Cres Cor CCBC-12-75, CCBC12-UA-100, CCBC-4-35 User Manual

BLAST CHILLERS
MODEL NUMBERS
FL 2242
Feb. 2000
CCBC-4-35
CCBC12-UA-100
INSTALLATION, OPERATION & SERVICE
MANUAL
TABLE OF CONTENTS
BLAST CHILLER INTRODUCTION Page 1
SECTION 1 DESCRIPTION Page 2 Chill Processing CCBC-4-35 Features and Specifications Page 3 CCBC-12-75 Features and Specifications Page 5 CCBC-12-UA-100 Features and Specifications Page 7 Control Panel Layout Page 9 SECTION 2 INSTALLATION Page 10 Unpacking and Installation Instructions
SECTION 3 OPERATION Page 13 Start-Up Information "
How to Operate " Blast Chill Cycle/Modes Page 14 Loading of Product Page 15 Defrosting Blast Chill " Printer Page 17
SECTION 4 MAINTENANCE Page 18 How to clean the Blast Chiller
SECTION 5 TROUBLESHOOTING Page 19 SECTION 6 Page 24 Expanded Drawings of Units & Parts List
Rules of Thumb And Guidelines Page 31
Contact & Warranty Registration Information Page 32
Preparation Guidelines Page 34
INTRODUCTION [ Page 1 ]
BLAST CHILLER INTRODUCTION
THE BLAST CHILLER is the easiest and simplest way to chill foods safely without additional labor. All food service operators prepare foods in advance or chill foods at the end of a workday. More often than not the foods are chilled in standard refrigeration, often creating an unsafe time and temperature environment. In using a BLAST CHILLER food products are produced in the same manner and with the same equipment which is used for conventional food preparation and chilled in a BLAST CHILLER. The BLAST CHILLER resembles a reach in refrigerator. The BLAST CHILLER is a unit that moves cool air at a high circulation over the top and bottom of each pan thus ensuring a rapid even chilling time. Almost all foods are chilled within 2 hours out of the danger zone 140°F to 41°F. The time necessary to bring the internal food temperature to 41°F. (5°C) is affected by the food density, moisture content and the food’s ability to retain heat. Blast chilled food has a shelf life of five days, including day of production and service. Blast chilling works well with a wide range of menu items. Nearly any food product that can be portioned into a standard 2-1/2” hotel pan can be successfully blast chilled. These systems are used for services from 50 to 10,000 meals per day.
STEPS IN THE BLAST CHILL PROCESS
1. Prepare all food products to the point of consumption. Within 30 minutes, portion into 2-1/2 inch deep
half-full pan or sheet pan at a depth of no more than 2 inches and weight of no more than 8 lbs.
2. Place pans of cooked product in the BLAST CHILLER and strategically place probe in the center of
the pan where the internal temperature is brought down to approximately 41°F (5°C) within 90 minutes.
3. At the completion of the “chill cycle” the pans of food product are removed and covered with either a
film wrap or stainless steel lid and labeled.
4. The product is stored in a refrigerator and maintained at a temperature between 33°F (1°C) and 38°F
(3°C).
5. The food product is rethermed just prior to the required meal service in bulk or individual portion.
[ Section 1-Description ] [ Page 2 ]
Chill Processing Under-Counter and Reach-In Refrigerator/Storage Cabinet
CCBC-4-35
The CCBC-4-35 is ideal for food service operations, which require a small volume blast chiller. This
model is capable of chilling 35 lbs. of food product to 38°F in approximately 90 minutes. Daily capacity
is over 140 lbs. Of processed product.
The comprehensive control panel features built in-alarms and can control the chilling process with the
food core temperature probe or the digital timer.
At the end of the blast chill cycle the cabinet automatically reverts to a 38°F storage refrigerator.
CCBC-12-75 & CCBC-12-UA – 100
The CCBC-12-75 and CCBC-12-UA-100 are ideal for small to medium size food service operations,
which require a blast chilling capability. The CCBC-12-75 is capable of chilling 75 lbs. of food product
to 38°F in approximately 90 minutes. The daily capacity is over 300 lbs. of processed product. The
CCBC-12-UA-100 is capable of chilling 100 lbs. of food product to 38°F in approximately 90 minutes.
Daily capacity is over 400 lbs. of processed product
The comprehensive control panels feature built-in alarms and can control the chilling process with three
food core temperature probes or the digital timer.
At the end of the chill cycle the cabinet automatically reverts to a 38°F storage refrigerator.
[ Section 1-Description ] [ Page 3 ]
CCBC-4-35 Chill Temp Blast Chiller
Standard Features:
Stainless Steel Exterior and Interior
Two Operational Features:
- Blast Chill Processing Refrigerator
- 38°F Storage Refrigerator
Operational Indicator Panel with Microprocessor:
- Blast Chill Cycle Controlled Automatically by Either a Food Probe or Digital Timer
- Four (4) Preset Chilling Times: 30, 60, 90, and 240 minutes
- Cabinet Temperature Digital Display
- Food Temperature Digital Display
- Defrost Mode Indicator
- On/Off, Blast Chill Cycle and Cancel Buttons
Power Failure Alarm
Stainless Steel Top, Front, Sides, Door and Interior
(continued)
[ Section 1-Description ] [ Page 4 ]
A
A
Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic Door
Gaskets
Four (4) Pairs of Adjustable Panslides for 12" x 20" x 2 1/2" Pans
Heavy Duty Casters
Hot Gas Condensate Vaporization
Large Surface Area Evaporator and High Velocity Fan
CFC Free R-134A Refrigerant
SPECIFICATIONS ELECTRICAL DAT
Capacity (lbs/90 mins) 35 lbs. Voltage 208/230V - 60/1 Width 28" Amperage 7 Depth 32" Feed Wires & Ground 2 Open Door Depth 58 3/4" *10 Ft. Cord Installed NEMA 6-15P Height 34.5" *Requires dedicated 15Amp. Service Clear Door Width 21 1/4" Clear Door Height 15" Number Of Tray Slides 4 Sets (2ea) Crated 275 lbs
REFRIGERATION DAT
R134a refrigerant Compressor HP 3/4 HP Width 31" BTU/HR 3,706 Depth 34"
100°F Ambient
Evaporating@+5°F Height 39"
WEIGHT
Uncrated 265 lbs
CRATED DIMENSIONS
[ Section 1-Description ] [ Page 5 ]
CCBC-12-75 Reach-In Blast Chill
Standard Features:
Stainless Steel Exterior and Interior
Two Operational Features:
- Blast Chill Processing Refrigerator
- 38°F Storage Refrigerator
Operational Indicator Panel with Microprocessor:
- Blast Chill Cycle Controlled Automatically by Either Food Probes or Digital
Timer
- Four (4) Preset Chilling Times: 30, 60, 90, or 240 Mins.
- Cabinet Temperature Digital Display
- Defrost Mode Indicator
(continued)
A
A
[ Section 1-Description ] [ Page 6 ]
- Power Failure Alarm
- Three (3) Food Probes with Digital Temperature indicator
Seven (7) Day Temperature Recorder with Printout Demand
Stainless Steel Front, Sides, Door and Interior
Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic Door Gaskets
Twelve (12) Pairs of Adjustable Panslides on 3 1/2" Centers for 18" x 26" Sheet Pans
Six (6) Wire Racks.
