Extremely flammable aerosol. Contains gas under pressure; may explode if heated. May be fatal if
1. Identification
Power Lube® High Performance Lubricant w/PTFEProduct identifier
Other means of identification
Product Code
Recommended use
Recommended restrictions
Manufacturer/Importer/Supplier/Distributor information
Manufactured or sold by:
Company name
Address
Telephone
General Information
Technical Assistance
Customer Service
24-Hour Emergency
(CHEMTREC)
Website
No. 03045 (Item# 1003304)
Multi-purpose lubricant
None known.
CRC Industries, Inc.
885 Louis Dr.
Warminster, PA 18974 US
215-674-4300
800-521-3168
800-272-4620
800-424-9300 (US)
703-527-3887 (International)
2. Hazard(s) identification
Physical hazards
Health hazards
Environmental hazards
OSHA defined hazards
Label elements
Signal word
Hazard statement
Precautionary statement
Prevention
Category 1Flammable aerosols
Liquefied gasGases under pressure
Category 2ASerious eye damage/eye irritation
Category 2Reproductive toxicity (fertility)
Category 1Aspiration hazard
Category 3Hazardous to the aquatic environment, acute
hazard
Category 3Hazardous to the aquatic environment,
long-term hazard
Not classified.
Danger
swallowed and enters airways. Causes serious eye irritation. Suspected of damaging fertility.
Harmful to aquatic life. Harmful to aquatic life with long lasting effects.
Obtain special instructions before use. Do not handle until all safety precautions have been read
and understood. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Do not
spray on an open flame or other ignition source. Pressurized container: Do not pierce or burn,
even after use. Do not apply while equipment is energized. Extinguish all flames, pilot lights and
heaters. Vapors will accumulate readily and may ignite. Use only with adequate ventilation;
maintain ventilation during use and until all vapors are gone. Open doors and windows or use
other means to ensure a fresh air supply during use and while product is drying. If you experience
any symptoms listed on this label, increase ventilation or leave the area. Wash thoroughly after
handling. Wear protective gloves/protective clothing/eye protection/face protection. Avoid release
to the environment.
Material name: Power Lube® High Performance Lubricant w/PTFE
If swallowed: Immediately call a poison center/doctor. Do NOT induce vomiting. If in eyes: Rinse
cautiously with water for several minutes. Remove contact lenses, if present and easy to do.
Continue rinsing. If eye irritation persists: Get medical advice/attention. If exposed or concerned:
Get medical advice/attention.
Store in a well-ventilated place. Store locked up. Protect from sunlight. Do not expose to
temperatures exceeding 50°C/122°F. Exposure to high temperature may cause can to burst.
Dispose of contents/container in accordance with local/regional/national regulations.
Static accumulating flammable liquid can become electrostatically charged even in bonded and
grounded equipment. Sparks may ignite liquid and vapor. May cause flash fire or explosion.
When exposed to extreme heat or hot surfaces, vapors may decompose to harmful or fatal
corrosive gases such as hydrogen fluoride.
3. Composition/information on ingredients
Mixtures
64742-47-8distillates (petroleum), hydrotreated
light
68476-86-8liquefied petroleum gas10 - 20
64742-70-7paraffin oils (petroleum), catalytic
dewaxed heavy
119-36-8methyl salicylate3 - 5
64742-71-8paraffin oils (petroleum), catalytic
dewaxed light
107-83-52-methylpentane1 - 3
34590-94-8dipropylene glycol monomethyl
ether
61788-89-4fatty acids, C18-unsatd., dimers1 - 3
64742-49-0naphtha (petroleum), hydrotreated
light
8009-03-8petrolatum1 - 3
68608-26-4sodium petroleum sulfonate1 - 3
110-54-3n-hexane< 0.3
94270-86-7benzotriazole-methanamine< 0.2
Specific chemical identity and/or percentage of composition has been withheld as a trade secret.
4. First-aid measures
Inhalation
Skin contact
Eye contact
Ingestion
Most important
symptoms/effects, acute and
delayed
Indication of immediate
medical attention and special
treatment needed
General information
Move to fresh air. Call a physician if symptoms develop or persist.
Wash off with soap and water. Get medical attention if irritation develops and persists.
Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if
present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
Call a physician or poison control center immediately. Rinse mouth. Do not induce vomiting. If
vomiting occurs, keep head low so that stomach content doesn't get into the lungs.
Aspiration may cause pulmonary edema and pneumonitis. Headache. Nausea, vomiting. Diarrhea.
Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred
vision.
Provide general supportive measures and treat symptomatically. Keep victim under observation.
Symptoms may be delayed.
IF exposed or concerned: Get medical advice/attention. Ensure that medical personnel are aware
of the material(s) involved, and take precautions to protect themselves. Show this safety data
sheet to the doctor in attendance.
