Cres Cor HC1-UA-11 Installation Manual

Page 1
Holding Cabinet
WARNING
FL-2387
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: HC1-UA-11 Hot Cabinet
Rev. 1 (07/15) Page 1 of 8
Cabinet model number:
Cabinet serial number:
Authorized Service Agency:
Keep this manual for future reference.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
HC1-UA-11
IMPROPER INSTALLATION, SERVICE, ADJUSTMENTS, ALTERATIONS CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
Page 2
Holding Cabinet
FL-2387
Rev. 1 (07/15) Page 2 of 8
5925 Heisley Road • Mentor, OH 44060-1833
TABLE OF CONTENTS
SUBJECT PAGE
INSTALLATION INSTRUCTIONS .............................................3
OPERATING INSTRUCTIONS ................................................6
Illustration, Figure 1 ..........................................................6
MAINTENANCE INSTRUCTIONS
How to Clean the Unit ...................................................7
Trouble Shooting Guide and Wiring Diagram .................................8
Illustration; Cabinet assembly replacement parts ...............................9
SERVICE POLICY and AGENCY LIST ....................................FL-1400
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 3
Holding Cabinet
FL-2387
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 1 (07/15) Page 3 of 8
INSTALLATION INSTRUCTIONS
INSTRUCTIONS TO INSTALLER BEFORE CONNECTING TO GAS SUPPLIES
1. Retain this manual for further use.
2. Post in a prominent place the following instructions:
FOR YOUR SAFETY
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. Extinguish any open ame.
2. Immediately remove propane tank, shut off gas supply or call your gas supplier.
Do not store or use gasoline
or other ammable vapors
and liquids in the vicinity of
this or any other appliance.
3. Installation in the United States must conform with the local codes, or in the absence of local codes, with the NFPA 54/ANSI Z223.1 2012. Installation in Canada must comply with the Installation codes for Gas Burning Appliances and Equipment, CAN/CSA B149.1-10 and/or local codes.
4. The area around cabinet must be kept free and clear from combustible materials.
5. DO NOT obstruct the ow of combustion and ventilation air. DO NOT block slots or louvers on front and rear of unit in any way.
6. Provisions for adequate air supply, in cabinet area, must be provided.
7. Adequate clearances for servicing and proper operation must be provided.
8. CLEARANCE FROM COMBUSTIBLE CONSTRUCTION, 0 INCHES FROM SIDE AND 0 INCHES FROM BACK.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 4
Holding Cabinet
WARNING
FL-2387
Rev. 1 (07/15) Page 4 of 8
INSTALLATION INSTRUCTIONS
HC1-UA-11 FOR PROPANE CYLINDER INSTALLATION:
This cabinet is
not intended
for use with natural gas. It is not user­convertible to natural gas.
1. Only use a 1 lb. standard cylinder marked “PROPANE”. A larger tank can be used with an adapter (optional accessory part number 0904-026-K See installation FL-2362).
2. The cylinder must be constructed and marked in
accordance with the specications for propane
cylinders of the U.S. Department of Transportation (DOT) or CAN/CSA B339.
3. The Cylinder should not be allowed to remain in a high heat area, such as a car, truck or direct sunlight.
DO NOT store at temperatures above 120°F (49° C)
and in unauthorized storage areas not intended for cylinder storage.
5925 Heisley Road • Mentor, OH 44060-1833
GENERAL INSTALLATION:
1. Remove all paper and packing materials from the inside of the cabinet and install angles into posts.
2. Remove protective paper and vinyl material from the outside of the cabinet.
3. Place the cabinet in a well-ventilated area on level
oor or ground.
4. DO NOT block the ue vent located at the upper rear of the cabinet.
5. Lock the two front casters before starting up or plugging in the cabinet.
HOW TO INSTALL ANGLES:
1. Insert end tabs of the angles into the post slots and push down.
2. Note the location shown in the diagram of the 18” x 26” pan slide and the 12” x 20” pan slide
18” X 26” BUN PAN
4. Hold and use the cylinder in an upright position and
only use when temperatures are above 10°F (-12° C). Do not attach near ames, pilot lights or sparks.
5. Propane Tank Hook-up:
a. Make sure the gas valve is in the “OFF” position.
b. Uncap the cylinder, hold upright and insert it in the right rear compartment of the cabinet. Hand screw and tighten the cylinder to the gas regulator. DO
NOT over-tighten.
Check for leaks at the connection: Spray soapy water onto the connection and look for bubbles. Tighten more if needed.
6. Disconnect the cylinder when not in use. Replace the cylinder cap when storing.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
12” X 20” STEAM TABLE PAN
Page 5
Holding Cabinet
FL-2387
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING INSTRUCTIONS
HOW TO HOLD FOOD:
Air is VERY HOT
WARNING
PROCEDURE FOR LIGHTING:
NOTE: DO NOT PUT FOOD INTO CABINET! This step is to burn off manufacturing oils and excess
adhesive. Let the cabinet cool and wipe inside clean with detergent and hot water before rst use.
Dials must be operated by hand. DO NOT use pliers, wrenches or other tools to turn dials.
