Crest audio NC-MCO DATASHEET

Power Processing
INPUT PROCESSING MODULE
Modules
FOR CKS, CKV & CKX SERIES
POWER PROCESSING AMPLIFIERS
NC-MCO Mono Crossover
Product Information
The NC-MCO Module fits in the Input Processing bay located on the rear panel of Crest Audio CKS, CKV & CKX Series Power Processing amplifiers. It is an extremely high quality, fourth-order, two-way elec­tronic mono crossover that feeds the HF output to channel A of the amplifier and the LF output to channel B. The HF and LF output levels and crossover frequencies are individually programmable. Unbalanced loop-thru barrier strip connectors provide convenient outputs to other amplifiers.
Features:
• NexSys compatible, programmable two-way, 24dB per octave electronic crossover
• Independent two-way, 4th-order, Linkwitz-Riley filters • Loop-thru HF and LF outputs
• Removable gain pot knobs for security • Simple setup, tamper-proof configuration
• All parameters (including precision attenuation settings) programmable via NexSys , hand-held N-Coder or N-Coder/PC software
• Balanced input on barrier strip connector with .325" (8.3mm) screw center, .270" (6.9mm) lug space
Internal Features:
• Jumper-selectable gain of X20 (26 dB), X40 (32 dB, factory setting), or constant sensitivity for full output at 0dBu (.775V) in.
An internal jumper selects between gains of X20 (26 dB), X40 (32 dB), or constant sensitivity for full output at 0dBu (.775V) in. The standard factory setting is for X40 (32dB). Individual channel attenuators are pro­vided with removable knobs for extra security. The NC-MCO is pro­grammable via NexSys
®
, the hand-held N-Coder or N-Coder/PC soft­ware. (NexSys-compatible Power/Output and Network NC modules are required for NexSys implementation.)
NC-MCO connections
PC Lap-Top running
N-Coder/PC software
ASS 2
ING MAY
USED
tput
ignal round ift umper
Designed & manufactured in the USA by:
Model
Output Power
Name
@70.7V
CKV 100
50W
CKV 200
100W
CKV 400
200W
CKV 800
400W
CKV 1600
800W
CKV 2400
1200W
Network
+–
+–
NexSys Bus
Data
Crest Audio Inc. 100 Eisenhower Dr. Paramus, New Jersey 07652 USA
Model
Output Power
Name
@8/Ch.
CKS 100
50W
CKS 200
100W
CKS 400
200W
CKS 800
400W
CKS 800-2
400W
CKS 1200-2
600W
CKS 1600-2
800W
Address
F
F
1
1
E
2
2
D
3
3
C
4
4
B
5
5
A
6
6
9
7
8
7
8
Hi
Lo
Crest Audio Revision 1.03E
N-Coder
OR
To other amplifiers
Daisy Chain
N-Coder Data Port
HP-Out
Model NC-NXS
E
D
C
B
A
9
LP-Out
Input
+
Level
Level
Model NC-MCO
5
4
6
A
3
7
2
8
1
9
0
10
5
4
6
B
3
7
2
8
1
9
0
10
Input
Signal
Architects and Engineers Specifications - NC-MCO.
The module shall plug into Crest Audio CKS or CKV Power Processing amplifiers in the Input Processing bay. The module shall be NexSys-compatible. The module shall provide a two-way, 24 dB per octave electronic crossover with programmable HF and LF output lev­els, HF and LF crossover frequencies, overall output level and HF/LF polarity inversion. The module shall be controlled/programmed either by NexSys via an NC-NXS module (if fitted), a hand-held N-Coder or N-Coder/PC software.
All programmed settings shall be stored in non-volatile EEPROM memory. A barrier strip input connector shall feed one electronically balanced input. Two removable-knob gain pots shall be provided that control the level of each amplifier channel independent of program­ming. High pass and low pass, loop-thru outputs shall be available on barrier strip connec­tors. An internal input sensitivity/voltage gain jumper shall be provided with selections of 0dBu, X20 and X40. The module shall be designated the Crest Audio model NC-MCO.
NC-MCO Input Processing Module
Mono Crossover
BLOCK DIAGRAM
HF Out
LF Out
N-Coder Data Port
HP 1 HP 2
IN
+
- G
Freq
LP 1 LP 2
Freq Freq
I/F ckt
ID ckt
SPECIFICATIONS
Crossover frequencies: 80Hz-8kHz Input impedance: 50k Signal-to-noise ratio: 107dB typ.
Vosc
Gain
CH A
CH B
NexSys® Module Bus
Freq
Trim
Trim
Atten
Gain
Atten
CONTROL OPTIONS
The following NC-MCO parameters can be con­trolled by the hand-held N-Coder, N-Coder/PC software, or via NexSys software.
Common mode rejection: 90dB typ. Frequency response: 20Hz-20kHz, ± .25dB Programmable gain range: 0 to -83dB Voltage gain/input sensitivity: X20 (26 dB)
X40 (32 dB)
or constant sens. for full output at 0dBu (.775V) in
Connectors: Balanced inputs and
unbalanced HP /LP daisy-chain outputs
on barrier strip connectors
with 0.325" (8.3mm) screw center
and 0.270" (6.9mm) lug space,
RJ-14 (‘RJ-11 6-pin’) N-Coder data port
Controls: 2 gain attenuators (w/removable knobs)
Crest Audio reserves the right to make improvements in manufacturing or design which may affect specification. Crest Audio specification literature is available in electronic form to qualified users.
v. 2.1 4/7/97
Contact Crest Audio Inc. for more information. NexSys is a registered trademark of Crest Audio Inc. ©1996 Crest Audio Inc.
*A3300026*
N-Coder:
Channel attenuation, phase reverse, trim and fre­quency for high & low pass
N-Coder/PC software:
Channel attenuation, phase reverse, muting, trim and frequency for high & low pass
NexSys computer control:
Channel attenuation, phase reverse, solo, muting, input and output VU metering, trim and frequency for high & low pass
Crest Audio Inc.
100 Eisenhower Dr., Paramus NJ 07652 USA
TEL: 201.909.8700 FAX: 201.909.8744
http://www.crestaudio.com
Printed in USA
Loading...