Craftsman 921.1531 User Manual

Page 1
Owner's Manual
AIR COMPRESSOR
3-gallon
1.5 HP (max developed) 1 HP Running
Oil Lubricated
Model No. 921.153100
CAUTION:
read this manual and follow all its Safety Rules and
Operating Instructions.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com/craftsman
06/17#2004 Part NO. E100731
Safety instructions
Installation & Operation
Maintenance & Storage
Troubleshooting Guide
Parts List
Espa_ol, p. 10
Page 2
TABLE OF CONTENTS
Page
Warranty ...................... ,................................................................................ see below
Safety Instructions ................................................................................................. 1
Important Safety Instructions & Guidelines ........................................................... 1
Specifications ......................................................................................................... 2
Glossary ................................................................................................................ 2
Duty Cycle ............................................................................................................. 2
Parts & Features ................................................................................................... 3
installation &Assembly ......................................................................................... 4
Operating Procedures ........................................................................................... 5
Maintenance .......................................................................................................... 6
Storage .................................................................................................................. 6
Troubleshooting Guide .......................................................................................... 7
Parts List................................................................................................................. 8
EspaSol.................................................................................................................... 10
Service Number.......................................................................................... back cover
ONE YEAR FULL WARRANTY ON CRAFTSMAN AIR COMPRESSOR
If thisCraftsman Air Compressor fails due to manufacturer's defects in material or workmanship
within one year of the date of purchase, RETURN IT TO THE NEAREST SEARS STORE OR SERVICE CENTER IN THE UNITED STATES and it will be replaced or repaired (at our option),
free of charge.
If this Air Compressor is used for commercia?or rental purposes, this warrantyapplies for only 90
days from the date of purchase. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA,
Hoffman Estates, IL 60179
Page 3
Safety Instructions
The information listed below should be read and understood by the operator. This information is given to
_rotect the user while operating and storing the air
compressor. We utnize the symbols below to allow the
reader to recognize important information about their
safety.
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
When used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may
result in property damage.
Important Safety Instructions and Guidelines
Save all instructions
Improper operation or maintenance of this product could result in serious injury and/or property damage. Read and
understand all of the warnings and safety instructions provided before using this equipment.
The air compressor should be operated on a dedicated 15 amp circuit. Ifthe circuit does
not have 15 free amps available, a larger circuit must be used. Always use more air hose before utilizing extension cords. All extension cords used must be 12 gauge with a maximum length of 25 ft. The circuit fuse type must be a time delay. Low voltage could
cause damage to the motor.
Risk of Moving Parts
If the air compressor is in operation, all guards and covers should be attached or installed correctly. If any guard or cover has been damaged, do not operate the
equipment until the proper personnel has correctly repaired the equipment. The power cord should be free of any moving parts, twisting and/or crimping while in use and while
in storage.
Risk of Burns
N
Risk of Falling
Risk from
Flying Objects
There are surfaces on your air compressor that while in operation and thereafter can cause serious burns if touched. The equipment should be allowed time to cool before any maintenance is attempted. Items such as the compressor pump and the outlet tube
are normally hot during and after operation.
Operation of the air compressor should always be in a position that is stable. Never use
the air compressor on a rooftop or elevated positionthat could allow the unit to fall or
be tipped over. Use additional air hose for elevated jobs.
Always wear ANSI Z87.1 approved safety glasses with side shields when the air compressor is in use. Turn off the air compressor and drain the air tank before
performing any type of maintenance or disassembly of the hoses or fittings. Never point any nozzle or sprayer toward any part of the body or at other people or animals.
Page 4
Important Safety Instructions & Guidelines
Risk to Breathing
Risk of
Electrical Shock
Risk of
Explosion or Fire
Risk of Bursting
Avoid using the air compressor in confined areas. Always have adequate space (12 inches) on all sides of the air compressor. Also keep children, pets, and others out of the area of operation. This air compressor does not provide breathable air for anyone
or any auxiliary breathing device. Spraying material will always need to be in another area away from the air compressor to not allow intakeair to damage the air compressor
filter.
Never utilize the air compressor in the rain or wet conditions. Any electrical issues or repairs should be performed by authorized personnel such as an electrician and should
comply with all national and local electrical codes. The air compressor should also have the proper three prong grounding plug, correct voltage, and adequate fuse protection.
