Cres Cor H135SUA11 Service Manual

Page 1
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
H135UA11 Hot Cabinet (Aluminum)
H135SUA11 Hot Cabinet (Stainless Steel)
Hot Cabinets Rev. 2 (2/07) Page 1 of 4
FL-2328
H135UA11 H135SUA11
H135UA11240 H135SUA11240
All are designed for AC service. The above model numbers may be followed by “M”, “L”, “D”, “R” and ending with “S” or “Z”.
CONTROL PANEL PARTS IDENTIFICATION
1. Power Switch
2. Yellow Light-Power
120 1470 12.3 60 1 5-15P
240 1470 6.1 60 1 6-15P
3. Thermostat
4. Thermometer
HOW TO INSTALL UNIT:
Place cabinet near warm ovens. Do NOT put in
1. drafty areas or near ventilating systems. Plug cord end into proper wall outlet.
2.
HOW TO START UNIT:
Turn the POWER switch on. The yellow light will
1. turn on. Turn thermostat to #10.
2. Preheat cabinet for 30 minutes.
3. Put food into cabinet.
4. Turn thermostat to #8 and close door.
5.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
NOTE: No. 8 setting = approx. 190°F (88°C)
No. 6 setting = approx. 165°F (74°C)
Proper food holding temperature is 140°F (60°C) or higher. The thermometer shows the temperature inside.
TO TURN OFF UNIT:
Turn thermostat off.
1. Turn the POWER switch off.
2. The yellow light will go out.
3.
Page 2
Hot Cabinets Rev. 2 (2/07) Page 2 of 4
FL-2328
OPERATING and MAINTENANCE INSTRUCTIONS
H135UA11 Hot Cabinet (Aluminum)
H135SUA11 Hot Cabinet (Stainless Steel)
MAINTENANCE
HOT UNIT REMOVAL INSTRUCTIONS:
Unplug power cord from wall outlet.
1. Pull entire unit out the front of the cabinet.
2.
HOW TO CLEAN THE CABINET:
5925 Heisley Road • Mentor, OH 44060-1833
Allow cabinet to cool.
1. Remove Hot unit from cabinet.
2. Do NOT use abrasives or harsh
3. chemicals.
HOW TO CLEAN UNIT:
Soil Cleaner Method
DOORS
Vinyl (Out)
Aluminum (In)
CABINETS
(H137UA11 is
Aluminum)
(H137SUA11 is
Stainless Steel)
Dirt, Grease and Oil
Dirt
Fingerprints, Grease
and Oil
Water Spots
BEFORE cleaning the cabinet:
Mild Detergent* and water.
Mild detergent* and hot water, or mild abrasive cleaner.
Steam (No strong alkaline additive)
Chemical oven cleaner for cabinet material
Mild abrasive cleaner; oily or waxy cleaner
Mild abrasive cleaner. Oily of waxy cleaner.
Cleaning Notes:
Wipe up spills as soon as possible.
1. Clean cabinet regularly to avoid heavy dirt build-up.
2. Make a test spot with cleaner.
3. Follow manufacturer’s directions on cleaner.
4. Do not mix cleaners.
5. Avoid drips and splashes.
6.
1. Wipe with soft, damp cloth.
2. Rinse well.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry. Follow oven manufacturer’s directions Apply with clean, soft cloth. Wipe with
damp cloth. Apply with soft, clean cloth.
Wipe with damp cloth.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 3
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
H135UA11 Hot Cabinet (Aluminum)
H135SUA11 Hot Cabinet (Stainless Steel)
TROUBLE-SHOOTING CHART:
FAILURE POSSIBLE CAUSE
1. Yellow light at switch does NOT light.
1a. Circuit breaker/fuse to wall outlet is blown. 1b. Cord is unplugged from wall outlet. 1c. Switch is “OFF”.
Hot Cabinets Rev. 2 (2/07) Page 3 of 4
FL-2328
2. Unit does not heat.
3. Unit gets too hot or won’t shut off. 3a. Defective electrical parts. UNPLUG UNIT FROM
4. Blower does not work or makes noise. 4a. Defective blower. NOTE: Optional digital thermometer will fl ash if cabinet temperature is below 140° F or above 250° F.
Call the factory if you need different settings. If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
REPLACEMENT PARTS:
DESCRIPTION 120 VOLT 240 VOLT
Hot Unit (H35UA11) HU-1254-058 HU-1254-059 Hot Unit (H135SUA11) HU-1254-062 HU-1254-063 Blower Kit 0769-180 0769-182-K Heater Kit 0811-019 0811-020 Thermostat Kit 0848-062-K 0848-062-K Thermometer Kit (Analog) 5238-030-K 5238-030-K Power Cord 0810-029 0810-039 Power Switch 0808-116 0808-116 Power Light 0766-094 0766-095 Terminal Block 0852-091 0852-091
2a. Thermostat set too low or is “OFF”. 2b. Switch is “OFF”.
WALL OUTLET.
CABINET
Door Latch 1006-154-01 Door Hinge 0519-104 Pan Slides 0621-181 Door Assembly , Silver 1200-495-BL Door Assembly , Red 1200-499-BL Door Gasket 0861-259
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 4
Hot Cabinets Rev. 2 (2/07) Page 4 of 4
FL-2328
OPERATING and MAINTENANCE INSTRUCTIONS
H135SUA11 Hot Cabinet (Stainless Steel)
WIRING DIAGRAM:
5925 Heisley Road • Mentor, OH 44060-1833
H135UA11 Hot Cabinet (Aluminum)
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Loading...