Decades of proven performance, reliability and intelligence converge in the
Crest Audio CKd
design made famous by the Crest Audio Pro 200
™
Series, combining the legendary overbuilt power supply
™
with NexSys® networking
functionality and an ultra-lightweight class D topology. The design centers
around an ultra-high effi ciency amplifi er output circuit which reduces weight
while increasing output power, reliability and thermal effi ciency.
The CKd Series offers four multi-channel models to meet the needs of
demanding audio installations. The CKd 1208 and CKd 1204 provide 1,250
watts per channel in eight and four channels, respectively, while the CKd
608 and CKd 604 provide 625 watts per channel in eight and four channels
respectively. Each amplifi er channel will operate to rated power in direct 70volt, 100-volt, 8-ohm or 4-ohm modes, confi gurable per channel.
CKd amplifi ers are networkable through the new Crest Audio Nx Dante-8
NexSys control module to the Crest Audio NexSys 5 and Peavey
MediaMatrix
®
NWare™ software programs for advanced control and audio
™
®
routing. The Nx Dante-8 module fi ts into the rear bay of CKd Series power
amps and supports all NexSys functions, DSP functions and Dante digital
audio I/O via 1 Gigabit Ethernet connection.
A Control Voltage input is included on each channel to allow external gain
control, while the Fault output on each channel allows the CKd power amps
to be wired to other monitoring systems. In addition, users can conserve
energy by disabling channels that are not in use.
The CKd Series includes Crest Audio’s exclusive ACL
™
(Active Clip Limiting),
which automatically reduces gain at the onset of clipping to prevent amplifi er
and load damage, and IGM
™
(Instantaneous Gain Modulation), which
monitors load current to protect against overloading.
• Four multi-channel models: CKd-604, CKd-608, CKd-1204 and CKd-1208
• Ultra-lightweight class D topology
• CKd-1208 and CKd-1204 provide 1,250 watts per channel in eight and
four channels respectively
• CKd-608 and CKd-604 provide 625 watts per channel in eight and four
channels respectively
• Each amplifi er channel will operate to rated power in direct 70-volt, 100-
volt, 8-ohm or 4-ohm modes, confi gurable per channel
• Networkable through Crest Audio
to the Crest Audio NexSys 5 and Peavey MediaMatrix
®
Nx Dante-8™ NexSys control module
®
NWare™ software
programs for advanced control and audio routing
• Control Voltage input is included on each channel to allow external gain
control
• Fault output on each channel allows CKd power amps to be wired to
other monitoring system
• CKd amplifers have the option to conserve energy by disabling
channels that are not in use
• Crest Audio’s exclusive ACL
™
(Instantaneous Gain Modulation) to protect against overloading
• IGM
™
(Active Clip Limiting)
CKd™ 1208 CKd™ 608 Ckd™ 1204 CKd™ 604
Rated Power @ 4 ohms (1kHz single channel driven) 1,400 watts per channel at <0.15% 750 watts per channel at <0.15% 1,400 watts per channel at <0.15% 750 watts per channel at <0.15%
Rated Power @ 8 ohms (1kHz single channel driven) 1,300 watts per channel at <0.1% 750 watts per channel at <0.1% 1,300 watts per channel at <0.1% 750 watts per channel at <0.1%
Rated Power @ 70.7 volts (1kHz single channel driven) 1,250 watts per channel at <0.15% 625 watts per channel at <0.15% 1,250 watts per channel at <0.15% 625 watts per channel at <0.15%
Rated Power @ 100 volts (1kHz single channel driven) 1,250 watts per channel at <0.1% 625 watts per channel at <0.1% 1,250 watts per channel at <0.1% 625 watts per channel at <0.1%