Heavy Duty Swivel Casters with Locking Brakes on the Front
Condensate Disposed of Automatically
Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Service
Compartment
Automatic Defrost
CFC Free R-134A Refrigerant
SPECIFICATIONS ELECTRICAL DAT
Capacity 75 lbs. Voltage 208/230V 60/1 Width 35 1/2" Amperage 15 Depth 32" Feed Wires & Ground 2
*
Open Door Depth 58 1/4" Height 77 1/2" Clear Door Width 18 1/4" WEIGHT Clear Door Height 48 1/2" Crated 598 lbs Number Of Tray Slides 12 Sets (2ea) Uncrated 548 lbs Number of Wire Racks 6
REFRIGERATION DAT
Compressor HP 1.5 HP Width 37 1/2" BTU/HR 7,188 Depth 38"
100°F Ambient
Evaporating @ +5°F Height 79"
10 Ft. Cord Installed
*Requires separate 20Amp. Service
CRATED DIMENSIONS
NEMA 6-20P
[ Section 1-Description ] ________[ Page 7 ]
The CBBC-12-UA-100 Reach-In Blast Chiller
Standard Features
Stainless Steel Exterior and Interior
Two Operational Features:
- Blast Chill Processing Refrigerator
- 38°F Storage Refrigerator
Operational Indicator Panel with Microprocessor:
- Full Microprocessor Controlled by a Digital Timer
(continued)
[ Section 1-Description_] ___ ____[ Page 8 ]
- On/Off Switch with Blast Cycle and Cancel Button
- Digital Temperature Display and Defrost Indicator
- Power Failure Alarm
- Food Probe with Digital Temperature Indicator
Galvanized Stee1 Top Stainless Steel Top, Front, Sides, Door and Liner
Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic; Gaskets
Twelve (12) Adjustable Universal Angles
Heavy Duty Swivel Casters with Locking Brakes on the Front
Automatic Defrost
Condensation Disposed of Automatically
Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Compartment
CFC Free R-404A Refrigerant
SPECIFICATIONS ELECTRICAL DATA
Capacity 100 lbs. Voltage 208/230 - 60/3 Width 47" Amperage 15.5 Depth 39 3/8" Feed Wires & Ground 2 Height 84" Number Of Tray Slides 12 Sets (2ea)
WEIGHT
Crated 659 lbs Uncrated 648 lbs
REFRIGERATION DATA
R404A refrigerant Compressor HP 2 HP Width 47" BTU/HR 10,400 Depth 39.375" 100°F Ambient
Evaporating@+5°F Height 84"
CRATED DIMENSIONS
[Page 9]
Control Panel For
CCBC-4-35
1. Select Chill Mode
2. Select Hard or Soft Blast
3. Select Timer for probe or time of process
4. When satisfied with selections, press Check to Start Cycle
5. Press if you want to erase and start
programming over
Cabinet Temperature or "DEF" when in Defrost cycle
Probe Temperature Displayed
Control Panel For
CCBC-12-75 & CCBC-12-UA-100
1. Select Chill Mode
2. Select Hard or Soft Blast
3. Select Timer for probe or time of process
4. When satisfied with selections, press Check to Start Cycle
5. Press if you want to erase and start
programming over
Cabinet Temperature or "DEF" when in Defrost cycle
Probe Temperature Displayed
[ Section 2-Installation ] [ Page 10 ]
UNPACKING INSTRUCTIONS
IMPORTANT:
It is highly recommended that your refrigerator or freezer be installed by an authorized
CresCor Service Agency (List enclosed)
A. Receiving Shipment
Upon arrival, examine the exterior of the shipment packaging for any signs of rough
handling.
If the cabinet is damaged, it should be noted on the delivery slip or bill of lading and signed
to that effect. A claim must be filed immediately against the carrier indicating the extent
and estimated cost of damage incurred.
All units are performance tested and thoroughly inspected prior to shipment. Upon leaving the
factory all units are in perfect condition and the carrier signs to this effect.
B. Uncrating Procedure
WARNING:
DO NOT, Under any Circumstances, Lay Your New Equipment Down on Either The Back,
Front, or Sides!!!
1. Check for any instructions printed on shipping carton.
2. Remove protective cardboard corners, sides and top.
3. Next remove the shipping skid.
4. If any concealed damage is discovered at this time, notify the carrier retain all carton and packing materials until an inspection has been made or waived by the carrier. Taking a photo of the damage is recommended.
CAUTION:
Exercise extreme caution when removing the wooden skid.
5. Please Note the Model and Serial Number located on the inside right hand wall of the unit.
Please take the time to write these numbers down and keep in a safe place. A space has been supplied for this purpose on the last page of this manual. This will assure you quality service and support in the future. Also take the time to register your equipment to activate the warranty.
in writing, and
[ Section 2-Installation ] [ Page 11 ]
C. Removing Plastic Film
Stainless steel surfaces are protected with plastic film when shipped. The film is easily removed by grasping an edge corner of the film and pulling it off.
D. Locating Your new Blast Chill Unit
The cabinet should not be placed in the immediate vicinity of ranges, ovens and other heat radiating equipment. This will help to increase efficiency as well as lower operating costs. Self­contained refrigeration is standard on reach-in chillers. Adequate air ventilation is mandatory for the condensing unit in order to operate efficiently and to prevent excessive and damaging operating temperatures. The Blast Chiller should be in an ambient room temperature of 85° or less.
E. Leveling
The cabinet must be standing level on all four casters for the self-closing doors to operate properly and for proper drainage of condensation from the evaporator. Casters are non­adjustable, therefore the floor must be level.
F. Cleaning (refer to section 4)
G. Electrical Supply
All models (except the CCBC12-UA-100) are furnished with an electrical power cord & NEMA plug, merely requiring that the appropriate NEMA receptacle is available at the installation location. Model CCBC12-UA-100 requires a qualified electrician to furnish and install wiring for the power supply. This must be connected to the identified terminals provided inside the control panel. Refer to the appropriate wiring diagram furnished with the cabinet for guidance. Electrical power of the current voltage, phase and ampacity must be supplied to the Blast Chiller. The Chiller must have its own separate electrical circuit breaker with no other equipment or appliance connected to that breaker. (Dedicated Circuit) See the cabinet data plate located on the interior wall for the electrical requirements.
CHECK LIST (WITH POWER TURNED OFF)
***** EXAMINE THE FOLLOWING BEFORE START-UP! ***** CAUTION:
these checks to avoid the possibility of unexpected injury !!!
1. Check that above installation recommendations have been adhered to. Pay particular attention to installation location for any potential excessive heat sources (oven, range, etc.) or inadequate air ventilation conditions which can cause compressor overheating problems and/or failure. If any such condition exists notify the owner to have the installer correct before continuing.
2. Check refrigeration tubing for damage and that they are not touching or rubbing against anything.
(continued)
Make sure the power to chiller is turned off prior to making
[ Section 2-Installation ] [ Page 12 ]
3. Make sure cabinet is sitting level with all four (4) casters (or legs) in contact with the floor.
4. Also make sure the door stays open when opened past 90 degrees.
5. Inspect magnetic door gasket to be sure it is making contact on all four (4) sides. Also make sure it is not cut, torn, twisted or otherwise deformed.
6. Check installation of shelves or pan slides .
7. Check electrical power source for correct voltage, phase and ampacity. Refer to cabinet data plate for requirements.
8. Remove electrical control box cover and check all wiring connections for a secure hold. On rare occasions, rough shipping and handling conditions can result in loosening of connections resulting in electrical problems.
