Crest audio NC-SCO DATASHEET

Power Processing
INPUT PROCESSING MODULE
Modules
FOR CKS, CKV & CKX SERIES
POWER PROCESSING AMPLIFIERS
NC-SCO Stereo Crossover
Product Information
The NC-SCO Module fits in the Input Processing bay located on the rear panel of Crest Audio CKS, CKV & CKX Series Power Processing amplifiers. It is an extremely high quality, fourth-order, two-way elec­tronic stereo crossover that feeds either the LF or HF output of each crossover to the amplifier. The HF and LF crossover frequencies are individually programmable as well as their individual output levels.
Features:
• NexSys compatible, programmable two-way, 24dB per octave electronic crossover
• All parameters (including precision attenuation settings) programmable via NexSys (additional module required) , hand-held N-Coder or N-Coder/PC software
• Balanced inputs on barrier strip connector with .325" (8.3mm) screw center, .270" (6.9mm) lug space
• Removable gain pot knobs for security
• Independent two-way, 4th-order, Linkwitz-Riley filters
• Loop-thru HF and LF outputs for both channels
• Jumper-selectable gain of X20 (26 dB), X40 (32 dB, factory setting), or constant sensitivity for full output at 0dBu (.775V) in.
• Jumper-selectable assignment of high-pass or low-pass output for each amplifier channel
Unbalanced loop-thru barrier strip connectors provide convenient out­puts to other amplifiers. An internal jumper selects between gains of X20 (26 dB), X40 (32 dB), or constant sensitivity for full output at 0dBu (.775V) in. The standard factory setting is for X40 (32dB). Individual channel attenuators are provided with removable knobs for extra securi­ty. The NC-SCO is programmable via NexSys
®
, the hand-held N-Coder or N-Coder/PC software. (NexSys-compatible Power/Output and Network NC modules are required for NexSys implementation.)
NC-SCO connections
N-Coder
OR
PC Lap-Top running
N-Coder/PC software
CLASS 2
WIRING MAY
BE USED
Output
A
+
+
B
Signal Ground Lift Jumper
ISTED 8B42 OMMERCIAL
POWER
AMPLIFIER
V~60 Hz 15A
Sequential
Turn-On
In
On Com
Off
On Com
Off
Out
Model NC-STI
Architects and Engineers Specifications - NC-SCO.
The module shall plug into Crest Audio CKS or CKV Power Processing amplifiers in the Input Processing bay. The module shall be NexSys-compatible. The module shall provide a two-way stereo, 24 dB per octave electronic crossover with programmable HF and LF output levels, HF and LF crossover frequencies, overall output level and HF/LF polarity inversion. The module shall be controlled/programmed either by NexSys via an NC-NXS module (if fit­ted), a hand-held N-Coder or N-Coder/PC software.
Designed & manufactured in the USA by:
Output Power
Model
@70.7V
Name
50W
CKV 100
100W
CKV 200
200W
CKV 400
400W
CKV 800
800W
CKV 1600
1200W
CKV 2400
Network
+
+
NexSys Bus
Crest Audio Inc. 100 Eisenhower Dr. Paramus, New Jersey 07652 USA
Model
Output Power
Name
CKS 100 CKS 200 CKS 400 CKS 800
CKS 800-2 CKS 1200-2 CKS 1600-2
Data
1
2
3
4
5
6
7
Hi
@8/Ch.
50W 100W 200W 400W 400W 600W 800W
Address
F
E
D
C
B
A
9
8
1
2
3
4
5
6
7
8
Lo
High frequency
Crest Audio Revision 1.03E
Low frequency
CKS 200
CKS 400
Out A
N-Coder Data Port
Model NC-NXS
F
E
D
C
B
A
9
HP
LP
Input A
+
Input
Signal A
HP
Input B
+
Input
Signal B
Out B
5
Level
4
6
A
3
7
2
8
1
9
0
Level
10
5
4
6
B
3
7
2
8
1
9
0
10
LP
Model NC-SCO
All programmed settings shall be stored in non-volatile EEPROM memory. A barrier strip input connector shall feed two electronically balanced inputs. Two removable-knob gain pots shall be provided that control the level of each amplifier channel independent of program­ming. High pass and low pass, loop-thru outputs (A&B) shall be available on barrier strip connectors. An input sensitivity/voltage gain jumper shall be provided with selections of 0dBu, X20 and X40. The module shall be designated the Crest Audio model NC-SCO.
NC-SCO Input Processing Module
Stereo Crossover
BLOCK DIAGRAM
HF Out
CH A Daisy Chain
LF Out
HP 1 HP 2
Freq
LP 1 LP 2
Freq Freq
HP 1 HP 2
Freq
LP 1 LP 2
Freq Freq
CH B Daisy Chain
HF Out
LF Out
N-Coder DATA PORT
CH A
IN
+
- G
CH B
IN
+
- G
CONTROL OPTIONS
The following NC-SCO para-
Vosc
meters can be controlled by the hand-held N-Coder, N-
Trim
Gain
Coder/PC software, or via NexSys software.
Freq
Atten
Trim
CH A
Power
Amp
N-Coder:
Channel A& B attenuation, phase reverse, trim and frequen­cy for high & low pass
Gain
CH B
Power
Amp
N-Coder/PC software:
Channel A& B attenuation, phase reverse, muting, trim and frequency for high & low pass
Freq
Trim
Atten
Trim
NexSys computer control:
Channel A& B attenuation, phase reverse, solo, muting, input and output VU metering, trim and frequency for high &
I/F ckt
NexSys® Module Bus
low pass
ID ckt
SPECIFICATIONS
Crossover frequencies: 8Hz-80kHz Input impedance: 50k Dynamic Range: 107dB typ. Common mode rejection: 90dB typ. Frequency response: 20Hz-20kHz, ± .25dB
Programmable gain range: 0 to -83dB
Crest Audio reserves the right to make improvements in manufacturing or design which may affect specification. Crest Audio specification literature is available in electronic form to qualified users.
v. 2.1 4/7/97
Contact Crest Audio Inc. for more information. NexSys is a registered trademark of Crest Audio Inc. ©1996 Crest Audio Inc.
*A3300030*
Voltage gain/input sensitivity: X20 (26 dB),
X40 (32 dB),
or constant sens. for full output at 0dBu (.775V) in
Connectors: Balanced inputs and
unbalanced HP /LP daisy-chain outputs
on barrier strip connectors
with 0.325" (8.3mm) screw center
and 0.270" (6.9mm) lug space,
RJ-14 (‘RJ-11 6-pin’) N-Coder data port
Controls: 2 gain attenuators (w/removable knobs)
Crest Audio Inc.
100 Eisenhower Dr., Paramus NJ 07652 USA
TEL: 201.909.8700 FAX: 201.909.8744
http://www.crestaudio.com
Printed in USA
Loading...