Cres Cor 121-PH1816, 120-PH1836 240, 121-PH-1816 240 User Manual

Proof/Hot
Cabinets
FL-0604
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 120-PH and 121-PH Series Proof/Hot Cabinets
120-PH-1836 121-PH1816 120-PH1836 240 121-PH-1816 240
All are designed for AC service.
HOW TO INSTALL UNIT:
Place cabinet near warm ovens. Do 1. NOT put in drafty areas or near ventilating systems. Plug power cord into proper wall outlet. 2. Fill water pan (following steps a-c).3.
Use of treated or
CAUTION
operation and to maintain warranty.
soft water may be required for proper
120 2025 16.8 60 1 5-20P 240 1925 8 60 1 5-15P
Rev. 20 (3/10) Page 1 of 4
HOW TO PROOF, continued:
Turn “RESERVOIR THERMOSTAT” to #9 and 5. close the door.
NOTE: No. 9 setting will give you an approximately
90-95% humidity at 95°F (35°C). Experiment with different settings to get the exact temperature and humidity you need.
Thermometer shows the temperature inside the cabinet.
a. Lift off cover. b. Fill with 3.5 qts. (3.3 liters) of water. Replace cover. c. Adjust vents on cover to half open.
HOW TO PROOF:
Push switch to “HUMIDITY”. Yellow power light 1. will come on. Turn “RESERVOIR THERMOSTAT” to #10. Red 2. heater light will come on. Preheat cabinet for 30 minutes.3. Put fresh or 4. fully thawed dough into cabinet.
NOTE: The cabinet temperature will drop temperature
inside cabinet if cold dough is added.
Do NOT put frozen dough into cabinet
PARTS IDENTIFICATION
1. Water Pan (Reservoir) 6. Switch: ON/OFF
2. Reservoir Heater & Probe
3. Water Pan Cover 8. Air Thermostat
4. Reservoir Thermostat 9. Air Probe
5. Y ellow POWER light; Red HEATER light for Reservoir
7. Yellow POWER light; Red HEATER light for Air
10. Air Heater
11. T unnel Heater
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Proof/Hot
Cabinets
FL-0604
Rev. 20 (3/10) Page 2 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 120-PH and 121-PH Series Proof/Hot Cabinets
NOTE: Check water level in water pan if you are
proofi ng longer than 90 minutes. Fill with clean, hot water.
DRY PROOFING:
Turn air thermostat to #3 for 100°F (38°C) or higher.
HOW TO HEAT CABINET:
Push switch to “AIR”. The 1. Red indicator will light. Turn “AIR THERMOSTAT” to temperature 2. needed.
NOTE: No. 8 is approx. 175°F (79°C).
No. 6 is approx. 145°F (63°C). No. 4 is approx. 115°F (46°C).
Proper food holding temperature is 140°F (60°C) or higher.
Preheat cabinet for 30 minutes.3. Put food into cabinet.4.
FOR HUMIDITY:
Add water to water pan1. Push switch to “HUMIDITY” for a few minutes.2.
TO TURN UNIT OFF: Push switch OFF.
5925 Heisley Road • Mentor, OH 44060-1833
MAINTENANCE HOT UNIT REMOVAL INSTRUCTIONS:
Unplug power cord from wall outlet.1. Remove two (2) screws from back of cabinet, one 2.
(1) above the receptacle and one (1) higher up, holding the top of the tunnel. Slide the entire unit out front of the cabinet, tilting 3. it to clear the tie rod.
BEFORE cleaning
WARNING
the cabinet:
Allow cabinet to cool.1. Remove Hot unit from cabinet.2. Do NOT use abrasives or harsh 3.
chemicals.
Cleaning hints:
Wipe up spills as soon as possible.1. Clean cabinet regularly to avoid heavy dirt build-up.2. Make a test spot with cleaner.3. Follow manufacturer’s directions on cleaner.4. Do not mix cleaners.5. Avoid drips and splashes.6.
HOW TO CLEAN THE UNIT:
Soil Cleaner Method
DOOR
(Laminated Vinyl)
CABINET
(Aluminum)
Inside
and
Outside
DIRT Mild *detergent and water.
GREASE and OIL Weak, alcohol-type cleaner.
DIRT Mild *detergent and hot
FINGERPRINTS, GREASE and OIL
WATER SPOTS Mild abrasive cleaner 1. Apply with damp cloth.
*Mild detergents include soaps and non-abrasive cleaners.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
water, or mild abrasive cleaner.
Steam (no strong alkaline additive)
Chemical oven cleaner for aluminum
Mild abrasive cleaner; oily or waxy cleaner.
1. Wipe with soft, damp cloth.
2. Rinse well.
1. Wipe with soft, damp cloth.
2. Rinse well.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry
1. Rinse after steam cleaning.
2. Wipe dry. Follow oven cleaner manufacturer’s
directions. Apply with soft, clean cloth.
