Crathco 190 Installation Manual

Page 1
INSTALLATION INSTRUCTIONS FOR
CONCEALED CLOSET AND URINAL FLUSHOMETERS
Concealed Closet Flushometer — 1-1/2” Exposed Back Spud
MODEL 140 MODEL 154
Concealed Closet Flushometer — 1-1/2” Exposed Top Spud
MODEL 142 MODEL 153
Concealed Closet Flushometer — 1-1/2” Back Spud
MODEL 143 MODEL 144 MODEL 150 MODEL 152
Concealed Urinal Flushometer — Back Spud
MODEL 190 MODEL 195
Concealed Urinal Flushometer —
Model 140
Model 195
Exposed Top Spud
MODEL 192 MODEL 197
Code No. 0816170
Rev. 3 (04/14)
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special nishes, SF faucets, PWT electronics and 30 days for PWT software) from date of rst purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN
VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
PRIOR TO INSTALLATION
Check to make certain that the “L” dimension shown on the ushometer package is correct for your application. Determine the “L” dimension for your application by using the following formula:
“L” dimension = Wall Thickness (To Nearest Whole Inch) + 2-3/4”
Prior to installing a concealed ushometer, perform the following functions as illustrated in the Rough-in Diagrams on Pages 2 and 3.
• Bore a 1-1/2” (38 mm) hole in wall for Actuator.
• Bore a 2” (51 mm) [1” (25 mm) for Model 197 only] hole in wall for piping, if required.
• Install closet or urinal xture.
• Install 1-1/2” (38 mm) drain line (NOT supplied by Sloan).
• Install water supply line. Note: Concealed valves are supplied with double handle opening to allow for installation of Control Stop on either the left or right side of the valve (refer to illustration in Step 4).
IMPORTANT:
INSTALL ALL PLUMBING IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
Sloan’s ushometers are designed to operate with 10 to 100 psi (69 to 689 kPa) of water pressure.
TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.
Consult xture manufacturer for minimum pressure
THE MINIMUM PRESSURE REQUIRED
requirements.
Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum owing pressure of 25 psi (172 kPa).
!!! IMPORTANT !!!
WITH THE EXCEPTION OF CONTROL
STOP INLET, DO NOT USE PIPE THREAD
SEALANT OR PLUMBING GREASE ON VALVE
COMPONENTS OR COUPLINGS!
TOOLS REQUIRED FOR INSTALLATION
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench
• Drill to bore 1½” (38 mm) and/or 2” (51 mm) hole(s) in wall (see rough-in)
Page 2
ROUGH-IN
MODEL 140
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
14-1/2” (368 mm)
1” I.P.S.
SUPPLY
(25 mm DN )
1-1/2” (38 mm) OPENING IN WALL
4-3/4”
(121 mm)
2” (51 mm) OPENING IN WALL
10”
(254 mm)
CENTER LINE
OF FIXTURE
MODEL 142
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
9” (229 mm)
7-1/2”
(191 mm)
5” (127 mm)
1” I.P.S.
SUPPLY
(25 mm DN )
1-1/2” (38 mm) OPENING IN WALL
4-3/4”
(121 mm)
2” (51 mm) OPENING IN WALL
10”
(254 mm)
CENTER LINE
OF FIXTURE
13” (330 mm)
4” (102 mm)
MODELS 143/144
“L” DIM. 2-3/4” (70 mm) + WALL THICKNESS
MODEL 143 - 14-1/2” (368 mm) MODEL 144 - 10-1/2” (267 mm)
MODEL 143 - 13” (330 mm)
MODEL 144 - 9” (229 mm)
MODEL 153
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
CENTER LINE
OF WASTE
FIN. WALL
4-3/4”
(121 mm)
1” I.P.S.
SUPPLY
(25 mm DN )
1-1/2” (38 mm) OPENING IN WALL
2” (51 mm) OPENING IN WALL
CENTER LINE
OF WASTE
FIN. WALL
10”
(254 mm)
FIN.
FLOOR
FIN.
FLOOR
CENTER LINE
OF FIXTURE
MODEL 152
24” (610 mm)
22-1/2” (572 mm)
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
CENTER LINE
OF WASTE
FIN. WALL
1” I.P.S.
