All are designed for AC service.
HOW TO INSTALL UNIT:
1. Place cabinet near warm ovens. Do NOT put in
drafty areas or near ventilating systems.
120 1920 16.6 60 1 5-20P
208 2000 9.6 60 1 6-15P
240 2000 8.6 60 1 6-15P
Rev. 10 (11/13) Page 1 of 4
2. Plug cord end into proper wall outlet.
3. Fill water pan with 2 qts. (1.8 liters) of clean, hot
water.
HOW TO PROOF:
1. Fill water pan (See “How to Install”)
2. Push “POWER” switch to “ON.” The yellow light
will come on.
3. Push “MODE SELECTION” switch to “PROOF”.
The yellow light will come on.
4. Turn “HUMIDITY” dial to No. 8.
5. Turn “AIR” dial to “OFF”.
6. Preheat for 30 minutes.
7. Put fresh or fully thawed dough into cabinet.
NOTE: The cabinet temperature will drop temperature
inside cabinet if cold dough is added.
Do NOT put frozen dough into cabinet
CONTROL PANEL PARTS IDENTIFICATION
1. Switch - Power 5. Yellow Light - Proof
2. Yellow Light - Power 6. Red Light - Heat
3. Thermostat - Humidity 7. Switch - Mode Selection
4. Thermostat - Air 8. Thermometer
NOTE: No. 8 setting will give you an approximate
temperature of 95°F (35°C), and 90-95%
humidity. Experiment with different
“HUMIDITY” and “AIR” settings to get the
exact temperature and humidity you need. The
thermometer shows the temperature inside the
cabinet.
NOTE: Check water level in water pan if you are
proong longer than 90 minutes. Fill with
clean, hot water.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Proof/Hot
Cabinets
FL-2306
Rev. 10 (11/13) Page 2 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 120PH and 121PH “D” Series Proof/Hot Cabinets
HOW TO HOLD
1. Push “POWER” switch to “ON.” The yellow light
will come on.
2. Push “MODE SELECTION” switch to “HEAT.”
The red light will come on.
3. Turn “AIR” dial to temperature needed.
NOTE: No. 8 is about 175°F (79°C).
No. 6 is about 165°F (74°C).
Proper food holding temperature
is 140°F (60°C) or higher.
4. Preheat cabinet for 30 minutes.
5. Put food into cabinet.
5925 Heisley Road • Mentor, OH 44060-1833
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
HOW TO TURN UNIT OFF:
Push “POWER” switch to “OFF” position.
HOT UNIT REMOVAL INSTRUCTIONS:
1. Unplug power cord from wall outlet.
2. Pull entire unit out the front of the cabinet.
BEFORE cleaning the
WARNING
1. Allow cabinet to cool.
cabinet:
DELIME OR DESCALE RESERVOIR
CAUTION
PARTS AS REQUIRED TO PREVENT
2. Remove Hot unit from cabinet.
3. Do NOT use abrasives or harsh chemicals.
DAMAGING BUILD-UP. WARRANTY
COVERAGE MAY BE AFFECTED
WITHOUT PROPER CLEANING.
HOW TO CLEAN THE CABINET:
• The door is a polycarbonate panel in a powder coated frame.
Use mild detergent and water, rinse and wipe dry with a soft cloth.
• The cabinet body (inside and outside) is aluminum.
THIS CABINET BODY IS INTENDED TO BE CLEANED USING HIGH PRESSURE CLEANING
METHODS.
Wipe up spills as soon as possible and clean cabinet regularly to avoid heavy dirt build-up.
Detergents will assist in removing dirt, grease and stains. Only use detergents recommended for pressure
washers.
• Empty water pan at least once a week.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com