2. Rinse and dry.
Proof/Hot
Cabinets
FL-0604
5925 Heisley Road • Mentor, OH 44060-1833
Rev. 20 (3/10) Page 3 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 120-PH and 121-PH Series Proof/Hot Cabinets
DELIME OR DESCALE RESERVOIR PARTS AS REQUIRED
CAUTION
W ARRANTY COVERAGE MAY BE AFFECTED WITHOUT PROPER CLEANING.
TROUBLE-SHOOTING CHART:
FAILURE POSSIBLE CAUSE
1. Yellow light does NOT light. 1a. Circuit breaker/fuse to wall outlet is blown.
2. Red light does NOT light. 2a. Thermostat turned “OFF”.
3. Unit does not get hot.
TO PREVENT DAMAGING BUILD-UP.
1b. Cord is unplugged from wall outlet or cabinet. 1c. Switch is “OFF”.
2b. Thermostat set too low (light comes on when
heater is on).
3a. Thermostat set too low or is “OFF”. 3b. Water in pan my be low. 3c. Switch is “OFF”.
4. Unit gets too hot or won’t shut off. 4a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
5. Humidity is low 5a. Water in pan may be low 5b. Thermostat set too low
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
Instructions for replacing parts are included with the replacement parts kits.
REPLACEMENT PARTS:
Description 120 Volt 240 Volt
Proof/Hot Unit ...........................................PHU-18-747-18 .................... PHU-18-747-19
Water Pan w/Heater ...................................0756-014 ...............................0756-015
Water Pan Cover ........................................1245-001 ...............................1245-001
Heater (Water Pan) 1000W ........................0811-005-K
Heater (Water Pan) 900W .........................................................................0811-015K
Heater (Tunnel)..........................................0811-075 ...............................0811-078
Latch, Door ................................................1136-K .................................. 1136-K
Power Cord Kit ..........................................0810-093 ...............................0810-039
Power Light (Yellow) ................................0766-048 ............................... 0766-045
Power Light (Red) .....................................0766-047 ...............................0766-046
Relay ..........................................................0857-097 ...............................0857-098
Switch Kit ..................................................0808-082 ...............................0808-010
Strain Relief Collar ....................................5459-004-03 ..........................5459-004-1
Terminal Block ..........................................0978-007-K ........................... 0978-007-K
Thermostat Kit ...........................................0848-062-K ........................... 0848-062-K
Thermometer Kit .......................................5238-018-K ........................... 5238-018-K
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Proof/Hot
Cabinets
FL-0604
Rev. 20 (3/10) Page 4 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 120-PH and 121-PH Series Proof/Hot Cabinets
TH2
PL2 PL1
R
23
12
26
12
17
A
24
16
6
H3
21
H1
6
2
H4
1
2
5925 Heisley Road • Mentor, OH 44060-1833
WIRING DIAGRAMS
TH1
SW.
23
1
10
29
26
12
5
7
27
TB
28
29
1
PL3 PL4
A
9
R
16
10
27
10
5
5
LEGEND
H4 HEATER-TUNNEL H1 HEATERS-AIR H3 HEATER-RESERVOIR PL1 PILOT LIGHT, RESERVOIR-AMBER PL2 PILOT LIGHT, RESERVOIR-RED PL3 PILOT LIGHT, AIR-AMBER PL4 PILOT LIGHT-AIR-RED SW SWITCH TB TERMINAL BLOCK TH1 THERMOSTAT-AIR TH2 THERMOSTAT-RESERVOIR 5-20P FLANGED INLET 120V, 20A
SLEEVING WIRENUT
ELECTRICAL SPECS.
MODEL #0747-018
110/120V, 2025 W,
1Ph, 50/60Hz, AC Service
W
G
5-20P
LEGEND
H4 HEATER-TUNNEL H1 HEATERS-AIR H3 HEATER-RESERVOIR PL1 PILOT LIGHT, RESERVOIR-AMBER PL2 PILOT LIGHT, RESERVOIR-RED PL3 PILOT LIGHT, AIR-AMBER PL4 PILOT LIGHT-AIR-RED SW SWITCH TB TERMINAL BLOCK TH1 THERMOSTAT-AIR TH2 THERMOSTAT-RESERVOIR 5-20P FLANGED INLET 120V, 20A
SLEEVING WIRENUT
ELECTRICAL SPECS.
MODEL #0747-019
220/240V, 1925 W,
1Ph, 50/60Hz, AC Service
23 12
TH2
20
PL2 PL1
R
24
26
17
6
20
SW.
2
19
20
16
26
H3
21
H1
H4
2
6-15P
2
23
1
10
29
12
5
7
27
1
G
28
29
1
TB
PL3 PL4
AA
2
R
16
10
27
TH1
10
5
5
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Loading...