Rated Power @ 4 ohms (all ch driven 50% duty cycle*) 1,250 watts per channel at 1kHz 650 watts per channel at 1kHz 1,250 watts per channel at 1kHz 650 watts per channel at 1kHz
Rated Power @ 8 ohms (all ch driven 50% duty cycle*) 1,250 watts per channel at 1kHz 650 watts per channel at 1kHz 1,250 watts per channel at 1kHz 650 watts per channel at 1kHz
Rated Power @ 70.7 volts (all ch driven 50% duty cycle*) 1,250 watts per channel at 1kHz 625 watts per channel at 1kHz 1,250 watts per channel at 1kHz 625 watts per channel at 1kHz
Rated Power @ 100 volts (all ch driven 50% duty cycle*) 1,250 watts per channel at 1kHz 625 watts per channel at 1kHz 1,250 watts per channel at 1kHz 625 watts per channel at 1kHz
Minimum Load Impedance 4 ohms 4 ohms 4 ohms 4 ohms
Frequency Response (-.5 dB @ 1 watt (8 ohm load) 10 Hz - 20 kHz 10 Hz - 20 kHz 10 Hz - 20 kHz 10 Hz - 20 kHz
Damping Factor (8 ohms) >200:1 @ 20 Hz - 1 kHz >150:1 @ 20 Hz - 1 kHz >200:1 @ 20 Hz - 1 kHz >150:1 @ 20 Hz - 1 kHz
Input CMRR < -75 dB at 1kHz < -75 dB at 1kHz < -75 dB at 1kHz < -75 dB at 1kHz
Voltage Gain (Low Z) x 40 (32.0 dB) x 40 (32.0 dB) x 40 (32.0 dB) x 40 (32.0 dB)
Voltage Gain (70v/100v) x 50 (34.0 dB) x 50 (34.0 dB) x 50 (34.0 dB) x 50 (34.0 dB)
High Pass Filter 70 Hz, 3rd order HPF 70 Hz, 3rd order HPF 70 Hz, 3rd order HPF 70 Hz, 3rd order HPF
Input Sensitivity (Low Z) 1.9V for 1 kHz 4-ohm rated power 1.27V for 1 kHz 4-ohm rated power 1.9V for 1 kHz 4-ohm rated power 1.27V for 1 kHz 4-ohm rated power
2.55V for 1 kHz 8-ohm rated power 1.8V for 1 kHz 8-ohm rated power 2.55V for 1 kHz 8-ohm rated power 1.8V for 1 kHz 8-ohm rated power
Input Sensitivity (70v/100v) 1.4V for 1 kHz (70V) 4-ohm rated power 1.4V for 1 kHz (70V) 4-ohm rated power 1.4V for 1 kHz (70V) 4-ohm rated power 1.4V for 1 kHz (70V) 4-ohm rated power
2.5V for 1 kHz (100V) 8-ohm rated power 2.5V for 1 kHz (100V) 8-ohm rated power 2.5V for 1 kHz (100V) 8-ohm rated power 2.5V for 1 kHz (100V) 8-ohm rated power
Input Impedance 20K Ohms balanced, 10K Ohms unbalanced 20K Ohms balanced, 10K Ohms unbalanced 20K Ohms balanced, 10K Ohms unbalanced 20K Ohms balanced, 10K Ohms unbalanced
Noise and Hum > - 95dB, “A” weighted reference > - 95dB, “A” weighted reference > - 95dB, “A” weighted reference > - 95dB, “A” weighted reference
to rated power @ 8 ohms to rated power @ 8 ohms to rated power @ 8 ohms to rated power @ 8 ohms
CURRENT CONSUMPTION ALL CHANNELS
Idle: 200 watts, 400VA 120 watts, 240VA 120 watts, 240VA 85 watts, 170VA
1/8 Power 8 ohms / 4 ohms: 1.6kW, 2.45kVA / 1.72kW, 2.7kVA .96kW, 1.47kVA / 1kW, 1.62kVA .96kW, 1.47kVA / 1kW, 1.62kVA .67kW, 1kVA / 700W, 1.14kVA
1/3 Power: 4kW, 6kVA / 4.4kW, 6.6kVA 2.4kW, 3.6kVA / 2.64kW, 4kVA 2.4kW, 3.6kVA / 2.64kW, 4kVA 1.7kW, 2.5kVA / 1.85kW, 2.8kVA
THERMAL EMISSION ALL CHANNELS (btu/hour)
Idle: 677 btu/hr 406 btu/hr 406 btu/hr 285 btu/hr
1/8 Power 8 ohms / 4 ohms: 1060 / 1170 636 / 700 636 / 700 445 / 490
1/3 Power 8 ohms / 4 ohms: 2115 / 2330 1270 / 1400 1270 / 1400 890 / 980
Cooling Temperature dependent variable speed 80mm DC fan
CONTROLS
Front: On/Standby/Remote AC Switch, 120V: two independent 21A circuit breakers, 230V: two independent 12A circuit breakers (per 4 channels)
Rear: 8 channel input signal attenuators, 8 channel 100V/70V/LowZ selection switches, two 4 channel input signal attenuators, 4 channel 100V/70V/LowZ selection switches,