9. Make sure all miniature circuit breakers are turned on.
10. Check all fan blades. They should turn freely without touching anything as they spin.
11. Check electrical power supply cord and plug for any damage and be sure it is not routed in a way that would permit anyone to trip over it.
[ Section 3-Operation ] [ Page 13]
GENERAL OPERATION OF BLAST CHILLER
All CRESCOR BLAST CHILLERS have 3 basic modes:
1. Normal refrigeration storage 1°C/34°F to 3°C/38°F
2. Blast chill hard –10°C/14°F
3. Blast chill soft 1°C/34°
Normal Cycle 1°/34°F to 3°C/38°F This is the storage temperature at which the food can be held.
Blast Chill Cycle (hard or soft) During the blast chill hard cycle the air temperature inside the cabinet should go down to approximately -10°C/14°F. This is for the timed or probe chilling cycle. Most applications will
use the hard cycle mode. During soft chill the air temperature stays above 0°C/32°F.
START UP INFORMATION
After you have completed all eleven (11) steps of the checklist, you are now ready to perform the following steps:
1. Sanitize the inside of the cabinet and probes.
2. Turn on BLAST CHILLER left standby button-Display panel will indicate cabinet
temperature.
3. There may be an indicator “A7”. This indicates that there has been a power failure.
4. Press the red “x” cancel button to cancel alarm.
5. Allow the cabinet to chill in standard refrigerator mode for at least 30 minutes.
6. Run BLAST CHILLER (See HOW TO OPERATE below) without food product to
ensure all equipment is performing correctly. Use warm pans of water and place probe tips in water to make sure the system is operating.
Do not submerge probes!
HOW TO OPERATE
The following instructions apply to all modes of CRESCOR BLAST CHILLERS
1. Turn on the chiller at least one half hour before use.
2. Check that the chiller is operating at storage temperature. Cabinet temp should be
40°F or lower.
3. Load the products to be chilled (see Loading Section page 4)
4. By pressing button ‘1’, select the ‘Chill’ mode
By pressing button ‘2’, select the desired blast function: "Hard Blast" or "Soft Blast".
5.
( Use Hard Blast unless otherwise advised.)
(continued)
[ Section 3-Operation ] [ Page 14 ]
6) By pressing button ‘3’, select the Timer for the desired duration or probed blast. Default to
probe blast unless it is known how long a product will chill.
7) If a variety of products are used make sure one probe is strategically placed near the top shelf, 1 in the center and 1 at a lower shelf. If a variety of products are used make sure one probe is in the largest item to be chilled. Place the CCBC-4-35 probe in the most difficult to chill item located on shelf 2 or 3.
8) When you are happy with your selected program press the "D" to start the blast cycle.
9) If you are not happy with your selection press the "x" button to cancel your 1/2/3. If cancelled repeat the above steps.
10) The blast chilling will begin.
TIP: You may open the door during blast chilling. This will not interrupt the cycle. If you add
additional food product make sure to use an Unused Clean probe in the product.
On completion of the blast chill cycle, when the product has reached 37°F, a buzzer will sound, and “DEF” will be displayed in the “CABINET TEMP” window of the control panel. “DEF” indicates the unit is defrosting. The blast chiller converts to a standard refrigerator.
During the defrost operation the temperature in the chiller will not exceed +3°C/38°F and it is therefore safe to leave products in the chiller during the defrost cycle.
NOTE: Product can be set for blast chilling at the end of the labor shift. The products will store
safely in refrigeration hold mode until the next shift up to 24 hours.
BLAST CHILL CYCLE/MODES
All BLAST CHILLERS allow the operator to use any of the 4 pre-programmed timed cycle and a probe control blast chilling cycle with the option of soft or hard blast.
PROBE CONTROLLED
The probe blast chill cycle functions with the internal probe(s) supplied. The probe monitors the core temperature of the food and will not permit the blast cycle to stop until the default temperature of 3°C/38°F is reached. The last product to reach 3°C 38°F will discontinue the blast chill cycle.
When controlling the cycle with the food probe, make certain that the probe or probes are located in the center of the product before the blast cycle is started. On BLAST CHILLERS equipped with three food probes the cycle will not finish until all three probes have reached the correct temperature.
CAUTION: Easier to chill items may actually freeze prior to the end of the blast chill cycle of the harder to chill item.
[ Section 3-Operation ] [ Page 15]
To activate a blast chill cycle you must:
1. Choose the required store mode with button 1
2. Choose the require blast type with button 2
(select hard blast unless all items chilling are delicate)
3. Choose the blast duration or probe with button 3
(select probe unless you know how long it takes the product to chill)
As each selection is made the indicator LED will illuminate to show what is chosen. Press the “D”to accept, or “x” to cancel.
At the end of the blast chill cycle there will be an audible alarm, which will cancel automatically after 15 minutes. (It may also be cancelled with the “x” button.)
After the blast chill cycle the cabinet will revert to a standard refrigeration mode appropriate to store the foods until ready to use or transfer.
LOADING OF PRODUCT
1. All food products should be placed in either a 2-1/2” hotel pan or a sheet pan.
2. With the exception of roasted meats, all products should not be more than 2” in depth. 1-1/2” is recommended for very dense items such a lasagna and beef stew.
3. There should not be more than 7 lbs. of product per shelf.
4. Roast meats should be cut in ½ or 1/3 to allow for more effective chilling.
5. All Products should be blast chilled uncovered unless a “skin” may be formed (in cream soups and sauces).*
6. Creamed soups and sauces should be covered with plastic wrap. The plastic wrap should be touching the product to allow quick chilling. *
7. Probe(s) should be placed in the center of the pan or roast meat.
DEFAULT MODE
To save time for repeated identical blast operations, the blast selections are remembered, so when 1-2-3 are pressed again, the selections automatically adopt the previous settings on the first push. So to repeat a blast chill mode, just push 1 2 3 “D”.
DEFROST
At the end of each cycle, the defrost cycle will automatically clear any ice from the evaporator.
During operation in storage mode a defrost will be performed automatically at the factory pre-set interval of 6 hours.
*see general rules of thumb pg. 30 for more information.
[ Section 3-Operation ] [ Page 16]
If a blast cycle is cancelled and the defrost thermostat is measuring 1°C/32°F or less, the BLAST CHILLER automatically goes into a defrost cycle.
When the BLAST CHILLER is in the defrost mode the “Cabinet Temp” window of the control panel will display “DEF” During the defrost cycle some fans will stop running. This is normal. When the defrost cycle is finished the compressor will run for approximately 90 seconds before the fans operate.
Following every defrost period there is a 3 minute period during which a blast cycle cannot be selected. This short interval is to allow for the water created by the defrost mode to dissipate. The cabinet is now ready to start another blast cycle if desired. During the defrost operation it is safe to leave products inside the blast chiller.
[ Section 3-Operation ] [ Page 17]
PRINTER
If equipped, the printer is activated after each blast cycle. The printer provides hard copy historical data of cabinet performance or warning tickets to archive or act upon. The following formats are available:
Midnight Ticket
At midnight, a ticket is automatically printed for archiving in the morning. The midnight ticket provides the following information:
- Time and date of printout and cabinet number
- Cabinet temperature at time of printout
- A graph of cabinet temperature over the preceding 24 hours
Demand Ticket
A ticket may be requested from the control panel by holding the printer 'On/Off' button for five (5) seconds. This ticket provides the same information as the midnight ticket except that up to seven (7) days of historical data are printed.
