Creston CHV-TSTAT, CHV-THSTAT User Manual

Crestron CHV-TSTAT & CHV-THSTAT Thermostats Operations and Installation Guide
Firmware Version v2.061.0018 and Later
This document was prepared and written by the Technical Documentation department at:
15 Volvo Drive
Rockleigh, NJ 07647
1-888-CRESTRON
Regulatory Compliance
As of the date of manufacture, the CHV-TSTAT and CHV-THSTAT has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Industry Canada (IC) Compliance Statement
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
All brand names, product names and trademarks are the property of their respective owners.
©2010 Crestron Electronics, Inc.
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Contents
Quick Installation Reference ....................................................................................................iii
Thermostats: CHV-TSTAT and CHV-THSTAT 1
Introduction ...............................................................................................................................1
Functions and Features................................................................................................ 1
Specifications ..............................................................................................................4
Physical Description.................................................................................................... 5
Setup .......................................................................................................................................... 9
Network Wiring...........................................................................................................9
Identity Code ............................................................................................................... 9
System Connections ..................................................................................................10
Wiring Diagrams .....................................................................................................................11
Separately Powered Two Wire Heat Systems (Powered by an Independent Transformer)
Single Stage Heat Only Systems ............................................................................... 12
Single Stage Heat with Fan Control Systems............................................................ 13
Single Stage Cool Only Systems ............................................................................... 13
Single Stage Heat/Cool with Integrated Control Unit Systems .................................14
Single Stage Heat/Cool with Separate Systems......................................................... 15
Single Stage Heat Pump Systems.............................................................................. 16
Two Stage Heat Pump Systems................................................................................. 17
Slab 1, Slab 2, and Slab 3 (Floor Warming and/or Space Heating) Systems ............18
Slab 4A Two Stage Heat/Single Stage Cool Systems and Slab 5A Floor Warming with Single Stage Space Heat/Cool Systems Slab 4B Two Stage Heat/Single Stage Cool System and Slab 5B Single Stage Heat/Cool with Floor Warming Systems
General Humidifier Connections...............................................................................21
Installation ...............................................................................................................................22
Thermostat Setup..................................................................................................................... 24
Setup Procedure......................................................................................................... 24
Setup Notes................................................................................................................ 24
System Types and Definitions................................................................................... 25
Heat/Cool, 1 or 2 Stages, Forced Air or Radiant .......................................................27
Heat Pump, 1 or 2 Stages, Aux Heat or Dual Fuel .................................................... 31
Slab 1 – Floor Warming Only ...................................................................................35
Slab 2 – Single Stage Space Heat with Slab Maximum ............................................ 39
Slab 3 – Single Stage Heat with Slab Minimum/Maximum...................................... 43
Slab 4A – Two Stage Heat/One Stage Cool with Slab Maximum.............................47
Slab 4B – 2 Stage Heat/1 Stage Cool with Slab Maximum (Heat Pump) .................51
Slab 5A – 1 Stage Heat/Cool with Floor Warming ................................................... 55
Slab 5B – 1 Stage Heat/Cool with Floor Warming (Heat Pump) .............................. 59
Thermostat Operation ..............................................................................................................63
View Button Menus...................................................................................................64
Mode Button Menus.................................................................................................. 65
Programming Software............................................................................................................72
Earliest Version Software Requirements for the PC .................................................72
..............................................................................................................12
.............................................................19
...................................................................20
Operations and Installation Guide – DOC. 8163D Contents i
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
Programming with Crestron SystemBuilder.............................................................. 72
Programming with D3 Pro......................................................................................... 72
Programming with SIMPL Windows ........................................................................73
Example Program ...................................................................................................... 74
Uploading and Upgrading........................................................................................................75
Establishing Communication..................................................................................... 75
Programs and Firmware ............................................................................................76
Program Checks ........................................................................................................76
Problem Solving ...................................................................................................................... 77
Control System Error Log Message Formats ............................................................77
Local Error Messages ................................................................................................78
Troubleshooting......................................................................................................... 79
Check Network Wiring.............................................................................................. 81
Reference Documents................................................................................................ 82
Further Inquiries........................................................................................................ 82
Future Updates ..........................................................................................................82
Appendix A: Glossary ............................................................................................................. 83
Appendix B: About Heat Pumps..............................................................................................85
Return and Warranty Policies.................................................................................................. 86
Merchandise Returns / Repair Service ......................................................................86
CRESTRON Limited Warranty................................................................................. 86
ii Contents Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats

