Crest audio FXA901 SPECIFICATIONS

FXA901
POWER AMPLIFIER
FXA
Product Description
The Crest Audio FXA901 professional power amplifier is designed to achieve unsurpassed sonic performance and long­term reliability—even when operating under extreme stress—in touring or fixed installation applications.
Absolute sonic accuracy is the hallmark of every Crest amplifier. Bass is solid and defined to the limits of audibility, with ample current reserves delivered by an “over-engineered” power supply and advanced Class AB output circuit design. Wide-bandwidth output devices assure detailed, transparent high frequency response. And, thanks to Crest’s exclusive IGM circuit, the FXA901 will drive 2loads
safely without compromise in per-
formance.
Construction and Quality Control
The FXA901 is built exclusively in Crest’s own USA manufac­turing facility, with internal components selected for premium quality and proven durability. Each modular subassembly is pre­tested, and the assembled FXA901 receives a rigorous “hot room” burn-in before thorough final checkout on precision test equipment.
Power Specifications: Other FXA Series Power Amplifiers
4Stereo FXA601 FXA1201 FXA2401 FXA3601 FXA4801
1kHz, .01% THD+N 250W 600W 900W 1200W 1800W 20Hz-20kHz, 0.1% THD+N 200W 500W 800W 1100W 1700W
FXA901 Features
• Crest’s legendary “overbuilt” power supply
• Toroidal power transformer
• Latest generation of high-speed, wide-bandwidth output devices
• Twin tunnel cooling with back-to-front air flow
• Dual, variable speed DC fans
• Massive, extruded aluminum heat sinks
• Balanced XLR and 1/4-inch (TRS) inputs
• 5-Way Binding Post Outputs
• Stereo/parallel/bridged mono mode selector switch
• Ground lift switch
TourClass
- ACL (Active Clip Limiting) prevents speaker damage with
- IGM (Instantaneous Gain Modulation) monitors speaker
- AutoRamp gradually increases gain to attenuator setting
- TourClass also includes comprehensive thermal manage-
• Input sensitivity selection
• Recessed, stepped attenuators
• Front panel circuit breaker switch
• Modular construction
• Three-year warranty
®
protection circuits:
gentle gain reduction at clip threshold.
loads to detect conditions that may overstress output devices, allowing safe operation into nominal 2imped­ances.
level when amplifier is turned on.
ment, and short circuit, DC voltage, turn-on/off transient, current inrush and sub/ultrasonic input protection.
0 dB
CLIP
-3
SIGNAL
-1
FXA
PROTECT
ACTIVE
Figures are watts per channel, both channels driven.
CLIP
SIGNAL
PROTECT
OFF
ACTIVE
Power Specifications 8Stereo 4Stereo 2Stereo 8Bridged 4Bridged
1kHz, 0.01% THD+N 250W 435W 500W 830W 1100W 20Hz-20kHz, 0.1% THD+N 245W 400W 450W 800W 900W
-6
-3
-10
-30
-80 Ch A
-1
0 dB
-6
-10
-30
-80 Ch B
FXA901 POWER AMPLIFIER
SPECIFICATIONS
1kHz, 0.01% THD+N 20Hz-20kHz, 0.1% THD+N
8Stereo Power 4Stereo Power
2Stereo Power 8Bridged Mono Power 4Bridged Mono Power
Max RMS Output Voltage
(each channel)
Peak Output Voltage (each channel)
Frequency Response (+0 / -0.3dB, 1W/8)
Power Bandwidth (rated power at 4, 1% THD+N)
TourClass®Protection
THD+N
(rated power at 4, 1kHz)
SMPTE IMD (rated power at 8, 60Hz & 7kHz)
Damping Factor (10-400Hz at 8)
Input CMRR (1kHz)
Input Sensitivity (rated power at 8)
Voltage Gain
Input Impedance (balanced/unbalanced)
Hum and Noise
(“A” weighted, full power, 4)
Crosstalk (“A” weighted, full power, 4)
Input Connectors
(per channel)
Output Connectors (per channel)
Filter Storage
Power Supply
(factory configured)
Idle Current Draw 220V
1/8 Power Curr. Draw
(typical music, 220V/4)
1/3 Power Curr. Draw (continuous music, 220V/4)
Max Curr. Draw (circuit breaker rating, 220V/4)
Thermal Emissions (1/8 Power, 4) Thermal Emissions (1/3 Power, 4)
Controls
LED Indicators
(per channel)
Construction
Dimensions
(Height x Width x Depth)
Gross Weight, Net Weight
Warranty
Dealer-Configurable Gain/Sensitivity Options Factory Standard X61 .775V
250W 245W 435W 400W 500W 450W 830W 800W 1000W 900W 58V 82V 20Hz-20kHz, -3dB@135kHz 20Hz-20kHz, -.9dB/+.5dB ACL, IGM, AutoRamp, short circuit, DC voltage, turn-on/off transient, current inrush, sub/ultrasonic input. <0.01% <0.01% 550:1 > - 60dB
0.775V standard (see table below) X61 standard (see table below) >20k/>10k
-105dB > - 60 dB
Class
AB Female XLR (pin 2+, dealer configurable for pin 3+), TRS (tip+) 5-way output binding posts 27,200 µF 100V-240V, 50-60Hz
0.7A
3.4A
5.0A
8.0A 2030 BTU/hr 2726 BTU/hr
Cooling
Back-to-front via 2 rear panel mounted variable-speed DC fans (filters removable without tools) Front Panel: 2 attenuators Rear Panel: signal ground lift switch, mode select switch Clip/Limit, Signal, Temp/DC, Active Steel chassis, 16 gauge. Double thickness in rack ear areas.