Alarm or Warning Ticket
A ticket is automatically printed if any condition is detected by the microcontroller, which may need attention. The print function may be terminated by pressing the printer 'On/Off' button.
Main Power Failure Ticket
If the main power fails for more than five (5) seconds a ticket is automatically printed which gives the time of power failure and the time at which power is stored.
Sensor Failure Ticket
If the controller detects that one of its sensors has failed, then a warning ticket will be printed.
Power Failure
A power cut does not cause the loss of any accumulated historical data and no re-programming is necessary. The controller's battery is continually charged and provides emergency back up under normal power failure conditions.
Installing New Paper and/or Ribbon Paper:
1. Lift Up and pull Out the printer cover.
2. Remove old cardboard roll, insert new paper roll in position so paper is fed unrolling from the bottom backside.
3. Fold paper end into a V shape and thread it through the slot over the ribbon cartridge.
4. Press "FEED" button on panel....paper should feed through slot, If not, redo step 4 and try
again until paper feeds through. Check for proper operation.
Ribbon:
To Remove:
Hold ribbon cartridge between thumb and pointer finger, pull gently but firmly out (towards you)
To replace:
Snap new cartridge in place and re-feed paper. Check for proper operation.
[ Section 4-
Maintenance ] [ Page 18 ]
CAUTION ! HINTS:
1. Turn Off Blast Chiller 1. Use the mildest cleaning product that will
2. Allow Cabinet to warm slightly. do the job
3. Do not hose Blast Chiller. 2. Always rub in the direction of polish lines to Avoid scratching the surface.
Wipe up spills as soon as possible. 3. Use only a soft cloth, sponge, fibrous brushes, Clean regularly to avoid heavy dirt buildup. Plastic pads for cleaning and scouring.
4. Rinse thoroughly with fresh water after every
Cleaning operation.
5. Always wipe dry to avoid watermarks.
SOIL
CLEANER METHOD
Routine Cleaning
Stubborn spots and stains
Probe
Hard Water Spots and Scale
Soap, ammonia or detergent* and water.
Mild abrasive made for stainless steel.
Antibacterial soap, ammonia or detergent* and water.
Vinegar.
* Mild detergents include soaps and non-abrasive cleaners.
1. Sponge on with cloth.
2. Rinse.
1. Apply with damp sponge or cloth.
2. Rub lightly.
1. Remove excess food from probe.
2. Clean and sanitize.
1. Swab or wipe with cloth.
2. Rinse and dry.
y
y
y
y
y
y
y
[ Section 5- Troubleshooting ] [ Page 19 ]
SERVICE & TROUBLESHOOTING
Setting or Resetting Time and Date
SWITCH FUNCTION IN SPECIAL SWITCH MODE
I/O ON/OFF SWITCH
1 When held in, displays the code for current parameter 2 Step back to previous parameter, and while held in displays the parameter
code. When released, displays the value of the parameter.
3 Advance to the next parameter. (same as above)
X
Increase the value of the current parameter. Decrease the value of the current parameter
To set the parameters complete the following steps:
1. This can only be entered from the panel OFF mode.
2. Press and
While Holding ke
3. You will now be in the programming mode.
HOLD IN
CODE PARAMETER
bss Blast Soft Stat 33 bhs Blast Hard Stat 12
bfs Blast Freeze Stat -16 sss Store Soft Stat 33 shs Store Hard Stat 33
sfs Store Freeze Stat -8 bsd Blast Soft Differential 35
bhd Blast Hard Differential 35
bfd Blast Freeze Differtial 35
ssd Store Soft Differential 35
sfd Store Freeze Differential 35
bd1 Blast Duration 1 (normally 30 min.) 30 bd2 Blast Duration 2 (normally 60 min.) 60 bd3 Blast Duration 3 (normally 90 min.) 90 bd4 Blast Duration 4 (normally 240 min) 240 cab Cabinet Number 1
ala Alarm Duration 900 (15 min)
ddc Defrost Duration for Cabinet Hex. Switch
dic Defrost Interval for Cabinet Hex. Switch
ddp N/A defrost Duration for PoD minutes, Set Manually
dip N/A defrost Interval Hours, Set Manually
det Defrost Target Temperature 39
yr Calander Year Setting Set Accordingl nth Calander Month Setting Set Accordingl da
hr Calander Hour Setting Set Accordingl
ute Calander Minute Setting Set Accordingl
Calander Day Setting Set Accordingl
SET UP PROCEDURE
any key
, press and release the
EXCEPT
the
ON/OFF
ON/OFF
key for three seconds.
key.
SET AT:
[ Section 5- Troubleshooting ] [ Page 19a ]
ALARM CODES
7-Segment Display
The left hand window shows the cabinet wall temperature. The right hand displays show the probe temperatures during a blast cycle, and are normally blank during store. If a probe fails it will indicate pf (probe failure) during a blast. Cab temp window also acts as a count up timer in probe blast.
If there is an alarm condition, the top probe display will show an alarm number a0 to a7 during store (see table below), but will still show the probe temperature during blast.
7-Seg Display
Alarm Condition
a0 AIR ON SENSOR FAILURE
a1 WALL SENSOR FAILURE
a2 FIN SENSOR FAILURE
a3 FOOD PROBE 1 FAILURE *
a4 FOOD PROBE 2 FAILURE
a5 FOOD PROBE 3 FAILURE
a6 SPARE
a7 POWER CUT DETECTED
* (Top Display On Front Panel Used For 3 Probe Systems)
Note: for each probe only one audible alarm and alarm printout is allowed to be issued each day. This is to prevent excessive paper use and noise nuisance in the event of an intermittent probe failure. However, repeated probe failures are displayed on the probe display window, (top window in the case of 3 probe panels)
[ Section 5- Troubleshooting ] [ Page 20 ]
Cabinet has no power to controller-display not lit:
1. Make sure the power is connected to the cabinet that the cord is plugged in on the models with power cord and plug.
2. Check main circuit breaker at power supply panel; make sure it is on.
3. Model CCBC-12-UA-100 only, has an "isolator" (disconnect) switch on the control box, make sure it is on.
4. Check circuit breakers inside cabinet control box; make sure all are on.
Check control power supply circuit safety klixon (some models). If tripped due to having exceeded 158°F, some models must be manually reset by pushing the red reset button (make sure power is turned off before doing this to avoid any unexpected injury!). Other models will reset automatically.
5. Check fuse on PC board.
6. Check for loose wiring.
7. Check plug in connectors for interconnecting cords and cables from main to front "Touch Pad" operators panel.
8. Defective communications ribbon cable.
9. Defective main or front PCB.
Cabinet has power, display shows "OFF". Turn cabinet "on" by pressing "OFF/ON" button.
1. Compressor not running: (a) Manually close compressor contactor (if utilized) temporarily to see if
compressor runs.
(b) If compressor runs, check compressor control circuit for problem.
(1) Is the Dual Pressure Control open?
- Check for correct settings
- Low or no refrigerant charge
- Liquid Line Solenoid Valve (if used) not opening?
(c) If the compressor doesn't run, check if you have power to compressor
terminals.
(1) If no power to terminals, trace back until power is found. Correct
problem.
- If single phase, check start relay and capacitor(s).
(2) If power is present at compressor terminals, check for stripped
compressor overload and/or "open" or grounded compressor-motor windings.
2. Compressor does run: (a) Compressor short cycles.
(1) Check DPC settings. Cut-in and/or differential may need to be
adjusted.
(2) Check refrigerant charge may be low.
