IMPORTANT WARNINGS!
DO NOT SWITCH THE APPLIANCE ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
DO NOT OPERATE THE APPLIANCE IF WATER DISCHARGES FROM THE PRESSURE RELIEF
VALVE. MAINTENANCE IS REQUIRED BEFORE THE APPLIANCE CAN BE SAFELY USED.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN)
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
DO NOT PLAY WITH THE APPLIANCE.
1. Ensure the electricity and water are turned on to the unit.
2. Press the start / stop button “B”.
This will turn the shower on, the water will flow and the
neon indicator light will illuminate. It is recommended that
you do not wholly enter the water flow during this period.
3. Knob “A” controls the power selection.
Select “High / ”, “Medium / ” or “Cold / ”
The “small bar” indicates knob setting.
4. If the water is not at your desired showering
temperature, turn knob “C” a small amount until you
reach the desired showering temperature.
Turn clockwise for cooler.
Turn anti-clockwise for warmer.
5. When you have finished showering, press the start / stop button “B” again.
The water will stop flowing and the neon indicator will go out.
10.5kW Models Only-Water will continue to flow for approximately 7 seconds before switching off.
6. Switch off the electricity supply at the ceiling switch or local isolator.
Notes
• Wait 20 seconds for the temperature to stabilise after each adjustment.
• The neon indicator light illuminates when the heaters are on and, if the shower has
been recently used, it may take up to 20 seconds to come on
During this time the water may go from very hot to cold before stabilising.
• The position of knob “C” will be approximately the same each time the shower is
used, varying only with incoming water temperature or pressure changes
(e.g. you will only need to change from summer to winter).
• During normal operation, if an overheated water temperature is sensed then the
heater will switch off and the neon indicator light will go out.
Water will continue to flow and cool down before the heater switches back on again.
We offer a technical advisory service on the telephone to installers and
other customers with problems in the field. RING 0870 9000 430 (UK ONLY)
(A3) Leaflet No. 567-2151-04 Revision A
HOW TO USE YOUR AQUAWAVE CONTEMPORARY SHOWER (SUMMARY)
Relates to the Contemporary Shower Range ONLY, see unique section for Heritage Range
IMPORTANT:
This booklet should be left with the user
after installation and demonstration
AQUAWAVE RANGE
(Covers White, Colour and Heritage Models)
ELECTRIC SHOWER
Installation and User Guide

INTRODUCTION
If you experience any difficulty with the installation or operation of your new
shower, then please refer to the “What to do if things go wrong” section in this
manual before contacting us.
Section
Introduction . . . . . . . . . . . . . . . . . . . . . .
Important Safety Information . . . . . . . . . .
How to install your Aquawave Shower . . . .
Cold Water Inlet Pipe Configuration. . . . . . .
Assembly of Accessories . . . . . . . . . . . . . .
How to maintain your Aquawave Shower . .
How to use your Aquawave
Contemporary Shower (Detailed) . . . . . . . .
How to use your Aquawave
Heritage Shower (Detailed) . . . . . . . . . . . .
What to do if things go wrong (1)
Self Help . . . . . . . . . . . . . . . . . . . . . . . . .
Page
2
2
3
5
8
8
9
10
11
Section
Additional Accessories and Common Parts . .
What to do if things go wrong (2)
Professional Service . . . . . . . . . . . . . . . . .
Creda After Sales Service . . . . . . . . . . . . .
How your Aquawave Shower Works . . . . . .
Guarantee and Contact Details . . . . . . . . . .
How to use your Aquawave
Heritage Shower (Summary) . . . . . . . . . . .
How to use your Aquawave
Contemporary Shower (Summary) . . . . . . .
Page
11
12
12
13
14
15
16
Thank you for purchasing a quality Creda Aquawave Shower manufactured in England.
To enjoy your new shower at its best, please take time to read this manual thoroughly to
familiarise yourself with all instructions, BEFORE beginning installation.
Having done so, keep this manual handy for future reference.
Your shower is designed to stabilise temperature changes caused by water pressure fluctuations.
These can result from toilets being flushed or taps being turned on and off.
When this happens your showering temperature will be held within a controlled band, provided that
the minimum pressure required by the shower is maintained (see “Effect of Other Water Devices”).
1. Your shower has been designed for convenience, economy and safety of use, provided that it is
installed, used and maintained in good working order and in accordance with our instructions and
recommendations.
2. All wiring and installation must be supervised by a suitably qualified person.
3. THIS APPLIANCE MUST BE EARTHED.
4. The installation must be in accordance with the current edition of BS.7671 (the “IEE Wiring
Regulations”) and “Part P” of the “Building Regulations” in force at the time of installation.
Installations outside of England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed electrical wiring of the mains
supply with its own dedicated supply.
5. This appliance must NOT be fitted where it may be subjected to freezing conditions.
6. DO NOT switch the appliance on if you suspect it of being frozen.
Wait until you are sure it has thawed out.