Never operate the compressor near combustible materials, gasoline or solvent vapors. If spraying flammable materials, locate the air compressor at least 20 feet away from
the spray area. Never operate the air compressor indoors or in a confined area.
Always drain the air compressor tank daily or after each use. if the tank develops a leak, then replace the air compressor. Never use the air compressor after a leak has been
found or try to make any modifications to the tank. Never modify the air compressor's factory settings which control the tank pressureor any other function.
Specifications
Pump ...................... Oil-lube direct drive
Motor Induction ............... 1.5 HP max developed,
1HP running
Bore ....................... 1.65"
Stroke ...................... 1.26"
Voltage Single Phase ........... 120 VAC
Minimum Circuit Requirement .... 15 Amps
Air Tank Capacity ............. 3 Gallons
Cut-in Pressure ............... 95 PSI
Cut-out Pressure .............. 125 PSI
SCFM @ 90 PSI .............. 2.4
Glossary
CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure
for air delivery.
PSIG: Pounds per square inch gauge; a unit of measure
for pressure.
ASME: American Society of MechanicalEngineers. California Code: Unit may complywith California Code
462 (I) (2)/(M) (2).
Cut-In Pressure: The air compressorwill automatically
startto refillthe tank when the pressure drops below the prescribed minimum.
Cut-Out Pressure: The point at which the motor stops
when the tank has reached maximum air
pressure.
Code Certification: Products that bear one or more of
the following marks: UL, CUL, ETL, CSA, have
been evaluated by OSHA-certified independent safety laboratories and meet the applicable
Underwriters Laboratories Standards for Safety.
Duty Cycle
This is a 50% duty cycle air compressor. Do not run the air compressor more than 30 minutes of one hour. Doing so could damage the air compressor.
2
Page 5
Parts & Features
See figures below for reference.
Air Intake Filter
Provides clean air to the pump and must always be kept free of debris. Check on a daily basis or before each use.
Indicates the outgoing air pressure to the tool and is controlled
I Regulator Gauge
by the regulator.
Tank Pressure Gauge
Indicates the reserve air pressure inthe tank.
Outlet Tube
Oil Fill Cap
Pressure Switch
Thiscontrolsthe powerto the motorand also the cut-in/cut-outpressuresettings. This switchserves as theAuto-On/Off positionsfor the unit,
J
Pressure Relief Valve
The pressure relief valve located on the side of the pressure switch, isdesigned to
automaticallyrelease compressedair when the air compressor reaches cut-out pressure.
The released air should onlyescape
momentarilyand the valve shouldthen close.
Used to allow excess tank pressure to
escape into the atmosphere.This valve
Safety Valve 1
should only open when the tank pressure
isabove the maximum ratedpressure.
Re_,.gulator
Ine air pressure coming from the air tank is
controlled by the regulator. To increase the
pressure turn the knob clockwise and to
Pressure
Relief Tube
Quick Connect 1Offers a quick release feature for attaching and removing the air hose.
Tank Drain Valve /
Oil Sight Gauge
I Check Valve 1When the pump is not in operation the valve closes to retain air pressure inside the tank. An internal component.
Used to drain condensation from the air tank, Locatedat bottom of tank.
decrease the pressure turn the knob counterclockwise.
Page 6
Installation & Assembly
The air compressor should be turned off and unplugged from
the power source before any maintenance is performed as well as the air bled from the tank and the unit allowed time
to cool. Personal injuries could occur from moving parts, electrical sources, compressed air or hot surfaces. The regulator assembly must be attached before use. Failure to assemble correctly could result in leaks and possible injury. If unsure of assembly instructions or you experience difficulty in the assembly please call your local service department for
further instruction.
Quick Connect Assembly
1. Before assembly be sure that the Quick Connect (Q.C.) threads have a sealant applied from the factory to prevent
leaks around the threads. If no sealant is present, wrap the threaded portion with
Teflon tape.
2. Attach the Q.C. assembly to the air compressor by
aligning the Q.C. threads to the regulator on the manifold. Be certain to align the threads before tightening to prevent thread damage.
3. The assembly should turn clockwise 1 to 1.5 revolutions
after hand-tightening with a 13/16ths size wrench. To prevent damage and leaks, do not over-tighten.
