12
IMPORTANT WARNINGS!
DO NOT SWITCH THE APPLIANCE ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
DO NOT OPERATE THE APPLIANCE IF WATER DISCHARGES FROM THE PRESSURE RELIEF
VALVE. MAINTENANCE IS REQUIRED BEFORE THE APPLIANCE CAN BE SAFELY USED.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN AND
THE INFIRM) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
DO NOT PLAY WITH THE APPLIANCE.
1. Ensure the electricity and water are turned on to the unit.
2.
Your shower can be turned on by pressing either
Button “A”, Button “B” or Button “C”
Button “A” (III) - Starts shower on “High” power.
Button “B” (II) - Starts shower on “Medium” power.
Button “C” (I) - Starts shower on “Cold”.
Press Button “A”, “B” or “C”.
Water will flow and the LED indicator above your choice
will illuminate. It is recommended that you do not wholly
enter the water flow during this period.
3. If the water is not at your desired showering temperature,
turn knob “E” a small amount until you
reach the desired showering temperature.
Turn clockwise for cooler or Turn anti-clockwise for warmer.
4. When you have finished showering, press Button “D” ( ) only, the LED light above will flash
Water will continue to flow for up to 7 seconds before switching off.
5. Switch off the electricity supply at the ceiling switch or local isolator.
Notes
• Wait 20 seconds for the temperature to stabilise after each adjustment.
• The LED indicator light illuminates when the heaters are on and, if the shower has
been recently used, can take up to 20 seconds to come on
During this time the water may go from very hot to cold before stabilising.
• The position of knob “E” will be approximately the same each time the shower is
used, varying only with incoming water temperature or pressure changes
(e.g. you will only need to change from summer to winter).
• During normal operation, if an overheated water temperature is sensed then the
heater will switch off and the LED indicator light will go out.
Water will continue to flow and cool down before the heater switches back on again.
We offer a technical advisory service on the telephone to installers and
other customers with problems in the field. RING 0870 9000 430 (UK ONLY)
(A3) Leaflet No. 567-2189-01 Revision A
HOW TO USE YOUR JETSPA SHOWER (SUMMARY)
IMPORTANT:
This booklet should be left with the user
after installation and demonstration
JETSPA CONTEMPORARY
ELECTRIC SHOWER
Installation and User Guide

INTRODUCTION
If you experience any difficulty with the installation or operation of your new
shower, then please refer to the “What to do if things go wrong” section in this
manual before contacting us.
Section
Introduction . . . . . . . . . . . . . . . . . . . . . .
Important Safety Information . . . . . . . . . .
How to install your Jet Spa Shower . . . . . .
Cold Water Inlet Pipe Configuration. . . . . . .
Assembly of Accessories . . . . . . . . . . . . . .
How to maintain your Jet Spa Shower . . . .
Additional Accessories and Common Parts . .
How to use your Jet Spa Shower (Detailed)
Page
2
2
3
5
7
7
7
8
Section
What to do if things go wrong (1)
Self Help . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (2)
Professional Service . . . . . . . . . . . . . . . . .
How your Jet Spa Shower Works . . . . . . . .
Creda After Sales Service . . . . . . . . . . . . .
Guarantee and Contact Details . . . . . . . . . .
How to use your Jet Spa Shower
Page
9
9
10
11
11
12
Thank you for purchasing a quality Creda Jet Spa Shower manufactured in England.
To enjoy your new shower at its best, please take time to read this manual thoroughly to
familiarise yourself with all instructions, BEFORE beginning installation.
Having done so, keep this manual handy for future reference.
Your shower is designed to stabilise temperature changes caused
by water pressure fluctuations.
These can result from toilets being flushed or taps being turned on and off.
When this happens your showering temperature will be held within a controlled band, provided that
the minimum pressure required by the shower is maintained (see “Effect of Other Water Devices”).
1. Your shower has been designed for convenience, economy and safety of use, provided that it is
installed, used and maintained in good working order and in accordance with our instructions and
recommendations.
2. All wiring and installation must be supervised by a suitably qualified person.
3. THIS APPLIANCE MUST BE EARTHED.
4. The installation must be in accordance with the current edition of BS.7671 (the “IEE Wiring
Regulations”) and “Part P” of the “Building Regulations” in force at the time of installation.
Installations outside of England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed electrical wiring of the mains
supply with its own dedicated supply.
5. This appliance must NOT be fitted where it may be subjected to freezing conditions.
6. DO NOT switch the appliance on if you suspect it of being frozen.
Wait until you are sure it has thawed out.
7. DO NOT fit any sort of tap or control on the appliance outlet. The appliance is designed to have
an open outlet and should only be used with “Creda” recommended fittings.
8. Take care to avoid restricting the outlet of the pressure relief device. If water is discharged from
the pressure relief device, maintenance will be required before the appliance can be safely used.
9. Isolate the mains electrical and water supply before removing the front cover of the appliance.
CONTENTS
IMPORTANT SAFETY INFORMATION
11
GUARANTEE AND CONTACT DETAILS
CREDA AFTER SALES SERVICE
We offer a technical advisory service on the telephone to installers and other customers with
problems in the field. RING 0870 9000 430 (UK ONLY)
Remember to quote the exact type of shower, as written on the shower front and on is leaflet.
The model and serial number are located on the bottom face of the shower.
Make a note of those numbers here, and be sure to quote them if you call for advice.
Model Number: 53-67_ _ _ _ _ _ _ _ _ _ _ / Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _ _
Note: You may be charged for a service call if you do not have the serial number.
APPLIED ENERGY PRODUCTS LIMITED, MORLEY WAY, PETERBOROUGH PE2 9JJ
TEL: +44 (0) 1733 456789 / FAX: +44 (0) 1733 310606