Crenova 6016A Operating Manual

Operating Manual of Crenova 6016A Clamp Digital Multimeter
I. Overview
Crenova 6016A is a battery-driven 3 1/2 digital clamp meter for automatic range conversion which is characterized by stable performance and high reliability. This meter applies 16mm word height LCD with distinct readings, and features maximum hold, data hold and automatic on-off function.
This clamp meter can be used for measuring parameters such as DC voltage, AC voltage, resistance, diode and on-off test. The complete meter is cored by dual integral A/D conversion of large scale integrated circuit and features automatic range conversion function. It is a high-performance meter well received by lab, factory, radio amateur and family.
Warning: before using the clamp meter, please read through “Safety Precautions”.
We have already sent an online manual to you, please check your email.You can reply us in the email about any question. Thank you.
II. Open-case inspection
Open the packing case and check if the following items are missing or damaged.
One 6016A+digital clamp meter One leather box One certificate of inspection One copy of operating manual One pair of test leads Two 1.5V AAA batteries
III. Safety precautions Please note warning sign and warning words. It means cases or behavior which may pose danger to user or cause damage to the clamp meter or device under test.
This meter is strictly in line with GB4793 Safety Requirements on Electronic Measuring Instrument, IEC61010 and IEC1010-2-032 safety standard. It complies with safety standard for double insulation, over-voltage CAT III 300V and pollution class 2. Before use, please read through the operating manual.
1.When voltage above 30V, AC power line with inductive load is measured. When AC power line during electric fluctuation is measured, please be cautious of electric shock.
2.Before measuring, check if the measurement function switch is at correct position. Check test leads for
reliable contact, correct connection and good insulation to avoid electric shock.
3.Clamp meter only meets safety standard when used with its supporting test leads. When test lead line is
damaged, please replace with lead line of the same model or the same electric specification.
4.Do not replace the battery inside with other non-confirmed or non-recognized one. Use battery of the same model or electric specification only. Before replacing, the test lead must be away from the measurement point and make sure the input end has no signal.
5.When do electrical measurements, human body should have no direct contact with earth. Do not touch
any metal terminal, output terminal or lead clamp which have exposed ground potential.
6.Do not store or use it in high temperature, high humidity, inflammable, explosive environment or high
magnetic field.
7.Measure limit voltage which is beyond allowed range will cause damage to the clamp meter and injury
to operator. Allowable limit voltage is indicated on the surface of clamp meter. Do not measure input signal which beyond this standard so as to prevent electric shock or damage to the clamp meter.
8.Do not apply 600V above voltage between clamp meter terminal and earth so as to prevent electric
shock or damage to the clamp meter.
9.Do not attempt to calibrate or repair the clamp meter. When necessary, it should be done by personnel
with specialized training or qualification.
10.When measuring, function/range selection switch must be at correct range gear. When shifting
function/range selection switch, please disconnect the line of test lead from the object under test, and
make sure the input end has no signal input. Do not shift function/range selection switch during
measurement.
11.When LCD shows , please replace battery in time to make sure measurement accuracy.
12.Do not change clamp meter circuit without permission, so as to prevent damage to clamp meter or
safety risk.
IV. Safety symbols
Warning
DC
High voltage
AC Earth
AC/DC
Double insulation
European Union directive conformity
Battery under-volta ge
Fuse
V. Surface structure
1.Clamp sensor/Jaw;
2.Instrument meter;
3.Trigger;
4.Function/range switch; for selecting measurement functions and ranges.
5.(SELECT) shift key of diode/buzzer;
6.(RANGE) shift key of auto/manual;
7.(HOLD) data hold key;
8.(MAX) maximum hold key;
9.LCD display screen;
10.COM input hole: negative input end, insert black test lead in;
11.VΩ input hole: measure voltage,
resistance, diode and positive input end of on-off test, insert red test lead in;
VI. Display symbols
1.Low battery indicator;
2.Negative polarity indicator;
3.AC signal measurement indicator;
4.DC signal measurement indicator;
5.Automatic range indicator;
6.Diode measurement indicator;
7.Continuous inspection indicator;
8.Maximum measurement indicator;
9.Data hold indicator ;
10.Relative value measurement indicator;
11.Triode measurement indicator;
12.Degree centigrade measurement indicator;
13.Fahrenheit measurement indicator;
14.Resistance measurement unit (Ω ohm, kΩ kiloohm, MΩ megohm);
15.Current measurement unit (A ampere, mA milliampere, uA microampere);
16.Voltage measurement unit (V volt, mV millivolt, uV microvolt).
Note: item 10, 11, 12 and 13 are not available for 6016A+.
VII. Key functions and auto power-off
SELECTPress the button to select indicated measurement function when there are two or more
measurement functions on the same gear. It shifts between diode and buzzer measurements.
RANGE: The meter is in automatic range when starts up, press the “RANGE” button to activate
manual range mode. In the mode of manual range, each press lets the meter skip to the previous shift. When it goes to the highest shift, it goes back to the lowest shift automatically. The procedure repeats again in the same order. Press the “RANGE” button over 2 seconds, it will exit from manual range measurement mode and shift to automatic range measurement mode.
HOLD:Press the “HOLD” button, the measurement value showed on the screen will be locked.
Press this button again, it will unlock and enter the state of regular measurement.
MAX Press the “MAX” button, the display screen will show maximum value of the whole
measurement process automatically. Press this button again, it will cancel maximum reading hold status and enter the state of regular measurement.
Auto power-off function: In measurement process, if function button or function/range selection
switch has no operation within 15 minutes, the meter will power-off automatically. In the mode of auto power-off, press function button (valid operation) or rotate function/range selection switch, the meter will power on automaticallyand enter the measurement mode. Press and hold HOLDbutton when start up, the auto power-off function will be canceled.
Note: Auto power offrefers to a dormant state. In dormant mode, small current (about 5μA)
will be consumed. If it will not be used for a long time, please cut off power and take the battery out.
Buzzer: Press any one of functional buttons at any gear, if the button is effective, the buzzer will
beep. (2/20A buzzer will make no sound , and keep silence if the operation is invalid.) About 1
1
2
3
4
5
6
7
8
9
10
11
12
13 14
15
16