SUPPLY
(25 mm DN )
1-1/2” (38 mm) OPENING IN WALL
2” (51 mm) OPENING IN WALL
CENTER LINE
OF WASTE
FIN. WALL
FIN.
FLOOR
4-3/4”
(121 mm)
CENTER LINE
OF FIXTURE
FIN.
FLOOR
MODEL 154
1” I.P.S.
SUPPLY
(25 mm DN )
4-3/4”
(121 mm)
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
1” I.P.S.
SUPPLY
(25 mm DN )
4-3/4”
(121 mm)
1-1/2” (38 mm) OPENING
24” (610 mm)
17-1/2”
(445 mm)
5” (127 mm)
IN WALL
2” (51 mm) OPENING IN WALL
CENTER LINE
OF WASTE
FIN. WALL
FLOOR
!!! IMPORTANT !!!
WITH THE EXCEPTION OF THE CONTROL
STOP INLET, DO NOT USE PIPE THREAD
SEALANT OR PLUMBING GREASE ON
VALVE COMPONENTS OR COUPLINGS.
CENTER LINE
OF FIXTURE
FIN.
24” (610 mm)
22-1/2” (572 mm)
4” (102 mm)
NOTE: Water Closet Valves with
“-2.4” Model
Designation Deliver 2.4 gpf (9.0 Lpf)
THIS PRODUCT CONTAINS MECHANICAL AND/OR
ELECTRICAL COMPONENTS THAT ARE SUBJECT TO
NORMAL WEAR. THESE COMPONENTS SHOULD BE
CHECKED ON A REGULAR BASIS AND REPLACED AS
NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.
2
1-1/2” (38 mm) OPENING IN WALL
2” (51 mm) OPENING IN WALL
CENTERLINE
OF WASTE
FIN. WALL
!!! IMPORTANT !!!
CENTER LINE
OF FIXTURE
FIN.
FLOOR
Page 3
ROUGH-IN (CONTINUED)
MODEL 190 NOTE: Requires 1” I.P.S. (25 mm DN) SUPPLY
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
14-1/2” (368 mm)
13” (330 mm)
1-1/2” (38 mm) OPENING IN WALL
1” I.P.S.
SUPPLY
(25 mm DN )
CENTER LINE
OF FIXTURE
4-3/4” (121 mm)
MODEL 192 NOTE: Requires 1” I.P.S. (25 mm DN) SUPPLY
(25 mm DN )
2” (51 mm) OPENING IN WALL
1” I.P.S.
SUPPLY
CENTER LINE
OF FIXTURE
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
14-1/2” (368 mm)
5” (127 mm)
1-1/2” (38 mm) OPENING IN WALL
4-3/4” (121 mm)
MODEL 195
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
13-1/2” (343 mm)
12” (305 mm)
FIN. WALL
1-1/2” (38 mm) OPENING IN WALL
(20 mm DN )
2” (51 mm) OPENING IN WALL
CENTERLINE
OF WASTE
FIN. WALL
FIN.
FLOOR
3/4” I.P.S.
SUPPLY
FIN.
FLOOR
CENTER LINE
OF FIXTURE
4-3/4” (121 mm)
MODEL 197
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
13-1/2”
(343 mm)
(178 mm)
5” (127 mm)
7”
1-1/2” (38 mm) OPENING IN WALL
CENTERLINE
FIN. WALL
1” (25 mm) OPENING IN WALL
OF WASTE
FIN. WALL
FIN.
FLOOR
3/4” I.P.S.
SUPPLY
(20 mm DN )
FLOOR
4-3/4” (121 mm)
CENTER LINE
OF FIXTURE
FIN.
1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD) AND INSTALL CONTROL STOP
For Sweat Solder applications,
A
slide Threaded Adapter onto
THREADED
ADAPTER
water supply pipe until end of pipe rests against shoulder of Adapter. Sweat solder the Adapter to water supply pipe.