3-position connectors for STO In and STO Out, 8 Fault Relay outputs (NO/NC), 8 Control two 3-position connectors for STO In and STO Out, 4 Fault Relay outputs (NO/NC), 4 Control
Voltage inputs, NexSys module bay Voltage inputs, NexSys module bay
INDICATOR LEDS
Front panel: 8 Mute, 8 Fault, 8 ACL/IGM, 8 Signal, 8 Active, 1 Power 4 Mute, 4 Fault, 4 ACL/IGM, 4 Signal, 4 Active, 1 Power
Rear panel: 8 Mute, 8 Fault, 8 ACL/IGM, 8 Signal, 8 Active, 1 Power 4 Mute, 4 Fault, 4 ACL/IGM, 4 Signal, 4 Active, 1 Power
Protection (per channel) Over-temperature, DC, subsonic, incorrect loads, short-circuit, over-current
Unit Protection Over/Under AC Voltage, Fan operation
CONNECTORS
Input: Eight 3-position Euro-style detachable terminal blocks Four 3-position Euro-style detachable terminal blocks
Output: Four 4-position barrier strip terminal blocks with screws Two 4-position barrier strip terminal blocks with screws
Construction 14-gauge aluminum reinforced chassis with 12-gauge steel rack ears
DIMENSIONS
Height: 3.48” (8.84 cm), 2 EIA rack spaces 3.48” (8.84 cm), 2 EIA rack spaces 3.48” (8.84 cm), 2 EIA rack spaces 3.48” (8.84 cm), 2 EIA rack spaces
Width (front): 19.00” (48.26 cm) 19.00” (48.26 cm) 19.00” (48.26 cm) 19.00” (48.26 cm)
Width (rear): 17.25” (43.82 cm) 17.25” (43.82 cm) 17.25” (43.82 cm) 17.25” (43.82 cm)
Overall depth: 20.30” (51.56 cm) 20.30” (51.56 cm) 20.30” (51.56 cm) 20.30” (51.56 cm)
Mounting depth: 19.70” (50.04 cm) behind front rack ears 19.70” (50.04 cm) behind front rack ears 19.70” (50.04 cm) behind front rack ears 19.70” (50.04 cm) behind front rack ears
Gross Weight 29.6 lbs (13.43 kg) 29.6 lbs (13.43 kg) 22 lbs (9.98 kg) 22 lbs (9.98 kg)
Net Weight 34.6 lbs (15.7 kg) 34.6 lbs (15.7 kg) 25 lbs (11.4 kg) 25 lbs (11.4 kg)
Power Requirements 120 VAC 60 Hz or 230 VAC 50 Hz
* repetitive 1kHz cycles 50ms onset of clip and 50ms at 1/8 power
Crest Audio CKd 1208, 1204, 608 and 604 Power Amplifi ers
The multi-channel power amplifi ers shall be available in hardware confi gurations of eight and four analog input channels and powered output channels. Each channel output shall be
individually selectable as 8-ohm or 4-ohm low-impedance, or 70-volt or 100-volt constant voltage outputs. Input signals shall be connected via eight 3-position Euro-style detachable
terminal blocks, and may be confi gured as balanced or unbalanced inputs. Amplifi ed outputs shall be connected via four 4-position barrier strip terminal blocks with screw terminals.
Each model confi guration shall be capable of accepting and hosting either of two networked modules to support connection of CobraNet or Dante networked audio transport streams of
four or eight channels. Audio, control and monitoring signals shall be conducted to and from the power amplifi er via Ethernet connections.
The power amplifi er sections shall be of a highly effi cient and lightweight Class D amplifi er design yielding 1,250 watts per channel or 650 watts per channel at 1kHZ with all channels
driven at 50% duty cycle into 4-ohms or 8-ohms or 70.7 volts or 100 volts. Frequency response at 1 watt under an 8-ohm load shall be 10 Hz to 20 kHz.
Control voltage inputs shall be provided for each channel to allow for external gain control. Fault outputs on each channel shall be provided to allow monitoring of the operation of
individual channels. Instantaneous Gain Modulation shall provide overload protection for each channel.
The multi-channel power amplifi ers shall be the Crest Audio CKd-1208, CKd-1204, CKd-608 and CKd-604 power amplifi ers.