- If low, or no charge, check for leaks, repair and recharge as necessary.
(3) Check if thermostatic expansion valve is feeding properly. (4) Check Chiller Store Thermostat ("St 1") and Differential ("Dt 1")
settings.
(5) Check the "fin" and "air on" thermocouples at main PCB to make sure
they are not interchanged.
(continued)
[ Section 5- Troubleshooting ] [ Page 21 ]
3. Compressor runs continuously. (1) Check compressor for "pumping" efficiency. (2) Door not closed tight or gasket leaking. (3) If no DPC, or if DPC set too low to open, check refrigerant charge
and/or thermostatic expansion valve for adequate feeding.
Cabinet has power, display shows "Sto", but load of hot food takes extremely long to chill:
1. "Sto" is the storage mode and cannot chill food properly. You must first choose a
"PROGRAM" and then press "BLAST" in order to make the machine do a blast chill cycle to quickly chill hot food.
In "BLAST" mode, unit runs, but doesn't chill the food fast enough.
1. Food too "thick" - limit 2 inches maximum for optimum performance.
2. Food too hot when placed inside - temperatures above 160°F increase pull-down time
proportionally.
3. Too much food - exceeding rated pounds of capacity increases pull-down time
proportionally.
4. Food covered (air trapped between food and cover is and insulator).
5. Container too large (distance from outside of container to center of food within is too
great, shouldn’t exceed 2 inches for optimum performance).
6. Container material is plastic (an insulator) instead of metal (a conductor).
7. If cabinet was off did not pre-chill before loading with hot food.
8. If using timed program, incorrect amount of time being selected.
9. Mechanical problem:
(a) Inadequate refrigerant charge. (b) Thermostatic Expansion Valve defective. (c) Evaporator fan(s) not working. (d) Evaporator coil iced (see below for possible causes). (e) Inadequate refrigeration (BTUH) capacity:
- Condensing unit ambient, or too high
- Condenser fan not working (if air cooled)
- Condenser dirty
- Compressor inefficient (or defective)
- Refrigerant line restriction
Evaporator coil iced:
1. Check how cabinet is being operated: (a) Placing load of hot food inside and merely closing door is improper use.
Doing this keeps unit in the storage ("Sto") mode resulting in extremely long pull-down times and does not initiate an automatic defrost. As a result the evaporator coil becomes heavily iced.
(b) Must run a "BLAST" cycle for automatic defrosting to occur.
(continued)
[Section 5-Troubleshooting ] [ Page 22 ]
2. Door not shut tight
3. Gaskets leaking
4. Check defrost heater operator (if used): (a) Defective heater (b) Blown fuse (if used) (c) Defective "klixon" if used
5. Check defrost settings: (a) Check defrost thermostat ("St 5") setting (b) Check defrost differential ("dt 5") setting (c) Check Defrost Period Switch on main PCB inside control box (d) Check Defrost Length Switch on main PCB control box.
6. Check that ambient temperature has not exceeded 100°F or 100% humidity.
Display reads - 58° F
1. Thermocouple is "open" : (a) If food probe, check the make sure it's plugged into probe receptacle properly (b) Check for loosened thermocouple wire connection at all connections (c) Check for broken or cut thermocouple wire (d) Temperature display not believable - responds in reverse:
- Polarity of thermocouple wire is reversed
Evaporator won't run:
1. Breaker not on (if equipped)
2. Motor overload tripped (if equipped)
3. In post-defrost "Drip" period
4. "Fan door" switch is open (if equipped)
5. Blown fuse (if used)
6. Defective contactor (if equipped)
7. Motor defective
Printer problems (if equipped) :
1. Printer doesn't run: (a) "Link" (jumper) on main PCB not installed (b) Damaged communications "ribbon" cable (c) Defective printer (d) Defective PCB
2. Printer "runs", but no paper comes out: (a) Check if paper roll is loaded (b) Check for jammed paper tape -
- Before loading a new roll, make sure free end of tape is pulled completely away from the roll. Remove any paper residue. (The residue will undoubtedly result in a paper jam).
- Carefully remove any paper residue from printer platen, otherwise another jam could occur.
(c) Check for proper tape feed
3. Printer runs, but paper comes out with no printing: (a) Check if printer has ribbon cartridge installed (b) Check ribbon - condition may be out of ink, dried out, or torn
[ Section 5-Troubleshooting ] [ Page 23 ]
(c) Check make sure ribbon cartridge is properly installed - both sides snapped in
place
4. Printer is printing backwards and all characters reversed (a) Paper tape is feeding incorrectly over top of printer ribbon. This can readily
occur when inserting a ribbon cartridge with paper tape still protruding from the printer. The ribbon must be on top of the paper in order to print
correctly.
5. Paper rolls and ribbon cartridges are available from CresCor Authorized Parts
Distributors.
Odors inside cabinet:
1. Spilled food inside - clean as required
2. If not being used for a long period of time, turn off, clean interior and keep door open
to ventilate. Alternatively after cleaning, place and odor absorbent such as baking soda inside with the door kept closed. Remove before restarting.
Alarm conditions:
1. Cabinet wall temperature above 38°F more than 60 minutes
2. Defrost termination on time instead of temperature
3. Compressor overheating (if temperature is greater than 217°F for 1 minute)
4. Compressor run (if the compressor runs continuously for more than 6 hours in either
blast mode or storage mode)
5. Faulty sensor (including food probe)
6. Loss of power for 5 seconds or more
7. Dead battery
Food dried out
1. Uncovered containers
2. Left in storage too long
Food frozen
1. Too long blast cycle (a) Choose a shorter timed program (b) Use the probe program
