Cres Cor HC1-UA-11 Installation Manual

Holding Cabinet
WARNING
FL-2387
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: HC1-UA-11 Hot Cabinet
Rev. 1 (07/15) Page 1 of 8
Cabinet model number:
Cabinet serial number:
Authorized Service Agency:
Keep this manual for future reference.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
HC1-UA-11
IMPROPER INSTALLATION, SERVICE, ADJUSTMENTS, ALTERATIONS CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
Holding Cabinet
FL-2387
Rev. 1 (07/15) Page 2 of 8
5925 Heisley Road • Mentor, OH 44060-1833
TABLE OF CONTENTS
SUBJECT PAGE
INSTALLATION INSTRUCTIONS .............................................3
OPERATING INSTRUCTIONS ................................................6
Illustration, Figure 1 ..........................................................6
MAINTENANCE INSTRUCTIONS
How to Clean the Unit ...................................................7
Trouble Shooting Guide and Wiring Diagram .................................8
Illustration; Cabinet assembly replacement parts ...............................9
SERVICE POLICY and AGENCY LIST ....................................FL-1400
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Holding Cabinet
FL-2387
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 1 (07/15) Page 3 of 8
INSTALLATION INSTRUCTIONS
INSTRUCTIONS TO INSTALLER BEFORE CONNECTING TO GAS SUPPLIES
1. Retain this manual for further use.
2. Post in a prominent place the following instructions:
FOR YOUR SAFETY
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. Extinguish any open ame.
2. Immediately remove propane tank, shut off gas supply or call your gas supplier.
Do not store or use gasoline
or other ammable vapors
and liquids in the vicinity of
this or any other appliance.
3. Installation in the United States must conform with the local codes, or in the absence of local codes, with the NFPA 54/ANSI Z223.1 2012. Installation in Canada must comply with the Installation codes for Gas Burning Appliances and Equipment, CAN/CSA B149.1-10 and/or local codes.
4. The area around cabinet must be kept free and clear from combustible materials.
5. DO NOT obstruct the ow of combustion and ventilation air. DO NOT block slots or louvers on front and rear of unit in any way.
6. Provisions for adequate air supply, in cabinet area, must be provided.
7. Adequate clearances for servicing and proper operation must be provided.
8. CLEARANCE FROM COMBUSTIBLE CONSTRUCTION, 0 INCHES FROM SIDE AND 0 INCHES FROM BACK.