Quick Installation Reference

1. Select a suitable location and run the connecting wires from the heating/cooling system and the Cresnet system. Refer to page 7 for a description of the thermostat connectors.
Refer to page 9 for Network wiring details.
Use the appropriate wiring diagram:
Separately Powered Two Wire Heat Systems (Powered by an Independent Transformer) (Refer to page 12)
Single Stage Heat Only (Refer to page 12)
Single Stage Heat with Fan Control (Refer to page 13)
Single Stage Cool Only (Refer to page 13)
Single Stage Heat/Cool with Integrated Control Unit (Refer to page 14)
Single Stage Heat/Cool with Separate Systems (Refer to page 15)
Single Stage Heat Pump (Refer to page 16)
Two Stage Heat Pump (Refer to page 17)
Slab 1, Slab 2, and Slab 3 (Floor Warming and/or Space Heating) (Refer to page 18)
Slab 4A Two Stage Heat/Single Stage Cool Systems and Slab 5A Floor Warming with Single Stage
Space Heat/Cool (Refer to page 19)
Slab 4B Two Stage Heat/Single Stage Cool System and Slab 5B Single Stage Heat/Cool with Floor Warming (Refer to page 20)
General Humidifier Connections (Refer to page 21)
2. Separate the thermostat from the backplate to expose the connections and mounting holes.
3. Mount the thermostat backplate (60 inches (1.5 meters) above the finished floor) directly to the wall with wall anchors (not provided) and screws (not provided) or to a single-gang box (not provided) mounted horizontally, and connect the wiring. Refer to page 22 for detailed mounting instructions and page 9 for detailed connector information. If using a five-sided box, fill with insulation material to minimize wall air ingress.
4. Install the thermostat on the backplate (Refer to page 22).
5. Setup the thermostat (Refer to page 24).
Heat/Cool Radiant and Forced Air Systems Setup on page 27.
Heat Pump Systems on page 31.
Slab Systems begin on page 35.
6. Configure the thermostat (Refer to “Thermostat Operation” on page 63).
Operations and Installation Guide – DOC. 8163D Contents iii
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Thermostats:

