Eco-Response Radiator Models: ER300, ER400 and ER500
Installation Instructions
86576 Issue 1
Dimensions (including clearances diagram)
(millimetres)
ER300 1.3kW / 0.28kW
ER400 1.95kW / 0.34kW
ER500 2.6kW / 0.39kW
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
NOTE ALSO THE INFORMATION GIVEN ON THE APPLIANCE
These instructions should not be left with the user, as this would invite the dismantling and servicing by unqualified persons.
There is a separate instruction leaflet which should be left with the user explaining how the radiator should be operated.
IMPORTANT SAFETY ADVICE
WARNING - This radiator is VERY HEAVY. In order to maintain st ability and to ensure it s future safety in use, it is essential
that the radiator is FIXED SOUNDLY TO A WALL and that the feet are mounted on a FIRM, LEVEL SURF ACE. Care should be taken to avoid irregular surfaces, such as may result from tiled surrounds partially protruding under the radiator. It is important that the following instructions are strictly followed.
WARNING – It is important that the fixing device chosen is appropriate to the wall material to which the radiator is being fixed. Some modern internal building materials are very low density block and require specialised fixing devices to provide a safe, secure installation.
WARNING – If during any reassembly of the radiator, a part of the thermal insulation shows damage or deterioration which may impair safety, it should be replaced with an identical part.
WARNING – This radiator must not be located below a socket outlet.
Suggested Wall Fittings (see page 7 for further information)
Solid brick/block: No. 10 Rawlplug fibre inserts (provided). 5.5mm drill bit. Drill 8mm deeper than rawlplug length.
Plasterboard: If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 intersets.
For other wall types seek specialist advice.
DO NOT COVER OR OBSTRUCT the surfaces of the appliance.
DO NOT POSITION under windows where curtains may contact the radiator (see minimum clearances above).
DO NOT PLACE OBJECTS in contact with the radiator.
Wall, Curtains or Furniture
Curtains
Shelf or Overhang
Furniture or other obstruction
110mm
150mm min.
250mm min.
75mm min.
75mm min.
A
B
C
TO ENSURE THIS APPLIANCE IS OPERA TING CORRECTL Y , IT IS ESSENTIAL TO PERFORM THE CHECK PROCEDURE DET AILED ON
THE BACK PAGE OF THIS INSTRUCTION. THIS MUST BE COMPLETED BEFORE NORMAL OPERATION COMMENCES.
Model Height A Width B Depth C
ER300 712mm 600mm 130mm +10mm ER400 712mm 830mm 130mm +10mm ER500 712mm 1050mm 130mm +10mm
- 2 -
Energy Retention Cells
Energy retention cells are supplied separately to the radiator in packs of two. The reference number is 75-779999.
ER300 8 Cells (4 Packs)
ER400 12 Cells (6 Packs)
ER500 16 Cells (8 Packs)
Electrical Connection
WARNING – THIS APPLIANCE MUST BE EARTHED
The installation of this appliance should be carried out by a competent electrician in accordance with I.E.E. Regulations for Electrical Equipment.
The radiator is fitted with two flexible cables for connection to the fixed wiring of the premises through suitable switched connection boxes positioned adjacent to the radiator.
Each supply circuit to the radiator must incorporate a means for disconnection in all poles in accordance with the wiring rules. This radiator is not suitable for connection to a 30A ring circuit.
IMPORTANT
The wires in the mains leads are coloured in accordance with the following code: GREEN & YELLOW: EARTH BLUE: NEUTRAL BROWN: LIVE BLACK (direct acting supply only): CONTROL WIRE
- 3 -
Circuit Diagram
- 4 -
3
INST ALLA TION OF THE RADIA TOR
Turn the carton upside down and open the carton from
the bottom. Remove the feet from the polystyrene corner supports, and the plinth and accessories bag from the polystyrene centre support.
2
Remove the clip containing the probe from the bottom
of the radiator. See Picture below .
1
(Do not discard the clip or remove probe from clip).
3
Fit the feet to the radiator by engaging the flanges on
the top of the foot with the slots in the base of the radiator 1. Push the foot towards the back of the radiator until it is fully engaged 2. Clip the probe onto the open side of the adjacent foot.
3
ASSEMBLY
2
2
4
The radiator is packed with the direct acting mains cable
clipped to the underside of the radiator ensuring it is secure during transit. The off peak mains cable will be secured with cable ties. Prior to installing the radiator , unclip the direct acting mains cable (do not remove or discard these clips).
NOTE: If the off peak mains connection is required to be made on the right hand side of the radiator, the pre-wired cable must be passed behind the feet and secured using the clips on the base of the radiator. For ease of access this should be done while the radiator is still upside down in the carton. Similarly when the direct acting mains cable is ready to be connected (See Section 23), if the connection is required to be made on the left hand side of the radiator the cable must be routed behind the feet. DO NOT clip the direct acting mains cable at this stage (See Section 23). The cable clips are already fitted at the factory to allow both mains cables to be attached, if required.
1
3
3