7. DO NOT fit any sort of tap or control on the appliance outlet. The appliance is designed to have
an open outlet and should only be used with “Creda” recommended fittings.
8. Take care to avoid restricting the outlet of the pressure relief device. If water is discharged from
the pressure relief device, maintenance will be required before the appliance can be safely used.
9. Isolate the mains electrical and water supply before removing the front cover of the appliance.
CONTENTS
IMPORTANT SAFETY INFORMATION
15
IMPORTANT WARNINGS!
DO NOT SWITCH THE APPLIANCE ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
DO NOT OPERATE THE APPLIANCE IF WATER DISCHARGES FROM THE PRESSURE RELIEF
VALVE. MAINTENANCE IS REQUIRED BEFORE THE APPLIANCE CAN BE SAFELY USED.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN)
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
DO NOT PLAY WITH THE APPLIANCE.
1. Ensure the electricity and water are turned on to the unit.
2. Press the start / stop button “B”.
This will turn the shower on, the water will flow and the
neon indicator light will illuminate. It is recommended that
you do not wholly enter the water flow during this period.
3. Knob “A” controls the power selection.
Select “High”, “Med (medium)” or “Cold”
4. If the water is not at your desired showering
temperature, turn knob “C” a small amount until you
reach the desired showering temperature.
Turn clockwise for cooler.
Turn anti-clockwise for warmer.
5. When you have finished showering, press the start / stop button “B” again.
The water will stop flowing and the neon indicator will go out.
10.5kW Models Only-Water will continue to flow for approximately 7 seconds before switching off.
6. Switch off the electricity supply at the ceiling switch or local isolator.
Notes
• Wait 20 seconds for the temperature to stabilise after each adjustment.
• The neon indicator light illuminates when the heaters are on and, if the shower has
been recently used, can take up to 20 seconds to come on
During this time the water may go from very hot to cold before stabilising.
• The position of knob “C” will be approximately the same each time the shower is
used, varying only with incoming water temperature or pressure changes
(e.g. you will only need to change from summer to winter).
• During normal operation, if an overheated water temperature is sensed then the
heater will switch off and the neon indicator light will go out.
The water will continue to flow and cool down before the heater switches back on
again.
HOW TO USE YOUR AQUAWAVE HERITAGE SHOWER (SUMMARY)
Relates to the Heritage Shower Range ONLY, see unique section for Contemporary Range

Full details of terms and conditions are available on request from:-
APPLIED ENERGY PRODUCTS LIMITED
MORLEY WAY, PETERBOROUGH PE2 9JJ
TEL: +44 (0) 1733 456789
FAX: +44 (0) 1733 310606
Website: www.creda-showers.co.uk
GUARANTEE AND CONTACT DETAILS
3
WARNING: ALL WIRING AND INSTALLATION MUST BE
SUPERVISED BY A SUITABLY QUALIFIED PERSON.
WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE
SUBJECTED TO FREEZING CONDITIONS
We recommend that the installation is done in the following sequence.
a. Fixing the shower to the wall b. Plumbing c. Electrical connections
a. FIXING THE SHOWER TO THE WALL
1. Position the riser rail at a convenient height for majority of users as
detailed in Diagram 1 and mark its position.
2. Position the heater so that the top of the unit is horizontal and level
with, or a maximum of 0.6 metres (2ft) below the top of the
riser rail. Choose a flat piece of wall to avoid the possibility of
distorting the backplate, as this may make the front cover a poor fit.
3. Adjust the position to get the most convenient arrangement taking
the following into account.
• The heater must not be mounted in the direct spray from the handset.
• The handset must not be able to come into contact with used water in the cubicle, bath or
basin. If it can, then a vacuum breaker must be fitted (available from us if required).
4. Fix the riser rail with screws provided
The fixing holes at the base of the brackets will be disclosed by removing the plastic fronts.
Aquawave Contemporary Models (See Diagrams 5a/b and instructions supplied with accessories).
Aquawave Heritage Models (see Diagram 5c).
5. If you have not yet done so, remove the front cover assembly by undoing the retaining screws at
the top and bottom of the unit and lifting the cover off.
6.
Your shower unit not only accepts services from the top, bottom or rear.
It also accepts services from the left or right hand side of the unit.
the electrical cable into the unit.
If top entry is chosen, cut away the walls in the backplate as shown in Diagram 2a.
If bottom entry is chosen, cut away
the walls in the detachable bottom
section as shown in Diagram 2b.
The detachable bottom section is
secured to the backplate by 2 screws.
7. Decide the position of entry of the
cold water pipe into the unit.
If top entry is chosen,
cut away the backplate as shown in
If bottom entry is chosen, cut away the
walls in the detachable bottom section
as shown in Diagram 2b.
If rear, please read the section on plumbing. To aid installation, you may find it convenient to
move the flexible pressure relief valve outlet assembly by removing the two securing screws.
If you do, please ensure that they are fully tightened on re-assembly (see Diagram 2b).
HOW TO INSTALL YOUR AQUAWAVE SHOWER