INSTALLATION INSTRUCTIONS
for INFRA-RED WARMERS IFW-66 Series
ELECTRICAL SPECIFICATIONS:
120 Volts; 250 Watts; 2 Amps.
240 Volts; 275 Watts; 1 Amp.
UL AND CSA REQUIRE:
Wires of warmer are to be connected to
75°C wire.
Wires to be installed with conduit
Warmers are not to be installed closer
than 1” from a wall.
Warmers cannot be closer than 16”
above a combustible surface
HOW TO INSTALL: (See Figure)
NOTE: Outlet box (7) and screws (5) are to be furnished by customer.
IFW-7066-007 FL-1668
Rev. 5 (1/98) Page 1 of 1
Part Identification: (See figure)
1. Assembly socket
2. Strap-Ceiling
3. Cord
4. Canopy Kit
5. Crown Plate
6. Ground “GND” Screw
1. Remove the two screws from the crown plate (5) and pull off the canopy (4).
2. Run cord (3) up through threaded nipple.
3. Cut cord to desired length.
4. Mount the strap (2) to the electrical outlet box with two screws.
5. Attach ground wire from the ceiling to the “GND” hold in the strap (2) with green screw (6).
6. Wire the warmer leads to the outlet box leads.
7. Screw canopy (4) to the crown plate (5) with two sheet metal screws.
8. Screw the lamp into the socket.
REPLACEMENT PARTS:
Lamp, Red (120V) 0820-001 Lamp, White (120V) 0820-033 Lamp, Red (240V) 0820-014 Socket 0822-030 Switch 0808-002 Cord 0810-042 Canopy Kit 7071