To Install the Air Intake Filter
Remove the air intake filter from the poly bag and thread it onto the head
of the compressor as shown.
Do not attempt to start the air compressor without first adding
oil to the crankcase. Serious damage can result unless filled with oil. The pump is shipped without oil from the factory. Only use non-detergent oils since multi-viscosity motor oils
leave carbon deposits on pump components, thus reducing performance and compressor life.
Drain the tank to release all tank air _ _.=t_{ '_L pressure before removing the oil fill cap.
Be sure the air vent in the oil fill cap (see figure to the right) is free from debris.
If air vent is blocked, pressure can build
in crankcase causing damage to the compressor and possible personal injury.
Lubrication and Oil Remove the oil fill cap by turning it _ /_-,,,
counter-clockwise by hand. Fill the compressor pump with an air compressor
oil such as SAE-30 non-detergent (API CG/CD Heavy Duty) oil at slow intervals
until the oil reaches the center of the red circle in the sight glass ( see figure above).
Use SAE-10 during extreme winter conditions.
Location of the Air Compressor
The air compressor should always be located in a clean, dry, and well ventilated environment. The unit should have
at minimum, 12 inches of space on each side. The air filter intake should be free of any debris or obstructions. Check the air filter on a daily basis to be sure it is clean and in working order.
Grounding instructions
This product should be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by providingan escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. (See the figure below.) The plug must be plugged intoan outlet that isproperly installed and grounded in accordance with all local codes and ordinances.
Check with a qualified electrician or service
personnel if these
instructions are not
completely understood or if in doubt as to
whether the tool is
properly grounded.
improper installation of the grounding plug will result in a risk of electric shock. If repair or replacement of the cord
or plug is necessary, do not connect the grounding wire to
either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is
the grounding wire. Check with a qualified electrician or
serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the product is
properly grounded. Do not modify the plug provided; if it will not fit the outlet, have the proper outlet installed by a
qualified electrician. This product is for use on a circuit having a nominal rating
of 120 volts and is factory-equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be
used with this product. If the product must be reconnected
for use on a different type of electric circuit, qualified service
personnel should make the reconnection.
Extension Cords Use only a 3-wire extension cord that has a 3-blade
grounding plug, and a 3-slot receptacle that will accept the plug on the product. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will
draw. Cords must not exceed 25 feet and No. 12 AWG size must be used. An undersized cord will cause a drop in line
voltage resulting in loss of power and overheating.
Break In Procedures
No break in procedure is required by the user. This product is factory tested to ensure proper operation and performance.
Grounding Pin
Outlet
Grounded
Page 7
Operating Procedures
Daily Start-Up Procedures
(_)Set the Auto-On/Off lever to the Off position. (_)oCrheCkthe air compressor visually for any damage
obstruction.
(_CIose the drain valve. (_)Check the oil level of the pump.
_tthonnect the air hose to the quick connect socket on
e regulator assembly by inserting the quick connect
plug on the air hose into the quick connect socket. The quick connect socket collar will snapforward and lock
the plug intoplace providing an air tight seal between the socket and plug. To release the air hose push the
collar back on the quick connect socket.
(_Plug the power cord into the proper receptacle.
(_Turn the Auto-On/Off lever to the On-Auto position and
the compressor will startand build air pressure in the tank to cut-out pressure and then shut off automatically.
(_)Adjust the regulator to a PSI setting that is needed for
your application and be sure it is within the safety standards required to perform the task. If using a
pneumatic tool, the manufacturer should have recommendations in the manual for that particular
tool on operating PSi settings.
Note: The air compressor is now ready for use. The
following inflation and cleaning accessories packaged with this unit should only be operated at maximum
pressure of 20-30 PSI: blow gun, tapered nozzle, inflation needles, blow gun adapter.
Dally Shut-Down Procedures
1. Set the Auto-On/Off lever to the Off position.
2. Unplug the power cord from the receptacle.
3. Set the outlet pressure to zero on the regulator.
4. Remove any air tools or accessories. When draining the tank, always use ear and eye protection, Drain the
tank in a suitable location; condensationwillbe present
in mostcases of draining.
5. Open the drain valve allowing air to bleed from the tank. After all of the air has bled from the tank, close
the drain valve to prevent debris buildup in the valve,
When draining the tank, always use ear and eye protection.