WATER
SUPPLY
PIPE
NOTE
CONCEALED VALVES ARE SUPPLIED WITH DOUBLE HANDLE OPENING TO ALLOW FOR INSTALLATION OF CONTROL STOP
ON EITHER THE LEFT OR RIGHT SIDE OF THE VALVE (REFER TO
ILLUSTRATION IN STEP 4).
®
Install the Sloan Bak-Chek
B
Control Stop to the water supply line with the outlet positioned as required.
OUTLET
BAK-CHEK®
CONTROL STOP
IRON PIPE NIPPLE
OR COPPER PIPE
WITH SWEAT
SOLDER ADAPTER
3
Page 4
2 - INSTALL VACUUM BREAKER FLUSH CONNECTION
Assemble Pipe, Elbows, Couplings,
A
Nylon Slip Gaskets, Rubber Gaskets and Flanges as illustrated on back page. Hand tighten all Couplings.
3 - MOUNT ACTUATOR ASSEMBLY TO WALL
Remove Actuator Shaft End, Coupling and Mounting Nut from
A
Actuator Assembly.
Insert Shaft of Actuator Assembly through the 1-1/2” (38 mm) wall
B
opening from xture side of wall.
Install Mounting Nut, Coupling and Actuator Shaft End to Actuator
C
Assembly. Hand tighten Mounting Nut to wall. Securely tighten Actuator Shaft End to Actuator assembly.
A-31 GASKET
VACUUM
BREAKER
ACTUATOR SHAFT END
IMPORTANT: WHEN CUTTING SCORED
PIPE TO FIT, LEAVE A MINIMUM
OF 1-1/4” (32 mm) OF SCORING TO
ENSURE PROPER ENGAGEMENT WITH
COMPRESSION COUPLINGS.
FLUSH
CONNECTION
COUPLING
MOUNTING NUT
ACTUATOR ASSEMBLY
WALL (FIXTURE SIDE)
4 - INSTALL FLUSHOMETER
NOTE
For high efciency urinal ushometers (0.5, 0.25 and 0.125 gpf),
it is necessary to rst insert the ow control component into the
tailpiece assembly. See the H1015A ow control kit and separate
instructions for details on how to install.
Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece
A
into Control Stop while mounting Flushometer to Actuator Assembly. Tighten Actuator and Tailpiece Couplings by hand.
Align Flushometer directly above the Vacuum Breaker Flush
B
Connection. Assemble Vacuum Breaker Flush Connection to Flushometer. Tighten Vacuum Breaker Coupling by hand.
!!! IMPORTANT !!!
USE A SLOAN A-50 “SUPER-WRENCH™”, SLOAN A-109
PLIER WRENCH OR SMOOTH JAWED SPUD WRENCH
TO SECURE ALL COUPLINGS. THIS WILL ELIMINATE
DAMAGE TO CHROME OR SPECIAL FINISH THAT
NORMALLY OCCURS WHEN SLIP-JOINT PLIERS, PIPE
WRENCHES OR OTHER “TOOTHED” TOOLS ARE USED.
Use a wrench to tighten the following couplings in the order shown.
C
Align Flushometer Body and securely tighten rst the Tailpiece Coupling Breaker Coupling nally the Spud Coupling
Using a wrench, securely tighten Actuator Mounting Nut to wall.
D
MAXIMUM ADJUSTMENT OF THE SLOAN ADJUSTABLE TAILPIECE
IF ROUGHING-IN MEASUREMENT EXCEEDS 5-1/4” (133 MM),
(1), then the Actuator Coupling (2), then the Vacuum
(3), then all Flush Connection Couplings (4) and
(5).
NOTE
IS 1/2” (13 MM) IN OR OUT FROM THE STANDARD 4-3/4” (121 MM) (CENTERLINE OF FLUSHOMETER
TO CENTERLINE OF CONTROL STOP).
CONSULT FACTORY FOR LONGER TAILPIECE.
4
ACTUATOR ASSEMBLY COUPLING
2
4-1/4”
(108 mm)
MAX.
5-1/4”
(133 mm)
MAX.