Thermostats: CHV-TSTAT and CHV-THSTAT

CHV-THSTAT

Introduction Introduction

Functions and Features

The CHV-TSTAT and CHV-THSTAT are versatile heating and cooling thermostats designed for one and two stage control of forced air, radiant, and heat pump HVAC systems. The CHV-TSTAT provides temperature control, while the CHV-THSTAT provides temperature control with an integrated humidistat. Relative humidity capability can be added to the CHV-TSTAT through an external remote humidity sensor (sold separately).
Although functional as standalone thermostats, the CHV-TSTAT and CHV-THSTAT deliver greatly enhanced functionality as part of a complete Crestron
®
automation system. The thermostats are available in six different models:
Home
Models
DESCRIPTION MODEL NUMBER COLOR
Heating/Cooling Thermostat
Heating/Cooling and Humidity Thermostat
User adjustable temperature and/or humidity control of one and two-stage heating and cooling systems
Supports seven slab system configurations
128 x 64 Transflective 2.75 inch (70 mm) LCD display
Fahrenheit or Celsius indication
Four-front panel buttons for setup, configuring and temperature/humidity
adjustments
Back light (with each button press) for night viewing
Supports up to four remote temperature and/or temperature/humidity sensors.
Operates as a stand-alone device or in a Cresnet
Extended functionality as a Cresnet device for lighting control, alarms, etc.
CHV-TSTATA Almond
CHV-TSTATB Black
CHV-TSTATW White
CHV-THSTATA Almond
CHV-THSTATB Black
CHV-THSTATW White
®
system
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 1
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
Featuring a large backlit LCD display, the CHV-TSTAT and CHV-THSTAT thermostats are navigable using four simple pushbuttons which provides easy access to indoor and outdoor temperature and humidity readings, setpoint adjustments, system mode and fan status indicators, and setup menus. Climate control features include separate heating, cooling, and humidity setpoints with optional automatic changeover between heating and cooling modes. Adjustable anticipators prevent overshooting the set temperature, and continuous fan operation can be selected when needed for increased circulation.
Multiple Crestron thermostats may be networked via Cresnet to a PAC2, PAC2M, or other 2-Series control system, enabling global temperature and humidity adjustment from any thermostat. Automation functions such as lighting, motorized blinds, or lawn sprinklers can be accessed through two custom remote function pages, and customized text messages can be sent to the LCD display to provide maintenance reminders and other alerts.
Its connection to the control system also enables full control and scheduling of the CHV-TSTAT/CHV-THSTAT from touchpanels and computers throughout the home, and supports extensive flexibility for integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTAT/CHV-THSTAT will remain operable to control the HVAC system.
Optional remote temperature and humidity sensors can be connected to the CHV-TSTAT/CHV-THSTAT for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTAT/CHV-THSTAT to be installed out of view. Outdoor climate can also be monitored, enabling outdoor low­temperature compensation to prevent condensation on windows during cold weather. The CHV-TSTAT/CHV-THSTAT accepts up to four remote temperature sensors, two remote temp/humidity sensors, or a combination of one temp/humidity and two temperature sensors.
Firmware Versions
The new features, and consequent changes to the SIMPL Windows symbol programming, for firmware version 2.0 and later make it incompatible for use with X-generation control processors. In addition, upgrading to release 2.0 and later from a previous release will require a complete re-programming of the thermostat.
Remote Sensors
Firmware version 2.0 and later supports up to four optional remote sensors, two for each input channel: temperature only (CHV-RTS), temperature/humidity (CHV-RTHS), and slab sensor (CHV-RSS) for both thermostats. Information from two sensors that share an input channel is averaged together in the temperature/humidity calculations.
Outdoor conditions, -40º to 170º F (-40º to 77º C), can be imported from the CHV-RSS slab sensor.
For additional information about the sensors, refer to the latest revision of the CHV-RTS & CHV-RTHS Installation Guide (Doc. 8189), and the CHV-RSS Installation Guide (Doc.6229) which are available from the Crestron
www.crestron.com).
(
2 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
®
website
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Heating and Cooling Systems
The CHV-TSTAT and CHV-THSTAT can control the following heating and cooling systems:
One stage heat
One stage heat, one stage cool
One stage heat, one stage cool (heat pump with auxiliary heat)
Two stage heat
Two stage heat, one stage cool
One stage heat, two stage cool
Two stage heat, two stage cool
Two stage heat, two stage cool (heat pump with auxiliary heat)
Wide range cool option suitable for wine cellars or other chilling processes*
Slab settings for heating and floor warming systems*
NOTE: Two Stage Heating – Unlike traditional furnaces that turn on and run at full
capacity with each demand for heating, two-stage heat operates like two separate furnaces to maintain more consistent comfort in your home. The unit starts out running in its first stage, and operates at a fraction of its heating capacity. This reduced capacity is sufficient to warm your home on mild winter days. But when the temperature outside goes very low, the furnace adjusts to full capacity (second stage) to meet the demand for heat within the home.
Two Stage CoolingIn warm weather, the first stage of the cooling equipment
operates at a fraction of the total cooling capacity. On very hot days, the second stage of the cooling equipment energizes, and the cooling system operates at full capacity.
*Firmware version 2.0 or higher.
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 3
Thermostats Crestron CHV-TSTAT and CHV-THSTAT

Specifications

The following table provides a summary of specifications for the CHV-TSTAT and CHV-THSTAT.
CHV-TSTAT and CHV-THSTAT Specifications
SPECIFICATION DETAILS
Measurement Range
Indoor Temperature 0° to 110°F (-18° to 43°C)
Outdoor Temperature -40º to 170º F (-40º to 77º C)
Humidity 0% to 100% RH
1,2
Setpoint Range
Auto Setpoint (union of
38° to 99°F (3° to 37°C) heat and cool setpoint ranges)
Heat only Setpoint 38° to 89°F (3° to 32°C)
Cool only Setpoint 59° to 99°F (15° to 37°C)
Humidity Setpoint 5% to 90 % RH
1,2
Relay Rating 1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
Power Requirements
24V
2 Watts (0.083 Amps) @ 24 Volts AC, supplied
by heating or cooling system
Cresnet Power Usage
<1 Watts (<0.05 Amps @ 24 Volts DC),
required for Cresnet communication only
Display
Type Transflective LCD, backlit
Size 2.75 in (70 mm)
Resolution 128 x 64
Viewing Angle
±50° horizontal (@0° vertical), ±50° vertical
(@0° horizontal)
Default Net ID 2A
Minimum 2-Series Control System Update File
3, 4
Version 3.080.CUZ or later
Environmental
Temperature 41º to 104º F (5º to 40º C)
Humidity 10% to 90% RH (non-condensing)
Enclosure Plastic
Dimensions
Height 3.75 in (96 mm)
Width 5.00 in (127 mm)
Depth 1.04 in (27 mm)
Weight 5.80 oz (165 g)
1. Outdoor temperature/humidity sensing requires additional remote sensors, sold separately.
2. CHV-TSTAT requires additional remote humidity sensor for indoor humidity sensing, sold separately.
3. The latest software versions can be obtained from the Crestron website. Refer to the NOTE following these footnotes.
4. Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest Crestron Product Catalog for a complete list of 2-Series control systems.
1
4 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
NOTE: Crestron software and any files on the website are for authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users may be required to register to obtain access to certain areas of the site (including the FTP site).