Drain the tank in a suitable location; condensation will be present in most cases of draining.
Water that remains in the tank during storage will corrode and weaken the air tank which could cause the tank to
rupture. To avoid serious injury, be sure to drain the tank after each use or daily.
Page 8
Maintenance
NOTE: Any service procedure not covered in the maintenance schedule below should be performed by qualified service
)ersonnel.
Items to Check/Change
Check Tank Safety Valve Overall Unit Visual Check
Check Oil Level Change Oil
Check Air Filter (more frequently in dusty or humid environments) Drain Tank (after each use or daily)
To ensure efficient operation and longer life of the air
compressor unit, a routine maintenance schedule should be followed. The following schedule is geared toward a consumer whose compressor is used in a normal working
environment on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your
compressor is used. The modifications will depend upon the hours of operation and the working environment. Air
compressors used in an extremely dirty and/or hostile
environment will require a greater frequency of all maintenance checks.
Before each
use or daily
X X
X
X X
The air compressor should be turned off and unplugged from the power source before any maintenance is
performed as well as the air bled from the tank and the unit allowed time to cool. Personal injuries could occur
from moving parts, electrical sources, compressed air or hot surfaces.
After first
10 hours
X
Every
100 hours
Oil Changing
For changing the pump 0il, be sure to do the following:
1. Turn the unit off and unplug the power cord from the receptacle.
2. Allow the compressor time to cool if it has been in operation.
3. Open the drain valve to bleed all air from the tank.
4. Close the drain valve.
5. Remove the oil fill cap on the pump.
6. Remove the sight glass with a box end wrench or socket. Drain the oil into a suitable container and
dispose of properly. The compressor may need to be tipped slightly towards the drain hole to allow all of the oil to drain.
Storage
For storingthe air compressor, be sure to do the following:
1. Turn the unit off and unplug the power cord from the receptacle.
2. Remove all air hoses, accessories, and air tools from
the air compressor.
3. Perform the daily maintenance schedule.
7. Reattach the sight glass. Note: Torque the sight glass 10-12 inch Ibs. when re-assembling. Be sure the gasket
is between the sight glass and the pump crankcase.
8. Refill the compressor pump with an air compressor oil
such as SAE-30 non-detergent (API CG/CD Heavy
Duty) oil at slow intervals until the oil reaches the center of the red circle in the sight glass. Use a SAE-10 during extreme winter conditions.
4. Open the drain valve to bleed all air from the tank.
5. Close the drain valve.
6. Store the air compressor in a clean and dry location.
Page 9
Troubleshooting Guide
The air compressor should be turned off and unplugged from the power source before any maintenance is performed as well as the air bled from the tank and the unit allowed time to cool.
Personal injuries could occur from moving parts, electrical sources, compressed air, or hot surfaces.
PROBLEM POSSIBLE CORRECTION
Air leaks at the check valve A defective check valve results in a constant air leak at the pressure relief valve or at the pressure relief valve, when there is pressure in the tank and the compressor is shut off. Drain the tank,
then remove and cleanor replace the check valve.
Air leaks between head and Be sure of proper torque on head bolts. If leak remains, contacta servicetechnician.
cylinder.
Air leak from safety valve. Operate the safety valve manually by pullingon the ring. If the valve continues to
leak when in the closedposition,it should be replaced.
Pressure reading on the regulated pressure gauge
drops when an accessory is
used.
Excessive tank pressure. Move the Auto-On/Off lever to the Off position. If the unit doesn't shut off, unplugit
Motor will not start. Make sure power cord is plugged in and the switch is on. Inspect for the proper size
Excessive moisture in the discharge air.
If there is an excessive amount of pressure drop when the accessory is used,
replace the regulator.
NOTE:
Adjust the regulated pressure under flow conditions(while accessory is being used),
It is normal for the gauge to show minimal pressure loss during initial use of the
tool.
from the power source and contact a service technician.
fuse in your circuit box. If the fuse was tripped, reset it and restart the unit. If repeated tripping occurs, replace the check valve or contact a service technician.
Remove the water in the tank by draining after each use. High humidity
environments will cause excessive condensation. Utilize water filters on your air
line.
