Cres Cor IFW-63 Service Manual

Page 1
5925 Heisley Road Mentor, OH 44060-1833
877/CRES COR (273-7267) 440/350-1100
Fax: 440/350-7267 www.crescor.com
for PULL-DOWN INFRA-RED MODELS IFW-63 SERIES
ELECTRICAL SPECIFICATIONS:
120 Volts; 250 Watts; 2 Amps.
240 Volts; 275 Watts; 1 Amp.
UL AND CSA REQUIRE:
Wires of warmer are to be connected to
75°C wire.
Wires to be installed with conduit
Warmers are not to be installed closer
than 1” from a wall.
Warmers cannot be closer than 16”
above a combustible surface
HOW TO INSTALL: (See Figure)
NOTE: Outlet box (7) and screws (5) are to be furnished by customer.
1. Pull canopy (2) down over coil cord.
2. Attach ground wire from the ceiling to the “GND” hold in the plate (4) with screws (6).
3. Wire the warmer leads to the outlet box (7) with screws (5).
4. Attach plate (4) to the outlet box (7) with screws (5).
Infra-red Lamps
IFW 63 Series
Rev. 5 (7/02) Page 1 of 1
REPLACEMENT PARTS:
Lamp, Red (120V) 0820-001 Lamp, Red (120V), Shatterproof 0820-001-SP Lamp, White (120V) 0820-033 Lamp, Red (240V), Shatterproof 0820-014-SP Socket 0822-037 Switch 0808-002 Reel/Pulley Assembly 1287-084 Coil Cord (IFW63) 0834-006 Coil Cord (IFW63L) 0834-007
FL-2093
5. Lower or raise the coil cord to the height you want.
6. Adjust the tension of the coil cord in the slot as shown.
a. To increase tension, turn slot
clockwise.
b. To decrease tension, turn slot
counter clockwise.
7. Pull up canopy (2) and screw it to the plate (4) with two machine screws (3).
8. Screw lamp into socket.
DO NOT PULL DOWN ON THE CORD BEYOND THE STOP.