Physical Description

This section provides information on the connections, controls and indicators available on your CHV-TSTAT and CHV-THSTAT.
CHV-TSTAT and CHV-THSTAT Physical View
o
68
HEATING HEAT ONLY ON LINE
F
66
o
%
F
43
H1 H2 AX
CHV-TSTAT and CHV-THSTAT Overall Dimensions (Front View)
5.00 in
(127 mm)
1
2
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 5
MODE
VIEW
3
3.75 in
(96 mm)
4
5
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
CHV-TSTAT and CHV-THSTAT Overall Dimensions (Side and Rear Views)
1.04 in
(27 mm)
3.27 in
(84 mm)
CHV-TSTAT and CHV-THSTAT Backplate (Front Cover Removed)
6
7
8
9
TOP
Y
HUM
RHRCG
RS1
RS2
RSR
RSR
RHU
Y/Y1
Y2
24(C)
24(R)
B
W/W1
O
W2
24V
NETWORK
Z
G
6
6 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Connectors, Controls & Indicators
# CONNECTORS,
DESCRIPTION
CONTROLS &
INDICATORS
1 MODE BUTTON
2 VIEW BUTTON
3
4
(DOWN BUTTON)
5 LCD DISPLAY
6
1. Outdoor temperature/humidity sensing requires additional remote sensors, sold separately.
2. CHV-TSTAT requires additional remote humidity sensor for indoor humidity sensing, sold separately.
(UP BUTTON)
CONTROL
CONNECTIONS
(SYSTEM
DEPENDENT)
Access to the user controls (system mode, fan mode, humidifier, Crestron system, and global update)
Access to humidity reading temperature reading messages
Selects user modes and increments selection in setup modes
Selects user modes and decrements selection in setup modes
Displays ambient temperature, humidity, current setpoint, current activity, current function, system information, internal relay status, control system communication errors, firmware download progress, setup parameter/function and values
Terminal blocks
HUM: Energized to RHU during humidity
call
RHU: Reference for humidifier RH: Reference Heat, used for calls to
heating system
RC: Reference Cool, used for calls to
cooling system
G: Fan, energized to RC during call for
fan
Y/Y1: Compressor (stage one), energized
to RC when compressor (or first stage) is run
Y2: Compressor (stage two), energized
to RC on two-stage systems on call for second stage
O: Changeover control, energized to
RC during cooling modes
B: Energized to RC during non-cooling
modes
W/W1: Heat (single stage)/heat (stage one)
energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems
W2: Heat (stage two), energized to RH
during a call for second stage heat in heat/cool systems
1,2
1,2
, outdoor
, and system
(Continued on following page)
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 7
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
Connectors, Controls & Indicators (Continued)
# CONNECTORS,
CONTROLS &
INDICATORS
7
8
9 NETWORK
REMOTE SENSING
CONNECTIONS
(OPTIONAL)
POWER
CONNECTIONS
(REQUIRED)
(OPTIONAL)
DESCRIPTION
Terminal block RSR: Remote Sensor Returns – Common
sensor terminal
RS1: Remote Sensor terminal – Connect
the sensor from RS1 to RSR
RS2: Remote Sensor terminal – Connect
the sensor from RS2 to RSR
Terminal block 24 (C): 24 VAC common terminal supplies
remote 24 VAC power to thermostat
24 (R): 24 VAC reference terminal. Can be
connected to RH or RC by P4 jumper setting, or tied directly to power source (refer to “System Connections” on page 10)
Terminal block, connects to Cresnet control network
24: Power (24 Volts DC) Y: Data Z: Data G: Ground
8 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats

Setup

Network Wiring

When wiring the Cresnet® network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
For networks with 20 or more devices, use a Cresnet Hub/Repeater (CNXHUB)
to maintain signal quality.
CAUTION: Insufficient power can lead to unpredictable results or damage to the
equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (
For more details, refer to “Check Network Wiring” on page 81.