2. Uneven food portions-thinner foods can freeze by the time thicker portions reach
temperature
3. Monitor temperatures more frequently if uneven food loads and remove those when
reaching end temperature
4. Food probe defective
5. Stat 1 set too warm
Food not cold enough
1. Timed cycle too short
2. Stat 1 set too warm
3. Food probe tip not in center of food
4. Defective probe
[ Section 6 – Parts and Drawings ]______________________ __ [ Page 24 ]
Parts List and Breakdown Drawing of Blast
Chillers
[ Page 25 ]
[ Page 26 ]
PARTS LIST CCBC-4-35 BLAST CHILLER 208V 60HZ SINGLE PHASE
Drawing Number Description Part Number
1 COMPRESSOR CAJ 4492Y R134A WCOMP 345
1a CONDENSER 3X11X21 WCOND 250
1b DRIER 1/4 X 3/16 SWEAT T R134A WDRIER 110
1c SIGHT GLASS 1/4" SWEAT WSIGHT 020
2 RECEIVER 2.2 L WRECEIVER 060
3 EXPANSION VALVE BODY TEN 2 R134A WVALVE 196
3 1/4" SOLDER ADAPTOR WVALVE 198
3 ORIFICE NO. 3 WVALVE 201
4 CONDENSOR FAN MOTOR 16 WATT WMOTOR 270
4 CONDENSOR FAN BLADE 10" 27° PITCH WBLADE 070
5 CONDENSOR FAN PLATE WCFP/WBC35/99/1
6 EVAPORATOR FAN 315MM AXIAL FAN (ZIEHL EBM) WMOTOR 420
7 EVAPORATOR WIRE FAN GUARD 50MM DEEP WGUARD 090
8 EVAPORATOR FAN PLATE WEFP/WBC35/99/1
9 RACKING WLR/WBC35/99/1
10 FOOD PROBE WPROBE 100
10a FLANGED SOCKET WPROBE SOCKET 010
11 UNIT COVER (TOP) WUCT/WBC35/99/1
11a UNIT COVER (BOTTOM) WUCB/WBC35/99/1
12 GASKET: 680MM X 430MM WGASKET 905
13 HINGE PLATE: R7 OPAL-TOP WHINGE 020
14 HINGE: SPRING LOADED WHINGE 290
15 STANDARD DOOR WWBC35 STD DOOR/99/1
16 EVAPORATOR 4X13X17 WEVAP 485
17 DRIP TRAY WDT/WBC35/99/1
18 DEFROST HEATER 3 BEND 300W WHEATER 030
19 NEW DOOR NYLON WDOOR NYLON NEW
20 LADDERRACK MOUNTING BLOCK WLADDERACK 020
21 SCREW: M6 X 12 POZI PAN ZINC T/T WSCREW 140
22 WBC/SPEC B1 WITHOUT PT. NO 4253 WLABEL 701
23 AARDWARE FRONT PANEL WAARDWARE 010
23 AARDWARE BACK BOARD NO PRINTER WAARDWARE 030
23 1M RIBBON TO CONNECT TO FRONT & BACK WLOGGER RIBBON 010
24 LEGS: S/S 4" SHORT STUD C/C PLATE WLEG 050
25 KLOCKNER MOELLER DIL 00M 190V 50HZ/220V 60HZ WCONTACT 190
26 6MM X 25MM ZINC POZI PAN TAP TIGHT SCREWS WSCREW 180
27 S/S/ SLIDE 585MM (2 OFF PER SLIDE 276MM) WS/SLIDE 06O
28 LATCH: UNIT COVER (CLIP) WLATCH 030
29 STRIKE: UNIT COVER (CLIP) WSTRIKE 010
30 8MM X 20MM ZINC SET SCREWS WSCREW 585
31 REAR COVER WRC/WBC35/99/1
32 HOT GAS VAPORIZER WHGV/335X185/88/1
33 PLUG WPLUG 170
34 CORD WCABLE 520 35 LADDERRACK MOUNTING BLOCKS WLADDERACK 010
[ Page 27 ]
[ Page 28 ]
PARTS LIST CCBC-12-75 BLAST CHILLER 208V 60HZ SINGLE PHASE
Drawing Number Description Part Number
1 COMPRESSOR FH4518Y 208/220V 60HZ WCOMP 365
1 CONDENSER 4X17X17.5 WCOND208
3 EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL WFAN 115
3 FLAT GUARD WGUARD 080
3 1.5 UF CAPACITOR 230V 60HZ WCAPACITOR 050
4 EVAPORATOR 4X12X41 WEVAP311
5 SIGHT GLASS 3/8" SWEAT WSIGHT 010
6 DRIER 3/8" SUITABLE FOR H134A WDRIER 080
7 EXPANSION VALVE TEN 2 R134A WVALVE 196
7 3/8" SOLDER ADAPTOR 068-2060 WVALVE 197
7 ORIFICE NO. 3 WVALVE 231
8 DEFROST HEATER 2X500 WATT 1 BEND WHEATER 400
9 VAPORIZER HEATER 115 WATT 3 BEND WHEATER 010
10 HEATER WIRE 4.35M 240V (57 WATT) WHEATER WIRE 340
11 KLIXON 14T31 30210 L13C 9651 WSTAT 410
12 FOOD PROBE WPROBE 1OO
13 PROBE SOCKET WPROBE SOCKET 010
14 AARDWARE FRONT PANEL C/W PRINTER WAARDWARE 020
14 AARDWARE BACK BOARD WAARDWARE 010
14 1.5M RIBBON TO CONNECT TO FRONT & BACK WAARDWARE RIBBON 020
14a LABEL: 3 PROBE F° WLABEL 746
15 HIGH / LOW PRESSURE STAT WSWITCH 360
16 NEW DOOR NYLON WDOOR NYLON NEW
17 HINGE: SPRING LOADED WHINGE 290
18 SWITCH: THERMAL HEATED 331-528 WSWITCH 200
19 CASTOR 6" W/BRAKE WCASTOR 040
19a CASTOR 6" NO BRAKE WCASTOR 030
20 HINGE PLATE: R4 OPAL/T2U WHINGE 070
21 LADDERACK BLOCKS WLADDERACK 020
22 UNIT COVER WUC/WBC75/99/1
23 CONTROL PANEL WCP/WBC75/99/1
24 DOOR WWBC75 STD DOOR/99/1
25 GASKET 1295MM X 565MM WGASKET 900
26 LADDERACK (1SET) WLR/WBC75/99/1
27 DRIP TRAY WDT/WBC75/99/1
28 BAFFLE PLATE WBP/WBC75/99/1
29 EVAPORATOR FAN PLATE WEFP/WBC75/99/1
30 EVAPORATOR BAFFLE PLATE WEBP/WBC75/99/1
31 CONDENSER FAN PLATE WCFP/WBC75/99/1
32 BIGHEAD M/4T38 6X26 WBIGHEAD 010
33 SCREW M6X25 POZI COUNTERSUNK WSCREW 200
34 SCREW M6X25 POZI PAN ZINC T/T WSCREW 180
35 ELECTRIC VAPORIZER WEV/800X235/88/l
36 CONDENSOR FAN 120W MOTOR WMOTOR 410
36 3.0 UF CAPACITOR 230V 60HZ WCAPACITOR 060
37 CONTROL PANEL BOTTOM WCPB/WBC75/99/1
38 HINGE: BLACK PLASTIC WHINGE 560
39 KLOCKER MOELLER DIL OM 190V 50HZ/220V 60 HZ WCONTACT 160
40 RECEIVER 2.2 LT WRECEIVER 060
41 BIGHEAD 316-F2/ST38 M5X5 WBIGHEAD 060
42 MAINS PLUG WPLUG 160
43 MAINS LEAD WCABLE 510
44 LINER BASE WS/SBASE 180
45 TRAY SLIDE WTS/WBC75/99/1
46 CONTROL PANEL REAR COVER WCPRC/WBC75/99/1
[ Page 29 ]
[ Page 30 ]
PARTS LIST CCBC-12-UA-100 BLAST CHILLER 208V 60HZ 3 PHASE
Drawing Number Description Part Number
1 COMPRESSOR TFH 4524Z 208/230V 60HZ WCOMP 833
2 CONDENSER 4X17X17.5 WCOND208
3 EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL WFAN 115
3 FLAT GUARD WGUARD 080
3 1.5 UF CAPACITOR 230V 60HZ WCAPACITOR 040
4 EVAPORATOR 5X45X16 WEVAP348
5 SIGHT GLASS 3/8" SWEAT WSIGHT 010
6 DRIER 3/8" WDRIER 080
7 EXPANSION VALVE TES 2 R404A WVALVE 191
7 3/8 SOLDER ADAPTOR 068-2060 WVALVE 197
7 ORIFICE NO. 3 WVALVE 231
8 DEFROST HEATER 2X500 WATT 1 BEND WHEATER 500
9 VAPORIZER HEATER 115 WATT 3 BEND WHEATER 010
10 HEATER WIRE 4.35M 240V (57 WATTS) WHEATER WIRE 340
11 KLIXON 141T31 30210 L13C 9651 WSTAT 410
12 FOOD PROBE (3 EACH) WPROBE 1OO
13 PROBE SOCKET WPROBE SOCKET 010
14 AARDWARE FRONT PANEL C/W PRINTER WAARDWARE 070
14 AARDWARE BACK BOARD WAARDWARE 040
14 LOGGER CHIP WLOGGER CHIP 170
14 1.M RIBBON TO CONNECT FRONT & BACK WAARDWARE RIBBON Sm
14a NEW BLAST CHILL 3 PROBE C/W PRINTER WLABEL 918
15 HIGH / LOW PRESSURE STAT WSWITCH 360
16 NEW DOOR NYLON WDOOR NYLON NEW
17 HINGE: SPRING LOADED WHINGE 290
18 SWITCH: THERMAL HEATED WSWITCH 200
19 CASTOR 6" W/BRAKE WCASTOR 040
19a CASTOR 6" NO BRAKE WCASTOR 030
20 HINGE PLATE: R4 OPAL/T2U WHINGE 070
