Cres Cor EB-150-CAN, EB-150-208, EB-150-240 Operators Manual

Insulated
Banquet Cabinet
FL-2257
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB-150 Banquet Warming Cabinet
Model No. Volts Watts Amps Hertz Phase NEMA
EB-150 120 1500 12.5 60 1 5-15P *EB-150-CAN 120 1500 12.5 60 1 5-20P EB-150-208 208 1500 7.3 60 1 6-15P EB-150-240 240 1500 6.3 60 1 6-15P
Models are designed for AC Service.
*For Canadian use.
HOW TO INSTALL UNIT:
Remove all packing material from inside the
1. cabinet and clean cabinet thoroughly. Install all channels and shelves before the unit is
2. put into operation. Plug the power cord into the proper wall outlet.
3.
Rev. 4 (4/07) Page 1 of 4
TO TURN OFF UNIT:
Push the POWER switch to “OFF”. The yellow light will go out.
HOW TO START UNIT:
Turn the POWER switch “ON”. The yellow light
1. will turn on.
Turn the thermostat to no. 10.
2. Preheat (assuming a “cold” cabinet of 75°F/25°C):
3.
To 150°F/65°C takes about 30 mins. To 175°F/79°C takes about 45 mins. To 190°F/88°C takes about 1 hour.
4. Put food into the cabinet.
5. Turn the thermostat to the required temperature.
NOTE: No. 8 is about 180°F/82°C
No. 6 is about 155°F/69°C
Proper food holding temperature is 140°F / 60°C or
higher.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Thermometer
Switch w/Light
Thermostat
Insulated
Banquet Cabinet
FL-2257
Rev. 4 (4/07) Page 2 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB-150 Banquet Warming Cabinet
MAINTENANCE: Hot Unit Removal Instructions
Unplug power cord from wall outlet.
1. Lift unit off from the front and rear of cabinet.
2.
HOW TO CLEAN THE UNIT:
5925 Heisley Road • Mentor, OH 44060-1833
Cleaning hints:
Wipe up spills as soon as possible.
1. Clean cabinet regularly to avoid heavy dirt build-up.
2. Make a test spot with cleaner.
3. Follow manufacturer’s directions on cleaner.
4. Do not mix cleaners.
5. Avoid drips and splashes.
6.
BEFORE Cleaning the Cabinet:
Allow cabinet to cool.
1. Remove hot unit from cabinet.
2. Do NOT use abrasives or harsh chemicals.
3. High pressure cleaning is recommended for
4. cabinet exterior.
HOW TO CLEAN UNIT:
SOIL CLEANER METHOD
Routine cleaning Soap, ammonia, or
detergent* and water
CABINET
(Stainless Steel)
Stubborn spots and stains
Burnt-on foods or grease
*Mild detergent include soaps and non-abrasive cleaners
Mild abrasive made for stainless steel
Chemical oven cleaner Follow oven cleaner
1. Sponge on with cloth
2. Rinse
1. Apply with damp sponge or cloth
2. Rub lightly
manufacturer’s directions
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Banquet Cabinet
FL-2257
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB-150 Banquet Warming Cabinet
TROUBLE-SHOOTING CHART:
FAILURE: POSSIBLE CAUSE:
1. Yellow light at switch does NOT light.
2. Unit does not heat.
3. Unit gets too hot or won’t shut off. 3a. Defective electrical parts.
4. Blower does not work or makes noise. 4a. Defective blower
5. Excess moisture in cabinet. 5a. Open vent
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400
1a. Circuit breaker/fuse to wall outlet is blown 1b. Cord is unplugged from wall outlet. 1c. Switch is “OFF.”
2a. Thermostat set too low or is “OFF.” 2b. Switch is “OFF.”
UNPLUG UNIT FROM WALL OUTLET
5b. “Slack out” foods from oven or fryer for 5 minutes
before putting in hot cabinet.
Rev. 4 (4/07) Page 3 of 4
REPLACEMENT PARTS:
DESCRIPTION 120 VOLT 208 VOLT 240 VOLT
Power Unit 1254-047 1254-048 1254-049 Blower Kit 0769-005-K 0769-006-K1 0769-006-K1 Heater Kit 0811-244 0811-245 0811-246 Thermostat Kit 0848-062-K 0848-062-K 0848-062-K Thermometer Kit 5238-030-K 5238-030-K 5238-030-K Power Cord 0810-029-02 0810-039-03 0810-039-03 Power Switch 0808-113-K 0808-113-01-K 0808-113-01-K
CABINET PARTS:
Door Latch 1006-143-K Door Strike 1006-151-K Door Hinge 0519-084 Door Gasket Kit 0861-243 Door Assembly Complete 1221-529 Wire Grid 1170-205 Push Handle 1072-117-K
EB-150-CAN: (120V for Canada)
Power Unit 1254-050 Power Cord 0810-029-03
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
R
Banquet Cabinet
FL-2257
Rev. 4 (4/07) Page 4 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: EB-150 Banquet Warming Cabinet
THERMOSTAT
AIR
4
3
5925 Heisley Road • Mentor, OH 44060-1833
6-15P PLUG
208V, 15A
240V, 15A
W
5-15P PLUG
120V, 15A
GG
G
W
(LIGHTED)
2
SWITCH
POWER
1
120V 20A
5-20P
4
1
2 5
3
HEATER
AIR
5
BLOWE
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com