FLUSHOMETER BODY
VACUUM BREAKER
3
COUPLING
A-31 GASKET
ADJUSTABLE TAILPIECE
TAILPIECE COUPLING
G-44 GASKET
FLUSH
4
CONNECTION COUPLINGS
SPUD COUPLING
5
1
CONTROL STOP
Page 5
5 - FLUSH OUT SUPPLY LINE AND ADJUST CONTROL STOP
A
Shut off Control Stop by turning handle CLOCKWISE. Then remove Flushometer Cover.
SLOAN FLUSHOMETERS ARE ENGINEERED FOR QUIET
OPERATION. EXCESSIVE WATER FLOW CREATES NOISE,
WHILE TOO LITTLE WATER FLOW MAY NOT SATISFY THE
NEEDS OF THE FIXTURE. PROPER ADJUSTMENT IS MADE
Lift out the inside Parts Assembly as
B
a complete unit. Reinstall Flushometer Cover and tighten with wrench. Open Control Stop. Turn on water supply to ush line of any debris or sediment.
WHEN THE PLUMBING FIXTURE IS CLEANSED AFTER
EACH FLUSH WITHOUT SPLASHING WATER OUT FROM
THE LIP AND A QUIET FLUSHING CYCLE IS ACHIEVED.
NEVER OPEN CONTROL STOP TO WHERE THE FLOW
FROM THE VALVE EXCEEDS THE FLOW CAPABILITY
OF THE FIXTURE. IN THE EVENT OF A VALVE FAILURE,
Shut off Control Stop and remove
C
Flushometer Cover. Reinstall Inside Parts
THE FIXTURE MUST BE ABLE TO ACCOMMODATE A
CONTINUOUS FLOW FROM THE VALVE.
Assembly and Flushometer Cover. Tighten Cover with wrench. Open Control Stop and activate Flushometer Valve.
Adjust Control Stop to meet ow
D
rate required for proper cleansing of xture. Open Control Stop
NEVER OPEN THE CONTROL STOP TO
WHERE THE FLOW FROM THE VALVE EXCEEDS
THE FLOW CAPABILITY OF THE FIXTURE. IN THE
EVENT OF A VALVE FAILURE, THE FIXTURE MUST
BE ABLE TO ACCOMMODATE A CONTINUOUS
COUNTERCLOCKWISE ONE FULL turn from closed position. Activate
Flushometer. Adjust Control Stop after each ush until the rate of ow delivered properly cleanses the xture.
TROUBLESHOOTING GUIDE
1. Flushometer does not function (no flush).
A. Control Stop or Main Valve is Closed. Open Control Stop or Main Valve. B. Handle or Push Button Assembly is worn. Install Sloan Handle Repair Kit
(C-70-A) or replace handle or push button.
C. Relief Valve is worn. Replace Royal Performance Kit (Royal) or Inside Parts Kit
(Regal).
2. Volume of water is not sufficient to siphon fixture.
A. Control Stop is not open wide enough. Adjust Control Stop for desired delivery of
water volume.
B. Urinal ushometer parts installed in a Closet ushometer. Replace inside Urinal
Flushometer parts with proper Closet Flushometer parts.
C. Incorrect Dual Filtered Diaphragm Assembly (Royal Flushometers) or Inside Parts
Kit (Regal Flushometers) is installed in ushometer; for instance, Urinal assembly inside a Closet ushometer, or Low Consumption assembly inside a higher consumption xture. Determine the ush volume required by the xture and replace Royal Performance Kit or Inside Parts Kit. Use valve label and markings on xture for reference.
D. Water supply volume or pressure is inadequate. If no gauges are available to
properly measure supply pressure or volume of water at the Flushometer, then remove the Relief Valve from the Dual Filtered Diaphragm Assembly (Royal) or Inside Parts Kit (Regal), reassemble the ushometer and completely open the Control Stop. If the xture siphons, more water volume is required.
IMPORTANT — LAWS AND REGULATIONS PROHIBIT THE
USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON FIXTURE OR FLUSHOMETER.
If the xture does not siphon or if a Low Consumption ush is required, steps must
be taken to increase the water supply pressure and/or volume. Contact the xture manufacturer for minimum water supply requirements of the xture.
3. Flushometer closes off immediately.
A. Ruptured or damaged diaphragm. Replace Royal Performance Kit (Royal) or Inside
Parts Kit (Regal).