Identity Code

www.crestron.com/calculators).
The Net ID of the CHV-TSTAT/CHV-THSTAT has been factory set to 2A. The Net
IDs of multiple CHV-TSTAT/CHV-THSTAT devices in the same system must be unique. Net IDs are changed from a personal computer (PC) via Crestron Toolbox™ (refer to “Establishing Communication” on page 75).
When setting the Net ID, consider the following:
The Net ID of each unit must match an ID code specified in the SIMPL™ Windows program.
Each network device must have a unique Net ID.
For more details, refer to the Crestron Toolbox help file.
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 9
Thermostats Crestron CHV-TSTAT and CHV-THSTAT

System Connections

NOTE: Installers should have a strong working knowledge of HVAC systems.
CHV-TSTAT and CHV-THSTAT Backplate – Front View With Cover Removed
HUM - Energized (connected) to RHU during humidity call RHU - Reference for humidifier
RSR - Remote Sensor Returns - Common sensor terminal RS1 - Remote Sensor terminal - Connect the sensor from RS1 to RSR
RS2 - Remote Sensor terminal - Connect the sensor from RS2 to RSR 24(C) - 24 VAC common terminal supplies remote 24 VAC power
to thermostat
24(R) - 24 VAC reference terminal. Can be connected to RH or RC
by P4 jumper setting (refer to following page), or tied directly to power source
Network Connection
TOP
Y
Z
RS1
RS2
HUM
RSR
RSR
RHU
24(C)
24(R)
24V
NETWORK
G
for Crestron
Installer Only
RH
RC
Y/Y1
Y2
G
W/W1
B
O
W2
Backplate
W2 - Heat (stage two), energized (connected) to RH during a call for
second stage heat in heat/cool systems
W/W1 - Heat (single stage)/heat (stage one) energized
to RH during a call for heat in heat/cool systems or aux heat in heat pump systems or Slab Heat in Slab Systems.
B - Energized to RC during non-cooling modes O - Changeover control, energized to RC during cooling modes
Y2 - Compressor (stage two), energized to RC on two-stage
systems on call for second stage
Y/Y1 - Compressor (stage one), energized to RC when
compressor (or first stage) is run
G - Fan, energized to RC during call for fan RC - Reference Cool, used for calls to cooling system RH - Reference Heat, used for calls to heating system
10 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats

Wiring Diagrams

The wiring diagrams that follow show connections for the CHV-TSTAT and CHV-THSTAT. The heating or cooling system can supply power to the thermostat, or a separate transformer can supply it. In many installations, spare conductors are
available to supply 24 VAC to the thermostat, using the C (24 VAC common)
connection on the HVAC equipment.
The P4 jumper internally connects either the RH (Reference Heat system) or RC (Reference Cooling system), relieving the installer from connecting a jumper from the 24(R) terminal to the RH or RC terminal.
If power is available from the HVAC system, follow the diagrams for the proper P4 jumper connection.
When power is not available from the HVAC system, a separate transformer, connected between 24(R) and 24(C) terminals, can provide power to the thermostat. When powered by a separate transformer, ensure that the P4 jumper is connected across pins 2 and 3 (No Connection) to prevent damage to the thermostat and the HVAC system.
CAUTION: The P4 Jumper Position on the Circuit Board is critical to proper
operation. Improper P4 jumper position can cause equipment damage. The P4 jumper connects the 24(R) terminal to the RH, or RC connector. Refer to the following illustration.
P4 Jumper Position
P4
1
Connects 24(R) to RH
2
No Connection
3 4
NOTE: Ensure that the power circuits are shut off at the source before connecting
the thermostat. Provide disconnect means and overload protection as required for the power supply.
NOTE: Ensure that the transformer has sufficient power for all the thermostats in
the system, or use multiple transformers. Refer to the power requirements in “Specifications” on page 3.
The following diagrams are examples of connections for heat, heat/cool and one­stage and two-stage heat pump systems, and various slab systems.
NOTE: Use either connector O or B as required, for changeover control.
Connects 24(R) to RC
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 11
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
Separately Powered Two Wire Heat Systems
(Powered by an Independent Transformer)
Independent Transformer Connection – P4 Jumper Connects Pins 2 and 3

Single Stage Heat Only Systems

Single Stage Heat Only System Powered – P4 Jumper Connects Pins 1 and 2
12 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats

