motor off for a brief time before allowing the motor to reverse direction. Additional control is available via Cresnet.
Four pushbuttons on the face of the unit allow the motors to be activated without Cresnet control, which is particularly useful when operating the unit locally during installation.

Specifications

The following table summarizes the specifications for the C2N-SDC-DC.
Specifications of the C2N-SDC-DC
SPECIFICATION DETAILS
Cresnet Power Usage 3 Watts (0.125 Amps @ 24 VDC)1 Default ID 23
Control System Update
2, 3, 4
Files
2-Series Control System CNMSX-AV/PRO CNRACKX/-DP CEN/CN-TVAV
Version 3.117.CUZ or later Version 5.14.02X.UPZ or later Version 5.12.63W.UPZ or later
Version 5.12.63V.UPZ or later Firmware Version C2N-SDC-DC.v1.0.upg Motor Input Power 24 VDC from Cresnet Load Types 2-wire Bi-directional DC Motor Maximum Load per Motor 30 W each channel, 30 W total Operating Temperature 41º to 122ºF (5º to 50ºC) Humidity Range 10% to 90% RH Dimensions Height: 4.10 in (10.42 cm)
Width: 4.10 in (10.42 cm) Depth: 1.16 in (2.95 cm)
Weight 0.55 lb (0.25 kg)
1. Does not include power for the motors. For example, add 10 Watts for each Somfy LT28B shade motor. Three Watts are consumed by the C2N-SDC-DC when the motors are not operating. Motor loads may be connected to the C2N-SDC-DC up to the available power remaining on the Crestron power supply. Crestron recommends that the available power be de-rated by a factor of two to allow for the inrush motor current that
y Shade & Drape DC Motor Controller: C2N-SDC-DC Operations & Installation Guide - DOC. 6373
2
Crestron C2N-SDC-DC Shade & Drape DC Motor Controller
occurs when the motors are initially activated. A dedicated power supply for the C2N-SDC-DC and associated motors is recommended.
2. The latest versions can be obtained from the Crestron website. Refer to
NOTE after last footnote.
3. Crestron 2-Series control systems include the AV2 and PRO2. Consult the
latest Crestron Product Catalog for a complete list of 2-Series control systems.
4. Filenames for CNX update files have a UPZ extension. Files on the
website may be .zip or self-extracting .exe files containing the .cuz or .upz file. All can be obtained from the Crestron website. To avoid program problems, make sure you are using the update file with the correct suffix letter (e.g., V, W, X).
NOTE: Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers (CAIP) only. New users may be required to register to obtain access to certain areas of the site (including the FTP site).

Physical Description

The C2N-SDC-DC is a mountable plate with electronic components attached to the rear side. The front side of the plate is labeled and includes; three LEDs that indicate the unit’s status, one Cresnet connector, two connectors for motor control, and all local motor controls. Refer to the following illustrations.
C2N-SDC-DC Front View
Operations & Installation Guide - DOC. 6373 Shade & Drape DC Motor Controller: C2N-SDC-DC y
3
Shade & Drape DC Motor Controller Crestron C2N-SDC-DC
C2N-SDC-DC, Physical Views, Front and Side
C2N-SDC-DC, Physical Views, Rear
y Shade & Drape DC Motor Controller: C2N-SDC-DC Operations & Installation Guide - DOC. 6373
4
Crestron C2N-SDC-DC Shade & Drape DC Motor Controller
Controls and Indicators

Industry Compliance

As of the date of manufacture, the C2N-SDC-DC has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) these devices may not cause harmful interference, and (2) these devices must accept any interference received, including interference that may cause undesired operation.
Operations & Installation Guide - DOC. 6373 Shade & Drape DC Motor Controller: C2N-SDC-DC y
5
Shade & Drape DC Motor Controller Crestron C2N-SDC-DC

Setup

Network Wiring

CAUTION: In order to ensure optimum performance over the full range of your installation topology, Crestron Certified Wire, and only Crestron Certified Wire, should be used. Failure to do so may incur additional charges if support is required to identify performance deficiencies as a result of using improper wire.
CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty.
CAUTION: Provide sufficient power to the system. Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator (http://www.crestron.com/calculators) help calculate how much power is needed for the system.
to
NOTE: When installing network wiring, refer to the latest revision of the wiring diagram(s) appropriate for your specific system configuration, available from the Crestron website.
When calculating the wire gauge for a particular Cresnet run, the length of the run and the Cresnet power usage of each network unit to be connected must be taken into consideration. If Cresnet units are to be daisy-chained on the run, the Cresnet power usage of each network unit to be daisy-chained must be added together to determine the Cresnet power usage of the entire chain. If the unit is a home-run from a Crestron system power supply network port, the Cresnet power usage of that unit is the Cresnet power usage of the entire run. The length of the run in feet and the Cresnet power usage of the run should be used in the following resistance equation to calculate the value on the right side of the equation.
Resistance Equation
R <
40,000
L x P
Where:
R = Resistance (refer to the following table). L = Length of run (or chain) in feet. P = Cresnet power usage of entire run (or chain).
y Shade & Drape DC Motor Controller: C2N-SDC-DC Operations & Installation Guide - DOC. 6373
6
Crestron C2N-SDC-DC Shade & Drape DC Motor Controller
The required wire gauge should be chosen such that the resistance value is less than the value calculated in the resistance equation. Refer to the following table.
Wire Gauge Values
RESISTANCE
(R or Ohms)
(AWG) (MM
WIRE GAUGE
2
)
4 16 1.50
6 18 0.75 10 20 0.50 15 22 0.34 13 Doubled CAT5
8.7 Tripled CAT5
NOTE: All Cresnet wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor, and the other twisted pair is the Y conductor and the Z conductor.
NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to avoid nicking the conductors. Twist together the ends of the wires that share a pin on the network connector, and tin the twisted connection. Apply solder only to the ends of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle. Insert the tinned connection into the Cresnet connector and tighten the retaining screw. Repeat the procedure for the other three conductors.
NOTE: For larger networks (i.e., greater than 28 network devices), it may become necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality throughout the network. Also, for networks with lengthy cable runs, it may be necessary to add a Hub/Repeater after only 20 devices.