B. For Regal Flushometers — An enlarged bypass orice from corrosion or
damage. Replace Inside Parts Kit.
4. Length of flush is too short (Short Flush).
A. For Regal Flushometers — The Diaphragm Assembly and Guide Assembly
are not hand tight. Screw the two assemblies hand tight.
B. For Regal Flushometers — An enlarged bypass orice from corrosion or
damage. Replace Inside Parts Kit.
C. Dual Filtered Diaphragm Assembly (Royal) or Inside Parts Kit (Regal) is damaged.
Replace Royal Performance Kit or Inside Parts Kit.
D. Incorrect Dual Filtered Diaphragm Assembly (Royal) or Inside Parts Kit (Regal) is
installed in Flushometer; for instance, Urinal assembly inside a Closet Flushometer, or Low Consumption assembly inside a higher consumption xture. Determine the ush volume required by the xture and replace Royal Performance Kit or Inside Parts Kit. Use valve label and markings on xture for reference.
E. Handle or Push Button Assembly is worn. Install Sloan Handle Repair Kit
(C-70-A) or replace handle or push button.
5. Length of flush is too long (Long Flush) or continuous.
A. For Royal Flushometers — Metering bypass hole in Diaphragm is
clogged. Remove the Dual Filtered Diaphragm Assembly. Remove the Primary and Secondary Filter Rings from the Diaphragm and wash under running water. Replace Royal Performance Kit if cleaning does not correct the problem.
B. For Regal Flushometers — Relief Valve (A-19-A) is not seating properly or
bypass orice is clogged. Disassemble the working parts and wash thoroughly.
NOTE: SIZE OF THE ORIFICE IN THE BYPASS IS OF UTMOST
IMPORTANCE FOR THE PROPER METERING OF WATER INTO THE UPPER CHAMBER OF THE FLUSHOMETER. DO NOT ENLARGE OR DAMAGE THIS ORIFICE. REPLACE INSIDE PARTS KIT IF CLEANING DOES NOT CORRECT PROBLEM.
C. Supply line water pressure has dropped and is not sufcient to close the valve.
Close Control Stop until pressure is restored.
D. Dual Filtered Diaphragm Assembly (Royal) or Inside Parts Kit (Regal) is damaged.
Replace Royal Performance Kit or Inside Parts Kit.
E. Incorrect Dual Filtered Diaphragm Assembly (Royal) or Inside Parts Kit (Regal) is
installed in Flushometer; for instance, Urinal assembly inside a Closet ushometer, or Low Consumption assembly inside a higher consumption xture. Determine the ush volume required by the xture and replace Royal Performance Kit or Inside Parts Kit. Use valve label and markings on xture for reference.
F. White Closet Relief Valve has been used in a Urinal ushometer. Replace Closet
Relief Valve (A-19-AC) with Black Urinal Relief Valve (A-19-AU). G. Inside Cover is cracked or damaged. Replace the Inside Cover (A-71). H. Conditions in the piping system may contribute to the noise. A degree of high
pressure in the piping may be relieved by adjustments to Control Stop. Other
noises created by loose pipes, lack of air chambers, inadequate pipe sizes, etc.,
are problems that must be discussed with the building engineer.
6. Chattering noise is heard during flush.
A. Inside Cover is damaged. Replace Inside Cover (A-71). B. For Regal Flushometers — A-156-A Segment Diaphragm has been
installed upside-down. Reposition the Segment Diaphragm properly (see markings
on the Diaphragm).
7. Leaking at Handle or Push Button Assembly.
A. The B-39 Seal is worn or deteriorated. Install new B-39 Seal.
NOTE: The B-39 Seal will easily slide onto the B-40 Bushing if
it is wet.
B. Handle gasket has been omitted. Install A-31 Handle Gasket or Sloan Handle
Repair Kit (C-70-A). C. Valve Handle Bushing is worn. Install Sloan Handle Repair Kit (C-70-A).
When further assistance is required, please contact your
local Sloan Representative or Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
or visit us online at: www.sloanvalve.com
!!! IMPORTANT !!!
