Cres Cor HJ-531-13-180 Installation Manual

Page 1
Heated Dish
Dolly
FL-0508
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: HJ-531-10-240 and HJ-531-13-180
JETSTREAM HEATED DISH DOLLY
ELECTRICAL SPECIFICATIONS:
MODEL NO. Volts Watts Amps Hertz Phase Service
HJ-531-10-240 HJ-531-13-180
HJ-531-10-240-240 HJ-531-13-180-240
HOW TO INSTALL UNIT:
1. Plug cord into receptacle in back of unit.
2. Turn clockwise to lock.
3. Plug other end into 15 Amp wall outlet.
120 1000 8.4 60 1 AC
240 1000 4.2 60 1 AC
MAINTENANCE:
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
HOW TO START UNIT:
1. Flip switch ON. Yellow light will come on.
2. Turn thermostat to #7 (150° F to 160° F / 66° C to 71° C) which will warm the plates.
3. Hint: Dial has a range of #1 to #10 (60° F to 250° F / 16° C to 121° C).
4. Pre-heat dolly for 30 minutes.
5. Add plates.
HOW TO TURN UNIT OFF:
Flip switch OFF.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
REPLACEMENT PARTS
Description 120 Volt 240 Volt
Blower Kit 0769-180-K 0769-182-K Cord Set 0810-031-1 0810-032-01 Heater Assembly 0811-074 0811-074-01 Receptacle 0713-011 0713-012 Red Light 0766-047 0766-046 Switch 0808-011 0808-020 Thermostat Kit 0848-062-K 0848-062-K Yellow Light 0766-048 0766-045
Right Hand Left Hand
Door, HJ-531-10-240 Door, HJ-531-13-180 Door Latch, complete Hinge
5686-011-K 5686-012-K 1246-015-K 1246-015-K 0519-018-K
5686-013-K 5686-014-K
0519-019-K
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 2
Heated Dish
Dolly
FL-0508
Rev. 22 (10/13) Page 2 of 2
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: HJ-531-10-240 and HJ-531-13-180
JETSTREAM HEATED DISH DOLLY
TROUBLE-SHOOTING:
Failure Cause
1a. Cord not plugged into dolly or wall outlet.
1. Yellow light not on.
2. Unit does not get hot. 2a. Thermostat set too low.
3. Unit gets too hot or won’t shut off. 3a. Defective electrical parts; unplug cord from wall outlet.
If the cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
WARNING
BEFORE CLEANING CABINET:
1. Remove Power Cord from cabinet.
2. Do NOT hose cabinet with water.
3. Do NOT get water on controls.
4. Do NOT use abrasives or harsh chemicals.
1b. Circuit breaker/fuse to wall outlet blown. 1c. Switch is off.
Cleaning Hints:
1. Wipe up spills as soon as possible.
2. Clean regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners.
6. Avoid drips and splashes.
Dolly
Inside and Outside
(Aluminum)
LEGEND
SW SWITCH (SPST) BM BLOWER MOTOR TH THERMOSTAT H HEATER A AMBER PILOT LIGHT R RED PILOT LIGHT L5-15R RECEPTACLE, 110V/15A L6-15R RECEPTACLE, 220V/15A
ELECTRICAL SPEC
120/240V 1000W 1 PHASE 60 HZ AC SERVICE
SOIL CLEANER METHOD
Mild detergent* and hot water, or mild
DIRT
FINGERPRINTS, GREASE OIL
WATER SPOTS Mild abrasive cleaner. Wipe with damp cloth.
* Mild detergents include soaps and non-abrasive cleaners
abrasive cleaner.
Steam (no strong alkaline additive)
Detergent* and hot water.
Mild abrasive cleaner. Oily or waxy cleaner.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry.
1. Wipe with soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
Apply with soft, clean cloth.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com