The Gas Valve Dial cannot be turned to “OFF” position without rst depressing dial in “PILOT” position and then
rotating to “OFF”.
when door is opened.
Rev. 1 (07/15) Page 5 of 8
NOTE: When unit is not in use, ALWAY S store unit with
the Gas Valve Dial in the “OFF” position. Remove
the propane source for added safety and turn the thermostat to the “OFF” position.
1. Turn thermostat knob to “HIGH”.
2. Turn Gas Valve Dial to the “PILOT” position.
3. DEPRESS and HOLD Gas Valve Dial, allow pilot to burn approximately 30 seconds before RELEASING
Gas Valve Dial. If pilot does not remain lighted, repeat
operation allowing longer period before releasing Gas
Valve Dial.
4. The appliance is now in operation. When heat is
desired, turn Gas Valve Dial to “ON” position. When heat is no longer required, turn Gas Valve Dial back to
“PILOT” position.
5. When the unit is in the “ON” position adjust the ther­mostat accordingly (“High”, “Medium”, “Low”).
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 6
Holding Cabinet
WARNING
FL-2387
Rev. 1 (07/15) Page 6 of 8
MAINTENANCE INSTRUCTIONS
BEFORE cleaning the cabinet, allow cabinet to cool.
CAUTION
1. Do NOT use abrasives (steel wool) or harsh chemicals (chlorine, bromine, iodine or ammonia).
2. Do NOT use a water sprayer (pressure sprayer) to clean the cabinet.
3. Do not use Cres Clean on label or plastic materials.
5925 Heisley Road • Mentor, OH 44060-1833
Cleaning hints:
1. Wipe up spills as soon as possible.
2. Clean cabinet daily to avoid heavy dirt build-up.
3. Make a test spot with cleaner: a) Follow manufacturer’s directions on cleaner. b) Do not mix cleaners.
c) Avoid drips and splashes.
HOW TO CLEAN THE UNIT:
Soil Cleaner Method
OUTER CABINET
(Powder Coat)
CABINET
Inside and
Door
(Stainless Steel)
WEEKLY, OR AS NEEDED
DAILY CLEANING
STUBBORN SPOTS AND STAINS
BURNT-ON FOODS OR GREASE
HARD WATER SPOTS and SCALE
*Mild detergents include soaps and non-abrasive cleaners.
Mild detergent and warm water.
Mild detergent and hot water.
Mild abrasive made for stainless steel.
Chemical oven cleaner for stainless steel.
Vinegar
1. Wipe with clean, soft cloth.
2. Rinse well.
3. Dry gently.
1. Sponge on with cloth.
2. Rinse with water.
3. Wipe dry.
1. Apply with damp sponge or cloth.
2. Rub lightly.
3. Rinse with water and wipe dry.
Follow oven cleaner manufacturer’s directions.
1. Swab or wipe with cloth.
2. Rinse and dry.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 7
Holding Cabinet
FL-2387
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 1 (07/15) Page 7 of 8
TROUBLE-SHOOTING
FAILURE POSSIBLE CAUSE
1. Unit does not turn on. 1a. Battery is low on charge. 1b. Gas tank is empty.
2. Unit heats up slowly. 2a. Check operating instructions for preheat times.
2b. Defective components.
3. Unit does not heat. 3a. Unit is not on. 3b. Thermostat is set too low. 3c. Propane/gas tank has expired.
3d. A gust of wind may have blown out the ame or
prevented ignition of the gas.
4. Unit gets too hot or won’t shut off. 4. Defective thermostat.
For repairs, refer to our list of Authorized Service Centers, FL-1400
NOTE: If any panel which is sealed with silicone needs to be removed for servicing by an authorized personnel,
the exterior seams need to be sealed with a food grade caulking material (certied against NSF/ANSI 51).
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 8
Holding Cabinet
FL-2387
Rev. 1 (07/15) Page 8 of 8
Include all information on nameplate when ordering parts
3
5925 Heisley Road • Mentor, OH 44060-1833
REPLACEMENT PARTS
2
3
1
4
PROPANE TANK HOOK-UP AREA
12 13
16
9
11
10
8
5
6
ITEM DESCRIPTION 120V
1 Door Assembly 1221-649 2 Hinge (2 per kit) 0519-110-K 3 Latch 1006-143-K 4 Gasket, Door 0861-182-K 5 Casters, Rigid 0569-341-R 6 Casters, w/Brake 0569-341-B 7 Wire Angles (2 per kit) 0621-352-K 8 Sight Glass 0574-167
9 Regulator 8100-009 10 Battery 9V 7037-010 11 Igniter 8100-027 12 Thermostat 0848-062 13 Knob 0595-001 14 Burner 8100-002-01 15 Pilot Ass’y 8100-029 16 Gas Valve 8100-025
15
14
UNDERNEATH CABINET SHOWN WITH
BASE & COVERS REMOVED
8100-025-A KNOB
ITEM #16, GAS VALVE
MICRO-SWITCH 0808-127
ASSEMBLY
8100-025
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Loading...