30 - 40
10 - 20
3 - 5
1 - 3
1 - 3
5. Fire-fighting measures
Suitable extinguishing media
Unsuitable extinguishing
media
Material name: Power Lube® High Performance Lubricant w/PTFE
Water fog. Alcohol resistant foam. Dry chemicals. Carbon dioxide (CO2). Dry chemical powder,
carbon dioxide, sand or earth may be used for small fires only.
Do not use water jet as an extinguisher, as this will spread the fire.
SDS US
2 / 13
Specific hazards arising from
the chemical
Special protective equipment
and precautions for firefighters
Fire fighting
equipment/instructions
General fire hazards
Contents under pressure. Pressurized container may rupture when exposed to heat or flame. This
product is a poor conductor of electricity and can become electrostatically charged. If sufficient
charge is accumulated, ignition of flammable mixtures can occur. Static electricity accumulation
may be significantly increased by the presence of small quantities of water or other contaminants.
Material will float and may ignite on surface of water. During fire, gases hazardous to health may
be formed. When exposed to extreme heat or hot surfaces, vapors may decompose to harmful or
fatal corrosive gases such as hydrogen fluoride.
Firefighters must use standard protective equipment including flame retardant coat, helmet with
face shield, gloves, rubber boots, and in enclosed spaces, SCBA.
In case of fire: Stop leak if safe to do so. Move containers from fire area if you can do so without
risk. Cool containers exposed to heat with water spray and remove container, if no risk is involved.
Containers should be cooled with water to prevent vapor pressure build up.
Extremely flammable aerosol. Contents under pressure. Pressurized container may rupture when
exposed to heat or flame.
6. Accidental release measures
Personal precautions,
protective equipment and
emergency procedures
Methods and materials for
containment and cleaning up
Environmental precautions
Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Remove all
possible sources of ignition in the surrounding area. Keep out of low areas. Many gases are
heavier than air and will spread along ground and collect in low or confined areas (sewers,
basements, tanks). Wear appropriate protective equipment and clothing during clean-up.
Emergency personnel need self-contained breathing equipment. Do not touch damaged
containers or spilled material unless wearing appropriate protective clothing. Ventilate closed
spaces before entering them. Use appropriate containment to avoid environmental contamination.
Local authorities should be advised if significant spillages cannot be contained. For personal
protection, see section 8 of the SDS.
Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Keep
combustibles (wood, paper, oil, etc.) away from spilled material. Prevent product from entering
drains. Stop the flow of material, if this is without risk. Wipe up with absorbent material (e.g. cloth,
fleece). Clean surface thoroughly to remove residual contamination. For waste disposal, see
section 13 of the SDS.
Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all
environmental releases. Prevent further leakage or spillage if safe to do so. Avoid discharge into
drains, water courses or onto the ground. Use appropriate containment to avoid environmental
contamination.
7. Handling and storage
Precautions for safe handling
Conditions for safe storage,
including any incompatibilities
Obtain special instructions before use. Do not handle until all safety precautions have been read
and understood. Minimize fire risks from flammable and combustible materials (including
combustible dust and static accumulating liquids) or dangerous reactions with incompatible
materials. Pressurized container: Do not pierce or burn, even after use. Do not use if spray button
is missing or defective. Do not spray on a naked flame or any other incandescent material. Do not
smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind,
or expose containers to heat, flame, sparks, or other sources of ignition. Use caution around
energized equipment. The metal container will conduct electricity if it contacts a live source. This
may result in injury to the user from electrical shock and/or flash fire. Avoid contact with eyes.
Avoid prolonged or repeated contact with skin. Avoid prolonged exposure. Pregnant or
breastfeeding women must not handle this product. Should be handled in closed systems, if
possible. Use only in well-ventilated areas. Wear appropriate personal protective equipment.
Wash hands thoroughly after handling. Avoid release to the environment. Observe good industrial
hygiene practices. For product usage instructions, see the product label.
Level 3 Aerosol.
Pressurized container. Protect from sunlight and do not expose to temperatures exceeding
50°C/122 °F. Do not puncture, incinerate or crush. Do not handle or store near an open flame,
heat or other sources of ignition. This material can accumulate static charge which may cause
spark and become an ignition source. Avoid spark promoters. These alone may be insufficient to
remove static electricity. Store in a well-ventilated place. Stored containers should be periodically
checked for general condition and leakage. Store away from incompatible materials (see Section
10 of the SDS).
8. Exposure controls/personal protection
Occupational exposure limits
The following constituents are the only constituents of the product which have a PEL, TLV or other recommended exposure limit.
At this time, the other constituents have no known exposure limits.
Material name: Power Lube® High Performance Lubricant w/PTFE