21 LADDERACK BLOCKS WLADDERACK 020
22 UNIT COVER WUC/WBC1I0/99/1
23 CONTROL PANEL WCP/WBC1I0/99/1
24 DOOR WWBC110 STD DOOR/99/1
25 GASKET: 1354MM X 627MM C/C WGASKET 895
26 LADDERACK (1SET) WLR/WBC110/99/1
27 DRIP TRAY WDT/WBC110/99/1
28 BAFFLE PLATE WBP/WBC110/99/1
29 EVAPORATOR FAN PLATE WEFP/WBC110/99/1
30 EVAPORATOR BAFFLE PLATE WEBP/WBC110/99/1
31 CONDENSER FAN PLATE WCFP/WBC110/99/1
32 BIGHEAD M/4T38 6X26 WBIGHEAD 010
33 SCREW M6 X 25 POZI COUNTERSUNK WSCREW 200
34 SCREW M6 X 25 POZI PAN ZINC T/T WSCREW 180
35 ELECTRIC VAPORIZER WEV/800X235/88/l
36 CONDENSER FAN 120W MOTOR WMOTOR 410
37 CONTROL PANEL BOTTOM WCPB/IWBC/110/99/1
38 HINGE: BLACK PLASTIC WHINGE 560
39 KLOCKER MOELLER DIL OM 190V 50HZ/220V 60HZ WCONTACT 160
40 RECEIVER 3.3 LT WRECEIVER 070
41 BIGHEAD 316-F2/ST38 M5X5 WBIGHEAD 060
42 CONDENSER FAN COWL (BEHIND FAN) WCFC/WBC110/99/1
43 UIVERSAL ANGLES (24 PER CABINET) WSLID/WBC110/99/1
44 CONTROL PANEL REAR COVER WCPRC/WBC110/99/1
45 THERMOCOUPLE TYPE T PTFE 2M WTHERM 230
46 SHELF GARNET WHITE COATED (X12) WSHELF 185
General Rules of Thumb [ Page 31 ]
Pre-Chill the cabinet for thirty (30) minutes before you do first load.
(to remove interior residual heat)
Doubling the food thickness triples the pull-down time.
Don't stack food or containers on top of or alongside of each other.
(this increases the "thickness)
Covering the food increases pull-down time by 10%-30%.
Pull-down rate initially is about 2°F per minute and approaching final temperature is about 2
minutes per degree F.
"A watched pot never boils"
Factors affecting blast chill pull-down times:
(A) Initial food temperatures (The hotter the initial food temp., the longer the pull-down time)
(B) Final food temp. (the colder the final temp., the longer the pull-down time)
(C) Food "thickness"(the greater the distance from geometric "core" center of food to its
surface, the longer the pull-down time)
(D) Food density (the greater the density, the longer the pull-down time)
(E) Container surface area(the smaller the surface area, the longer the pull-down time)
(F) Container material (metals are conductors which will shorten the length of pull-down
time, while plastics are insulators which will increase pull-down time)
(G) Covering material (metal preferred, same reasons as above)
(H) Covering method (Covering which is in direct contact with the food will pull-down
quicker than covering that is stretched tight leaving a "dead air" space between cover and food. Air acts as an insulator and will increase the pull-down time)
(I) Amount (weight) of food put in as compared to rated capacity (exceeding rated
capacity will lengthen the time of pull-down)
Contact Information [ Page 32 ]
Please Send Serial registration information to :
Fax: (800) 378 – 8333
E-mail to: parts&service@crescor.com
Or
Mail To:
CresCor
5925 Heisley Road
Mentor, OH 44060
Toll Free: 877-273-7267 Fax: 440-350-7267
See us online at:
http://www.crescor.com
Questions?
Call and Speak To One Of Our
Friendly Service Counselors:
Ellery @ Ext. 319
Pat @ Ext. 214
[ Page 33 ]
Notes __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________
Date Purchased ________________
Date of Installation ________________
Serial Number _________________________
Model Number _________________________
[Page 34]
MEATS
Roasted Meats
Roasted meats should be prepared according to the recipe using roast guidelines for each product.
Cook according to recipe. If sauce or gravy is required, it should be prepared and chilled separately from the portioned meat.
Turkey/Chicken
Cook turkey or chicken whole or breasts according to directions to 170° F. (76° C.). Blast chill immediately. Slice product to a 1/4" thickness, single layered. Pre-cooked turkey products do not require roasting.
*
Roast Beef (top round)
- Follow recipe and roast guidelines. Recommended doneness for rethermalization is about 140° F. (60° C.). Top round should be quartered and placed in the blast chiller. If roast beef is used for cold sandwiches, the end cooking temperature may be higher. If medium doneness is desired, roast to 150° F. (65° C.). Do not overcook.
Pork Roast
- Follow recipe and roast guidelines. Recommended doneness for rethermalization is 165° to 170° F. (74° to 76° C.). Do not overcook or product will be dry.
Lamb Roast
- Follow recipe and roast guidelines. Recommended doneness for
rethermalization is 155° F. (68° C.). Do not overcook.
Proportioned Meats (hamburger patty, pork chop, Salisbury steak, etc.)
Steak (filet, strip, ribeye)
- Broil steak to medium rare or preferred stage of
doneness. Blast chill immediately.
Salisbury Steak
- Bake to 165° F. (74° C.) Drain well, remove all grease. Blast
chill. Add gravy after steak is chilled.
Pork Chops/Cutlets
- Breaded, baked, or broiled chop is heated only to 165° F.
(74° C.) and blast chilled immediately. Add sauce or gravy after chilling.
[Page 35]
Seafood
- Prepare all fish fillets according to recipe for breaded, baked, broiled,
Fish steamed, etc. Be careful not to overcook. Blast chill immediately.
Shrimp/Scallops/Shellfish immediately. Be careful not to overcook. If prepared with a sauce (creole, etc.), cook the sauce separate and mix together prior to retherm.
Casseroles and Stews
Stew and casseroles are very successful in cook/chill and rethermalization. Most recipes should require little change for cook/chill. Products should be moist but hold form when plated. Prepare and blast chill in 2-1/2" full pans.
Lasagna Prepared from scratch, follow the recipe; do not overcook. Blast chill.
Beef Stew/Stroganoff, etc. recipe. Blast chill.
Chicken/Turkey/Beef Pot Pie sauce separately from the crust, pastry, or biscuit. Top product after chilling or at point of rethermalization.
Stir Frys
Pasta Casserole (Mac & Cheese, Turkey Tetrazzini) from pasta. Blast chill. Mix product together chilled and rethermed.
