Crest audio NC-SLM DATASHEET

Power Processing
POWER/OUTPUT MODULE
Modules
FOR CKS, CKV & CKX SERIES
POWER PROCESSING AMPLIFIERS
Load Monitoring, Sequential Turn-On/Off, NexSys®power supply,
NC-SLM
Product Information
The NC-SLM Module fits in the Power/Output bay located on the rear panel of Crest Audio CKS, CKV & CKX Series Power Processing amplifiers. It features full NexSys circuitry for Load Monitoring, Line­Level Output Audio Return and AC Voltage and Current. Load Monitoring is a powerful feature that permits measurement plots to be made of the load (speaker) impedance across frequency ranges on each amp channel. These can be stored and compared to plots run at a later date to detect changes or problems with the load. Activation of the Audio Monitor function by NexSys software places the output of the selected channel on the Audio Return connector. A balanced line is run between amplifiers and back to the control position where audio is mon­itored.
Features
• NexSys compatible • Simple setup, tamper-proof configuration
• Signal chassis ground lift jumper • Sequential turn-on/off initiated by NexSys or a hard closure
• Includes NexSys monitoring of load, line-level output audio and AC voltage and current
• Amplifier output terminals on barrier strip with 0.44" (11mm) screw spacing and 0.32" (8mm) lug spacing
• 5mm 3-pin balanced Phoenix connector for NexSys-initiated line-level output audio return
• With NexSys-initiated STO, user-programmable turn-on and turn-off delay times
AC Voltage & Current Monitor, Audio Return
Due to potential level differences and the effect of the driver’s frequency band and tone, only one channel in a system can be placed on the Audio Return bus at any time.
NC-SLM also provides for NexSys initiation or hard closure activation of Sequential Turn-On/Off (STO). Being self-powered prior to the amplifier power-on, the NC-SLM does not require an external DC sup­ply to activate Sequential Turn-On/Off. The front panel power activation switch must be in the “Remote” position for the NC-SLM to initiate or be part of a Turn-On/Off sequence. NC-SLM requires both an NC-IPN (or any other programmable Input Processor NC Module), and an NC­NXS Module for operation.
NC-SLM connections
Sequential
Turn-On/Off
connection to
other
amplifiers
Off
LISTED 8B42
COMMERCIAL
POWER
AMPLIFIER
120V~60 Hz 15A
On
Com
Com
-
­+
-
-
On
Sequential
Turn-On
In
On Com Off On Com Off
Out
Model NC-SLM
Off
CLASS 2
WIRING MAY
BE USED
Output
A
+
+
B
Signal Ground Lift Jumper
+
+
Audio Return
USA-specification amplifier shown
Architects and Engineers Specifications - NC-SLM.
The module shall plug into Crest Audio CKS or CKV Power Processing amplifiers in the Power/Output bay. The module shall provide NexSys-initiated and hard closure initiated sequential turn-on/off capability for groups of CKS and/or CKV amplifiers. The module shall provide turn-on to the host CKS and/or CKV amplifier and a sequential turn-on output to the next amplifier in the chain. Disconnection of AC power to any number of amplifiers in the chain shall not affect the turn-on sequence capability of all other amplifiers in the chain.
Audio Return
Designed & manufactured in the USA by:
Model Name
CKV 100 CKV 200 CKV 400 CKV 800
CKV 1600
Out
CKV 2400
Network
+–
Output Power
@70.7V
50W 100W 200W 400W 800W
1200W
+–
Crest Audio Inc. 100 Eisenhower Dr. Paramus, New Jersey 07652 USA
Model Name
CKS 100 CKS 200 CKS 400 CKS 800
CKS 800-2 CKS 1200-2 CKS 1600-2
Data
2
3
4
5
6
Output Power
@8/Ch.
50W 100W 200W 400W 400W 600W 800W
Address
F
1
1
E
2
D
3
C
4
B
5
A
6
9
7
8
Hi
Lo
N-Coder Data Port
Model NC-NXS
F
E
D
C
B
A
9
7
8
+
NexSys Bus
The module shall contain the power supplies required for powering the NC-NXS NexSys Network module (if fitted). The module shall include the hardware required for NexSys Load Monitoring and AC voltage and current monitoring. A 5mm 6-pin Phoenix connector shall be provided to receive and pass on the turn-on/turn-off initiation signal. A closure across two of the Phoenix connector terminals on the first amplifier in the chain shall initiate the turn-on/turn-off sequence. The module shall provide outputs for both amplifier channels on barrier strip connectors and a signal ground lift jumper. The module shall be designated the Crest Audio model NC-SLM.
Input A
Input B
+
NC-SLM Power/Output Module
Load Monitoring, Sequential Turn-On/Off, NexSys power supply, AC Voltage & Current Monitor, Audio Return
BLOCK DIAGRAMS
CH A OUT
CH B OUT
AUDIO RETURN OUT
Load Monitor ckt
AUDIO RETURN
OSC
V load I load
CH SEL/GAIN
FROM POWER AMP A
NexSys Module
FROM POWER AMP B
Audio Return Enable OSC Out To
Amp Input
NexSys Module Bus
CONTROL OPTIONS
The following NC-SLM parameters can be controlled/monitored via hard closure or NexSys software.
Hard closure:
Sequential Turn On/Off activation
NexSys computer control:
Sequential Turn On/Off initiation & delay times, load monitor, monitor­ing of audio return, AC mains volt­age, current and wattage.
SPECIFICATIONS
MAINS
TO AMPLIFIER POWER SUPPLY
Pass-thru sequence time: 200ms Connectors: 5mm 6-pin
AC Detect
V line
I line
Phoenix connector
5mm 3-pin Phoenix audio return
connector (600source impedance;
ON COM OFF
ON COM OFF
Opto
OUT
SEQUENTIAL TURN-ON
IN
NexSys On/Off
NexSys Digital Supply
I/D ckt
NexSys Module Bus
40dB of attenuation driven into 600,
referenced from speaker terminals)
Amplifier output barrier strip*
with 0.44" (11mm) center
and 0.32" (8mm) lug space
Controls: Signal chassis
ground lift jumper
*See CKS / CKV power amplifier operator’s manual for power output specifications.
Crest Audio reserves the right to make improvements in manufacturing or design which may affect specification. Crest Audio specification literature is available in electronic form to qualified users.
Contact Crest Audio Inc. for more information. NexSys is a registered trademark of Crest Audio Inc. ©1996 Crest Audio Inc.
(STO)
v. 2.1 4/7/97
*A3300032*
100 Eisenhower Dr., Paramus NJ 07652 USA
Crest Audio Inc.
TEL: 201.909.8700 FAX: 201.909.8744
http://www.crestaudio.com
Printed in USA
Loading...