Single Stage Heat with Fan Control Systems

Single Stage Heat with Fan Control – P4 Connects Pins 1 and 2 – Additional Jumper Connects RH to RC

Single Stage Cool Only Systems

Single Stage Cool Only – P4 Jumper Connects Pins 3 and 4
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 13
Thermostats Crestron CHV-TSTAT and CHV-THSTAT

Single Stage Heat/Cool with Integrated Control Unit Systems

Single Stage Heat/Cool with Integrated Control Unit – P4 Jumper Connects Pins 1 and 2 – Additional Jumper RH to RC
14 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats

Single Stage Heat/Cool with Separate Systems

Single Stage Heat/Cool with Separate Systems – Heating System Powered – P4 Jumper Connects Pins 1 and 2
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 15
Thermostats Crestron CHV-TSTAT and CHV-THSTAT

Single Stage Heat Pump Systems

Single Stage Heat Pump – P4 Jumper Connects Pins 3 and 4– Additional Jumper RH to RC
16 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats

Two Stage Heat Pump Systems

Two Stage Heat Pump System – P4 Jumper Connects Pins 3 and 4 – Additional Jumper RH to RC
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 17
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
Slab 1, Slab 2, and Slab 3 (Floor Warming and/or Space Heating) Systems
Slab 1, Slab 2, and Slab 3 Systems (Floor Warming and/or Space Heating) – P4 Jumper Connects Pins 1 and 2
18 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Slab 4A Two Stage Heat/Single Stage Cool Systems and Slab 5A Floor Warming with Single Stage Space Heat/Cool Systems
Heat/Cool Style Connections
Slab 4A – P4 Jumper Connects Pins 1 and 2 – Jumper Connects RH to RC
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 19
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
Slab 4B Two Stage Heat/Single Stage Cool System and Slab 5B Single Stage Heat/Cool with Floor Warming Systems
Heat Pump Style Connections
Slab 4B – P4 Jumper Connects Pins 3 and 4 – Additional Jumper Connects RH to RC
20 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats

General Humidifier Connections

Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 21
Thermostats Crestron CHV-TSTAT and CHV-THSTAT

Installation

The location of the thermostat can affect its performance and efficiency. Install the thermostat away from direct sunlight, drafts, doorways, skylights, and windows. Also make sure the thermostat is conveniently located for programming, and do not mount on an exterior wall. The thermostats may be mounted directly to drywall or to a single-gang box.
Thermostats and sensors are mounted 60 inches (1.5 meters) above the finished floor (HVAC industry standard).
Refer to the following illustrations. Do the following to install the CHV-TSTAT or the CHV-THSTAT.
NOTE: When installing directly on drywall, use anchoring screws and hardware.
Make sure the back of the thermostat is flush with drywall and the unit is level.
Required Hardware
Thermostat
Phillips screwdriver (not supplied)
Two 6/32 x 1 inch panhead screws (supplied) for mounting to a
single-gang box
Single-gang box (not supplied)
Wall anchors (not supplied) and screws (not supplied) for
mounting directly to drywall
1. Separate thermostat front plate from back plate (you may need to exert force
when removing the faceplate).
2. Turn off the circuit breaker when connecting power to the thermostat, and
connect wiring as required (wiring goes through center hole on back plate).
NOTE: Ensure the correct position of the P4 jumper; refer to pages 11 through 20.
3. Attach back plate to drywall with screws and anchors (anchor hardware not
provided) 60 inches above the finished floor. Thermostat may also be mounted to a single-gang box mounted horizontally, using the two 6/32 x 1 inch panhead screws provided. If using a five-sided single-gang box, fill with insulation material to minimize wall air ingress. Ensure that the thermostat is level and the ventilation holes in the backplate are not blocked.
4. Note orientation of front plate connection leads and reattach the front plate
on the back plate (make sure front plate snaps in place and no wires are pinched).
NOTE: If replacing an existing thermostat, make note of the wire colors and
positions before removing the old thermostat.
22 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163D
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Installing the CHV-TSTAT and CHV-THSTAT in a Horizontal-Mount Single Gang Box
NOTE: Install insulation (not supplied) in the single gang box to prevent inaccurate readings.
Stud
Panhead 6/32 x 1 in
Installing the CHV-TSTAT and CHV-THSTAT directly to the wall
Mounting Screws (not provided)
Single-gang electrical box (not provided)
Wall Anchors (not provided)
Backplate
Operations and Installation Guide – DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT 23