!!! IMPORTANT !!!
FLOW FROM THE VALVE.
5
Page 6
CARE AND CLEANING
DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean Flushometers that may dull the luster and attack the chrome or special decorative nishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the Flushometer from any splattering of cleaner. Acids and cleaning uids will discolor or remove chrome plating.
PARTS LIST
8B
12
8A
14
15
2
5
6
7
18
17
19
MODEL 152
8B
13
16 16
21
MODEL 142
12
MODEL 153
INSTALL WITH FLANGE AGAINST SPUD
12
8B
16
OPTIONAL (SEE PIPING DETAIL AT RIGHT)
8B
16
2020
17
18
19
22
8B 8B
22
17 18
MODEL 195 MODEL 197
26 910
3
12
12
19
8A
4
1
MODEL 143 MODEL 144
8B
16
21
INSTALL WITH FLANGE AGAINST SPUD
MODEL 154
16
17 18
10
20
19
8A
23
Item Part Description No. No.
1 Valve Body 2 H-730-A Bak-Chek
®
Control Stop 3 K-46 Gasket 4 A-6 Coupling 5 C-43-A 3” (76 mm) Push Button Actuator Assembly 6 C-9-A Blind Nut Push Button Actuator Assembly 7 B-12-A Lever Actuator Assembly 8A V-500-AA ¾” (19 mm) Vacuum Breaker Assembly RB† 8B V-500-AA 1½” (38 mm) Vacuum Breaker Assembly RB† 9 F-2-AW ¾” (19 mm) Slip Joint Coupling RB 10 F-15-A ELL with ¾” (19 mm) Tail RB (Models 195 and 197) 11 F-2-A 1½” (38 mm) Slip Joint Coupling 12 F-21 1½” (38 mm) Double Slip Elbow 13 F-2-A 1½” (38 mm) Coupling with S-21 Gasket (for Model 154,
Order Part Number F-5-A) 14 F-110 1-1/4” (32 mm) Outlet Tube 15 F-2-AU 1-1/4” (32 mm) Slip Joint Coupling RB 16 F-2-AA 1-1/2” (38 mm) Slip Joint Coupling (Set of Two) 17 F-102 1-1/2” (38 mm) Outlet Tube CP (for Models 143 and 144,
Order Part Number F-100) 18 F-7 Flange (Not Furnished with Models 143 and 144) 19 F-5-A 1-1/2” (38 mm) Spud Coupling Assembly CP 20 F-25-A 1-1/2” (38 mm) Elbow Assembly 21 F-100 1-1/2” (38 mm) Outlet Tube RB (for Model 154, Order
Part Number F-102) 22 F-15-A 1-1/2” (38 mm) Elbow Assembly CP 23 F-15-A ELL with 3/4” (19 mm) Tail CP (Model 197) 24 F-5-A 1-1/4” (32 mm) Spud Coupling Assembly CP 25 F-5-A 3/4” (19 mm) Spud Coupling Assembly CP 26 F-25-A 1-1/4” (32 mm) Elbow Assembly 27 V-500-A 1-1/2” (38 mm) Vacuum Breaker Assembly RB (Model 150) F-22 1” (25 mm) Female Outlet RB F-2-A 1-1/2” (38 mm) Coupling with S-21 Gasket
† Part number varies with valve model variation; consult factory.
Manufactured in the U.S.A by Sloan Valve Company under one or more of the following patents: U.S. Patents. 5,295,655; 5,542,718; 5,558,120; 5,564,460; 5,730,415; 5,865,420; 5,887,848; 5,967,182. Other Patents Pending. Bak-Chek
®
, Para-o®, PERMEX®, Turbo-Flo
®
MODEL 140
16
12
MODEL 150
27
MODEL 190 MODEL 192
11
13
18
25
NOTE: The information contained in this document is subject to change without notice.
12
13
12
17 18
24
SLOAN • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 1-800-9-VALVE-9 or 1-800-982-5839 • Fax: 1-800-447-8329 • www.sloanvalve.com
© 2014 SLOAN VALVE COMPANY Code No. 0816170 – Rev. 3 (04/14)
6
Loading...