Sauces and Gravies
For conventionally prepared gravies and sauces, substitute a portion of the flour or cornstarch with a modified starch. A substitute of 30 to 50% by weight is recommended. In preparing these sauces and gravies with the modified starch, the product must reach 170° F. (76° C.) and be held at the temperature for a minimum of 5 minutes. If this is not done, the gravy or sauce will thicken during the chilled storage. To reduce the risk of rancidity during refrigerated storage, use broth bases rather than meat or poultry drippings. Commercial gravy or sauce bases contain modified starches and can be substituted for conventionally prepared products.
Sandwiches/Specialty Items
See CresCor Retherm Oven Time and Temperature chart on Page 60 in CresCor cookbook.
- Brown off convenience lasagna to remove extra moisture and blast chill.
– Sauté / steam until meat is done and vegetables are crisp.
- Prepare according to recipe and blast chill
- Cook/steam meat until tender. Prepare as stated in
- Prepare the chicken/turkey/beef and vegetable
- Prepare sauce separately
[Page 36]
SOUPS
Conventional Soup
Prepare conventionally. For creamed soups, substitute a modified starch for a portion of the thickening agent by 30 to 50%.
Canned Soup
No cooking is necessary for broth based soups. Cream soups should be diluted with milk or water, mixed completely, and blast chilled.
Frozen Soup
Follow instructions on the soup container for preparing soup, blend thoroughly, and blast chill.
VEGETABLES
Add seasonings to vegetables prior to panning. If margarine is added, a more even distribution will occur with liquid margarine.
Frozen Vegetables
Frozen vegetables do not require cooking before rethermalization.
For bulk rethermalization, vegetables do not need to be cooked or blast chilled before service and should be prepared as in conventional production.
Canned Vegetables
Canned vegetables do not require any cooking. All canned vegetables can easily be bulk rethermed with little liquid remaining.
Fresh Vegetables
Many fresh vegetables can be used in cook/chill. The desired texture of the product will determine the preparation procedure.
Zucchini/Yellow Squash
Steam or stir fry to desired consistency then blast chill.
Broiled Tomato and blast chill immediately. Tomato will continue baking during rethermalization.
Slice in half and sprinkle on topping. Broil to brown topping
[Page 37]
Broccoli/Cauliflower/Green Beans/Carrots bite size and broccoli and cauliflower in flowerets. Steam to desired doneness, then blast chill.
Stuffed Vegetables (eggplant, zucchini)
shell and blast chill or place in ice bath. Stuff vegetable shell and blast chill to bring temperature down from time of assembly.
Grilled Vegetables
Grill according to recipe. Place in 2-1/2" pan and blast chill.
POTATOES
Occasionally, "graying" or slight darkening of the cut surfaces of some cooked potatoes will occur during chilling. This is an oxidation reaction and varies with the variety of potato, soil, and weather conditions. Varieties that most often exhibit darkening are: Irish, Ontario, Norland, and Red Pontiac.
Potatoes are fully cooked before blast chilling. Canned potatoes, well drained, can be used without further cooking.
Mashed Potato (flakes or powder)
Follow recipe according to the package. Product should be smooth, easy to scoop, and hold its form loosely at the point of blast chilling. Product should stay at that consistency after blast chilling. If the product becomes stiff or dry, add water and stir into product.
Mashed Potato (fresh)
Follow recipe. Potatoes should be very soft before mashing and adding liquid. Follow same consistency rule as for flake or powder potatoes. Cover with plastic and blast chill. Fresh mashed potatoes should not be made more than 48 hours in advance to prevent discoloration.
Baked Potato
Depending on the size of the potato, cut in half or fourths. Boil, steam, or bake potato to complete doneness, then chill.
French Fried Potato
For best results, oven bake vs. deep fat frying is recommended. Steak fries are preferred over a crinkle cut or shoe string potato. Tator tots and potato wedges also rethermalize well. Bake according to recipe or package and blast chill.
Prepare green beans and carrots in
Prepare stuffing and blast chill. Steam
[Page 38]
RICE
Prepare according to standardized recipe, then blast chill. If rethermalized product is dry, liquid may be added.
PASTA AND NOODLES
Cook to al dente, rinse well with cold water, then chill. Chill in 2-1/2" pans with water with ice added. Drain partially before retherming. The best way to heat pasta is to run it under hot water or dunk it into boiling water for 30 seconds.
FRIED FOODS
It is difficult to achieve a crispy, chewy fried product with an advanced preparation food process. For best results, oven frying is recommended. If deep fat frying is still your choice, use crumb breading instead of batter. Fry in clean, hot oil, and drain well before chilling. Do not attempt to prepare further than one day ahead to avoid excess moisture. Use meat items with little or no bone to get a drier product. Fried foods should be produced conventionally when possible.
CEREALS
Cooked cereals such as oatmeal and grits continue to thicken when chilled and held under refrigerated storage. To obtain a desirable product, follow the following procedures.
Cream of Wheat / Grits
Prepare recipe according to the directions. At the end of cooking, add 50% more water and use a wire whip to stir in the water. Blast chill. The product should be the consistency of pudding. If it is not, add water. Use a wire whip and stir to a pudding consistency.
Oatmeal
Add 30% more liquid and follow recipe.
EGGS
Poached Egg
If a poached egg must be served, cook to firm stage. Procedure:
• Spray a 1/2 steam table pan (2" deep) with any type release agent (e.g. Pam™)
• Fill with cold water, add 1/4 cup vinegar.
[Page 39]
• Add a 2" perforated insert to pan.
• Break eggs (25-30) in separate bowl and slip onto the 1/2 pan insert.
• Steam a maximum of 3 minutes (time should be tested at each facility as equipment performance will vary at each location).
• Lift perforated insert out of pan and plunge into ice water to retard cooking. The whites will still have a wet, glossy look, but should hold shape.
• Lift eggs out with slotted spoon and drain well before plating on trayline. Chill and store until trayline.
• Eggs could be left to chill on perforated insert, drain well.
Scrambled Egg
A pasteurized egg product is recommended. Prepare to a soft, loose consistency. Remove from heat source, cover with plastic wrap, and immediately blast chill.
Omelets
Frozen convenience product must be fully tempered prior to assembly. For omelets prepared conventionally, follow existing standardized recipe. Omelet should be slightly undercooked, then blast chilled.
Hard Cooked Egg
Cook in usual manner and chill immediately. Store covered in walk-in cooler.
PANCAKES/FRENCH TOAST/WAFFLES
For pancakes/French toast prepared conventionally, shingle, stack, and blast chill for a short period of time (approximately 15 minutes). French toast made with Texas toast blast chills and retherms with the best quality.
BREAKFAST MEAT
Sausage
Sausage patties are preferred over links for best heating. Cook sausage to 165° F. (74° C.), then drain well. Blast chill.
Bacon
Cook to point of service. Presentation is best if bacon is cooked to the crisp stage, drained, and patted dry with paper towels to remove excess fat. Blast chill.
[Page 40]
BREAKFAST BURRITOS/CREPES
Burrito and crepe filling is prepared conventionally and chilled. When filling is chilled, then fill crepes and burritos. Blast chill filled products.
BREAKFAST SANDWICHES
Prepare sandwich filling separately and chill. Assemble sandwiches, wrap, and blast chill for additional 15-20 minutes.
HASH BROWNS/OVEN FRIES
For both convenience and freshness, prepare to the point of complete doneness, then blast chill. Product should not be too dry.
*Please note: The internal temperatures may continue to increase in the beginning of the blast chill cycle.