IMPROPER INSTALLATION, SERVICE,
ADJUSTMENTS, ALTERATIONS CAN
CAUSE PROPERTY DAMAGE, INJURY
OR DEATH. READ THE INSTALLATION
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
INSTRUCTIONS TO INSTALLER BEFORE CONNECTING TO GAS SUPPLIES
1. Retain this manual for further use.
2. Post in a prominent place the following instructions:
FOR YOUR SAFETY
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. Extinguish any open ame.
2. Immediately remove propane tank,
shut off gas supply or call your gas
supplier.
Do not store or use gasoline
or other ammable vapors
and liquids in the vicinity of
this or any other appliance.
3. Installation in the United States must conform with the local codes, or in the absence of local codes, with
the NFPA 54/ANSI Z223.1 2012. Installation in Canada must comply with the Installation codes for Gas
Burning Appliances and Equipment, CAN/CSA B149.1-10 and/or local codes.
4. The area around cabinet must be kept free and clear from combustible materials.
5. DO NOT obstruct the ow of combustion and ventilation air. DO NOT block slots or louvers on front and
rear of unit in any way.
6. Provisions for adequate air supply, in cabinet area, must be provided.
7. Adequate clearances for servicing and proper operation must be provided.
8. CLEARANCE FROM COMBUSTIBLE CONSTRUCTION, 0 INCHES FROM SIDE AND 0 INCHES
FROM BACK.
for use with natural gas. It is not userconvertible to natural gas.
1. Only use a 1 lb. standard cylinder marked
“PROPANE”. A larger tank can be used with an
adapter (optional accessory part number 0904-026-K
See installation FL-2362).
2. The cylinder must be constructed and marked in
accordance with the specications for propane
cylinders of the U.S. Department of Transportation
(DOT) or CAN/CSA B339.
3. The Cylinder should not be allowed to remain in a
high heat area, such as a car, truck or direct sunlight.
DO NOT store at temperatures above 120°F (49° C)
and in unauthorized storage areas not intended for
cylinder storage.
5925 Heisley Road • Mentor, OH 44060-1833
GENERAL INSTALLATION:
1. Remove all paper and packing materials from the
inside of the cabinet and install angles into posts.
2. Remove protective paper and vinyl material from
the outside of the cabinet.
3. Place the cabinet in a well-ventilated area on level
oor or ground.
4. DO NOT block the ue vent located at the upper
rear of the cabinet.
5. Lock the two front casters before starting up or
plugging in the cabinet.
HOW TO INSTALL ANGLES:
1. Insert end tabs of the angles into the post slots
and push down.
2. Note the location shown in the diagram of the
18” x 26” pan slide and the 12” x 20” pan slide
18” X 26” BUN PAN
4. Hold and use the cylinder in an upright position and
only use when temperatures are above 10°F (-12° C).
Do not attach near ames, pilot lights or sparks.
5. Propane Tank Hook-up:
a. Make sure the gas valve is in the “OFF” position.
b. Uncap the cylinder, hold upright and insert it in the
right rear compartment of the cabinet. Hand screw
and tighten the cylinder to the gas regulator. DO
NOT over-tighten.
Check for leaks at the connection: Spray soapy water
onto the connection and look for bubbles. Tighten more if
needed.
6. Disconnect the cylinder when not in use. Replace the
cylinder cap when storing.