3.5" x 19" x 17.85" / 89 x 483 x 454mm 46 lbs. / 20.88 kg., 41 lbs. / 18.61 kg. 3 years, parts & labor
Gain Sens
Option 1 X40 1.12V Option 2 X20 2.24V
Architect’s & Engineer’s Specifications
The power amplifier shall have two channels. At 8 ohms, 20Hz
- 20kHz, 0.1% THD+N, it shall deliver a minimum of 245 watts per channel. At 4 ohms, 20Hz - 20kHz, 0.1% THD+N, it shall deliver a minimum of 400 watts per channel. In bridged mono mode with an 8 ohm load, 20Hz - 20kHz, 0.1% THD+N, it shall deliver a minimum of 800 watts. Two rear panel mounted variable speed DC fans (filters detachable without tools) shall provide back to front air flow through the chassis. The amplifier shall have circuitry to protect itself from output short circuits, thermal overload or other adverse load condi­tions. The amplifier shall protect speaker loads from DC volt­age on outputs. The amplifier shall have active clip limiting and impedance sensing circuitry. Output relays shall protect the speakers from amplifier failure. Each channel shall have a standard (factory-set) input sensitiv­ity of 0.775 Volts, and shall be fitted with an internal jumper which allows the gain to be altered to X20 or X40. The hum and noise level shall be 105 dB below rated output, “A” weighted. SMPTE IMD shall be less than 0.01% at rated power, 60Hz and 7kHz. The amplifier shall have a class AB output stage. The frequency response shall be 20Hz-20kHz, +0, -0.3dB (1W/8). The amplifier will operate at 100V-240V, 50-60 Hz AC (config­ured at factory). Maximum current draw shall not exceed 8 amperes at 220VAC (limited by front panel breaker for bench tests). Front panel indicators shall include Active, Protect, Signal, and Clip LED’s for each channel. Front panel attenuators shall be recessed and detented. Rear panel input connectors shall be female TRS and XLR type, internally dealer-configurable for pin 2 (factory setting) or pin 3 positive. Output terminations shall be 5-way output binding posts. A ground lift switch and a Stereo/ Parallel/Bridged Mono mode operation switch shall be provid­ed. A rear-panel IEC AC mains socket (with power cord) or single AC mains cord having an appropriate AC plug for the intended operating voltage shall be provided (market dependent). The packaging of the amplifier shall allow for standard rack mounting without requiring space between similar units. Optional rack mount handles will be available. Dimensions shall be 19" (483mm) wide, 3.5" (89mm) high and 17.85" (454mm) deep. The amplifier shall weigh 41 lbs. (18.61 kg.) net, and shall be designated the Crest Audio model FXA901.
Rear View
v. 1.0 11/6/97
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS : RISQUE DE CHOC ÉLECTRIQUE—NE PAS OUVRIR
WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
ATTENTION! POUR ÉVITER LE RISQUE D'INCENDIE OU DE CHOC
ÉLECTRIQUE, NE PLACEZ PAS CET APPAREIL SOUS LA PLUIE OU Á
L'HUMIDITÉ
Power figures are watts per channel, both channels driven. Crest Audio reserves the right to make improvements in manufacturing or design which may affect specification.
+ +
+
A
A B
B
A
AB
A
A
B
A
B
B
A
A
+
••
B
Designed & manufactured in the USA by:
Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
2+
1
3-
100 Eisenhower Dr., Paramus NJ 07652 USA
TEL: 201.909.8700 FAX: 201.909.8744
http://www.crestaudio.com
Crest Audio Inc.
Loading...