TG10R TECHNICAL SPECIFICATIONS:
Output Power Rating 15 watts THD 0.9% 20Hz - 20kHz Signal To Noise -58dB Input Signal Level 50mV Input Impedance 600 ohms Speaker 8” 8 ohm 30 watt Input Power Requirements 120 VAC, 60Hz, 30VA
230VAC, 50Hz, 30VA
Cabinet Size and Weight 12” H x 12-1/2” W x 7” D, 16.5 lbs.
The TG10R is covered with a durable Tolex material: wipe it clean with a lint-free cloth.
Never spray cleaning agents onto the cabinet. Avoid abrasive cleansers which would damage the finish.
Crate continually develops new products, as well as improves existing ones. For this reason, the specifications
and information in this manual are subject to change without notice.
www.crateamps.com
@2004 SLM Electronics, a division of St. Louis Music, Inc • 1400 Ferguson Avenue • St. Louis, MO 63133
18-950-02 • 05/17/04
User ’s Guide
TG10R
Guitar Amplifier
TG10R
Guitar Amplifier
Block Diagram:
INPUT
POWER
AMP
REV
LEVEL
B+ B–
PREAMP
CD
INPUT
CLEAN
OD/
CLEAN
LEVEL
OD
LEVEL
EQUALIZATION
HIGH
AC POWER
LOW
POWER SUPPLY
POWER LED
POWER SW
SPEAKER
HEADPHONES
TG10R
Guitar Amplifier
TG10R
Guitar Amplifier
1: INPUT: Connect your guitar to this jack by means of a shielded instrument cable. 2: OD LEVEL: Use this control to adjust the volume and intensity of the Overdrive
channel. This control is only active when the OD/Clean switch (#3) is depressed.
3. OD/CLEAN: Use this switch to select the OD channel (switch depressed) or the Clean channel (switch in the out position). The OD channel gives you sounds rang­ing from crunchy rhythm to screaming leads, while the Clean channel gives you sounds from sparkling clean to slightly crunchy.
4: CLEAN LEVEL: Use this control to adjust the volume of the Clean channel. This control is only active when the OD/Clean switch (#3) is in the out position.
5: HIGH: Use this control to adjust the output level of the high frequencies. Rotating this control counter clockwise reduces the high frequency output; rotating it clock­wise increases it.
6: LOW: Use this control to adjust the output level of the low frequencies. Rotating this control counter clockwise reduces the low frequency output; rotating it clock­wise increases it.
7. REV LEVEL: Use this control to adjust the amount of reverberation added to the signal. With the control in the fully counter clockwise position the signal is “dry” (no reverb). As you rotate the control clockwise the amount of reverb increases.
8. CD INPUT: Use these RCA jacks to connect an external source (such as a CD player, tape player or rhythm machine) to the amplifier. The signal at these jacks is summed into a mono signal which is sent to the internal power amp circuit. Use the external source’s output level control to adjust the signal for the proper mix with your instrument.
9: HEADPHONES: Use this jack to connect a pair of stereo headphones for private listening. The external speaker is disconnected when headphones are in use.
10: POWER LED: This LED illuminates when power is applied to the amplifier. 11: POWER SWITCH: Use this switch to turn the amplifier on (top of the switch
depressed) and off (bottom of the switch depressed). 12: AC LINE IN: (Rear panel, not shown) The grounded power cord should only
be plugged into a grounded power outlet that meets all applicable electrical codes and is compatible with the voltage, power, and frequency requirements stated on the rear panel. Do not attempt to defeat the safety ground connection.
Congratulations and thank you for choosing the Crate TG10R Guitar Amplifier .
This rugged amplifier provides you with serious clean and distorted sounds and fea­tures two bands of equalization, reverb, CD Input jacks, and a jack for headphones.
In order to get the most out of your new amplifier, we strongly urge you to read this user’s guide before you begin playing.
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW, HEED, AND KEEP ALL INSTRUCTIONS AND WARNINGS.
DO NOT OPERATE NEAR ANYHEAT SOURCE AND DO NOTBLOCK ANY VENTILATION OPENINGS ON THIS APPARATUS. FOR
PROPER OPERATION, THIS UNITREQUIRES 3” (75mm) OF WELLVENTILATED SPACE AROUND HEATSINKS AND OTHER AIR FLOW PROVISIONS IN THE CABINET.
DO NOT USE THIS APPARATUS NEAR SPLASHING, FALLING, SPRAYING, OR STANDING LIQUIDS.
CLEAN ONLY WITH LINT-FREE DAMPCLOTH AND DO NOT USE CLEANING AGENTS.
ONLY CONNECT POWER CORD TO A POLARIZED, SAFETY GROUNDED OUTLET WIRED TO CURRENT ELECTRICAL CODES AND
COMPATIBLE WITH VOLTAGE, POWER, AND FREQUENCYREQUIREMENTS STATED ON THE REAR PANELOF THE APPARATUS.
PROTECT THE POWER CORD FROM DAMAGE DUE TO BEING WALKED ON, PINCHED, OR STRAINED.
UNPLUG THE APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME.
ONLY USE ATTACHMENTS, ACCESSORIES, STANDS, OR BRACKETS SPECIFIED BY THE MANUFACTURER FOR
SAFE OPERATION AND TO AVOID INJURY.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK OR FIRE, DO NOT EXPOSE THIS UNITTO RAIN OR MOISTURE.
SERVICE MUST BE PERFORMED BY QUALIFIED PERSONNEL.
OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEVELS. CONTINUED EXPOSURE TO HIGH SOUND
PRESSURE LEVELS CAN CAUSE PERMANENT HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR PRO­TECTION IS RECOMMENDED IF UNIT IS OPERATED AT HIGH VOLUME.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOIS­TURE. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL" “ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES.” "REFERREZ-VOUS AU MANUAL D'UTILISATION"
EXPLANATION OF GRAPHICAL SYMBOLS: EXPLICACION DE SIMBOLOS GRAFICOS: EXPLICATION DESSYMBÔLES GRAPHIQUES:
"DANGEROUS VOLTAGE" “VOLTAJE PELIGROSO” "DANGER HAUTE TENSION"
=
=
PRECAUCION
RIESGO DE CORRIENTAZO
NO ABRA
PRECAUCION: PARA REDUCIR EL RIESGO DE INCENDIOS O DESCARGAS ELECTRICAS, NO PERMITA QUE ESTE APARATO QUEDE EXPUESTO A LA LLUVIA O LA HUMEDAD. PARA DISMINUOIR EL RIESGO DE CORRIENTAZO. NO ABRA LA CUBIERTA. NO HAY PIEZAS ADENTRO QUE EL USARIO PUEDO REPARAR DEJE TODO MANTENIMIENTO A LOS TECHNICOS CALIFICADOS.
ATTENTION
RISQUE D'ELECTROCUTION
NE PAS OUVRIR
ATTENTION: PROTÉGEZ CET APPAREIL DE LA PLUIE ET DE L'HUMIDITÉ AFIN D'ÉVITER TOUT RISQUE D'INCENDIE OU D'ÉLECTROCUTION. POUR REDUIRE D'ELECTROCUTION NE PAS ENLEVER LE COUVERCLE. AUCUNE PIECE INTERNE N'EST REPRABLE PAR L'UTILISATEUR. POUR TOUTE REPARATION, S'ADRESSER A UN TECHNICIEN QUALIFIE.
1 2 3 4 5 6 8 9
7
10
11
Loading...