Cres Cor EB-64, EB-96, EB-120, EB-150-XX Service Manual

Page 1
Insulated
Banquet Cabinet
FL-2370
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB Banquet Warming Cabinets
Model No. Volts Watts Amps Hertz Phase NEMA
EB-64 EB-96 EB-120 EB-150 EB-150-XX
HOW TO INSTALL UNIT:
1. Remove all packing material from inside the cabinet and clean cabinet thoroughly.
2. Install all channels and shelves before the unit is put into operation.
3. Plug the power cord into the proper wall outlet.
120 1500 12.5 60 1 5-15P
208 1500 7.3 60 1 6-15P
240 1500 6.3 60 1 6-15-P
Models are designed for AC Service.
Rev. 0 (1/13) Page 1 of 4
TO TURN OFF UNIT:
Push the POWER switch to “OFF”.
The yellow light will go out.
HOW TO START UNIT:
1. Turn the POWER switch “ON”. The yellow light will turn on.
2. Turn the thermostat to no. 10.
3. Preheat (assuming a “cold” cabinet of 75°F/25°C):
To 150°F/65°C takes about 30 mins. To 175°F/79°C takes about 45 mins. To 190°F/88°C takes about 1 hour.
4. Put food into the cabinet.
5. Turn the thermostat to the required temperature.
NOTE: No. 8 is about 180°F/82°C
No. 7 is about 160°F/71°C No. 6 is about 145°F/63°C
Proper food holding temperature is 140°F / 60°C or
higher.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Thermometer
Switch w/Light
Thermostat
Page 2
Insulated
Banquet Cabinet
FL-2370
Rev. 0 (1/13) Page 2 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB Banquet Warming Cabinets
WARNING
MAINTENANCE: Hot Unit Removal Instructions
1. Unplug power cord from wall outlet and remove cord from clip.
2. Lift up the bottom shelf: then lift up the hot unit about 5 inches and pull out.
HOW TO CLEAN THE UNIT:
5925 Heisley Road • Mentor, OH 44060-1833
Cleaning hints:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners.
6. Avoid drips and splashes.
BEFORE Cleaning the Cabinet:
1. Allow cabinet to cool.
2. Remove hot unit from cabinet.
3. Do NOT use abrasives or harsh chemicals.
4. High pressure cleaning is recommended for cabinet exterior.
Soil Cleaner Method
Routine Cleaning Soap, ammonia, or
detergent* and water
CABINETS
(Stainless Steel)
Stubborn spots and stains
Burnt-on foods or grease.
Hard water spots and scale.
Mild abrasive made for stainless steel
Chemical oven cleaner 1. Apply generous coating.
Vinegar 1. Swab or wipe with cloth.
*Mild detergents include soaps and non-abrasive cleaners.
1. Sponge on with cloth.
2. Rinse.
1. Apply with damp cloth.
2. Rub lightly.
2. Allow to stand for 10-15 minutes.
3. Rinse.
4. Repeat application if necessary.
2. Rinse dry.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 3
Insulated
Banquet Cabinet
FL-2370
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 0 (1/13) Page 3 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB Banquet Warming Cabinets
TROUBLE-SHOOTING CHART:
FAILURE: POSSIBLE CAUSE:
1. Yellow light at switch does NOT light.
2. Unit does not heat.
3. Unit gets too hot or won’t shut off. 3a. Defective electrical parts.
4. Blower does not work or makes noise. 4a. Defective blower
5. Excess moisture in cabinet. 5. “Slack out” foods from oven or fryer for 5 minutes before
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400
1a. Circuit breaker/fuse to wall outlet is blown 1b. Cord is unplugged from wall outlet. 1c. Switch is “OFF.”
2a. Thermostat set too low or is “OFF.” 2b. Switch is “OFF.”
UNPLUG UNIT FROM WALL OUTLET
putting in hot cabinet.
REPLACEMENT PARTS:
DESCRIPTION 120 VOLT 208 VOLT 240 VOLT
Power Unit 1254-065 1254-066 1254-067 Blower Kit 0769-180-K 0769-182-K 0769-182-K Heater Kit 0811-244 0811-245 0811-246 Thermostat Kit 0848-062-K 0848-062-K 0848-062-K Thermometer Kit 5238-030-K 5238-030-K 5238-030-K Power Cord 0810-029-02 0810-039-03 0810-039-03 Power Switch 0808-113-K 0808-113-01-K 0808-113-01-K Terminal Block 0852-091 0852-091 0852-091
CABINET MODEL NOS:
EB-64 EB-96 EB-120 EB-150/EB-150XX
Door Latch 1006-143-K 1006-143-K 1006-143-K 1006-143-K Door Strike 1006-151-K 1006-151-K 1006-151-K 1006-151-K Door Hinge 0519-084 0519-084 0519-084 0519-084 Door Gasket Kit 0861-285-K 0861-285-K 0861-281-K 0861-282-K Door Assembly, Complete 1221-615 1221-615 1221-607 1221-611 Wire Grid 1170-232 1170-232 1170-205 1137-231 Pull Handle 0911-119 0911-119 0911-119 0911-119
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Page 4
Insulated
BLOWER
Banquet Cabinet
FL-2370
Rev. 0 (1/13) Page 4 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB Banquet Warming Cabinets
THERMOSTAT
AIR
4
3
5925 Heisley Road • Mentor, OH 44060-1833
6-15P PLUG
208V, 15A
240V, 15A
W
5-15P PLUG
120V, 15A
GG
(LIGHTED)
2
SWITCH
POWER
1
4
1
2
5
3
5
HEATER
AIR
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com