NOTE:
Water condensation is not caused by compressor malfunction. Be sure the
compressor's air output is greater than your tool's air consumption rate.
Air leaks from the tank body
or tank welds.
Never drill into, weld or otherwise modify the air tank or it will weaken. The tank can rupture or explode. Compressor cannot be repaired. Discontinue use of the air compressor.
Page 10
Craftsman Air Compressor Model 921.153100
Parts List
i _j33
20J _j3,
I F
I
31
I
! ._"_ 35
/
,_ 32
51
50
5
/
52
53
8
Page 11
Craftsman Air Compressor Model 921.153100
Parts List
Reference
Number
1
2
3
4
5 6
7 8
9
10
11
12
13 14
15 16 17 18
19 20
21 22 23
24 25
26 27
28 29
3O 31
32 33 34
35
36
37 38
39 40
Kit Part Description Quantity
Number Number
1
1
2
EI00434 IntakeFilterHousing, 1
1/2NPT(Kunsan)
E100435 FilterElement(Kunsan) 1
HeadBolt,M8x 1.0x 30 4 LockWasher,6mm 8
E100227 CylinderHead 1
E100085 ExhaustElbow 1
Gasket,Head 1
E100228 ValvePlate 2
E100229 ValveReed 2 2 2
3 2
3 3
3 3
3 3
3
3
4 4
E100235
5 5
2 6
E100248 E100247
E100955 E100956
Gasket,ValvePlate 1 Gasket,CylinderUpper 1
Cylinder,ID42mmx H65mm 1
Bolt,M6x 1.0x 20 5
Gasket,CylinderLower 1
Ring,Compression 2 Ring,Scraper 1
Piston 1 PistonPin 1
SnapRing,12mm 2 RodConnecting 1 Nut,M6x 1.0 1 Eccentric 1
OilFillCap 1 O Ring,OD17mmx2mm 1 Cover,Crankcase 1 Bolt,M5x0.8x 15 10
Seal,OilSightGauge 1 Oil SightGauge 1
RubberBaffle I Nut,M8x1.25 10
Washer,Flat8ram 2
Screw,M3x0.5x 6 4 SpringWasher,3ram 4
Capacitor,Starting(200pF) 1 Capacitor,RunningHOpF) 1
CrankCase 1 Motor 1 Cover,MotorRear 1
Shroud 1
PressureReliefTubeAssy 1
:_eference Kit Part
Number Number Number
41 E100957 PressureSwitch 42 E100594 StrainRelief 48 E100205 PressureGuage,2" 200PSI 44 E100093 PressureGuage,1.5"200PSI
45 E100094 SafetyValve 46 E100059 Regulator
47 E100091 Coupler,QuickConnect 1 48 E100595 Nipple,1/4"NPTx 27ram 1
49 E100598 Nipple,1/4"NPTx 80mm 1
50 OutletTubeAssy 1 51 E100097 Grip,Handle 1
52 Tank 1 53 E100098 DrainValve,1/4"NPT 1
54 E100099 CheckValve 1 55 6 FlatWasher,8ram 16
56 6 Isolator,Rubber 4 57 6 Bolt,M8x 1.25mmx20mm 4
58 E100101 PowerCord14/3x 6' 1 59 Bolt,M8x 1.25ramx25ram 4
NotShown E100110 Label,DrainTankWarning 1 NotShown E100370 Label,SpecificationHP,Tanksize 1
NotShown E100859 Label,WarningBilingualTank 1 NotShown E100731 Manual,Operators/Parts 1
Note:AnypartJkltnumberfieldwithouta numberisnotavailable. Descriptionsareprovidedforreferenceonly. TheKit# columnrepresents
thatthepartbeingofferedisavailableinakit.Oneof eachpartperkitwill beoffered.
Kitnumberandpartsthatareincludedareasfollows: KitNo. PartNo. Description ReferenceNo.
1 E100434 IntakeFilterKit 1,2
2 E100959 GasketKit 7, 10-11,14,29
3 E100251 PistonKit 13,15-22
4 E100087 OilFillCapw/O-ring 23-24
5 E100088 OilSightGaugew/O-ring 27-28 6 E100102 IsolatorKit 30,55-57
Description Quantity
1 2
1 1
1 1
Page 12
CONTENIDO
P.Sgina
Garantfa ............................................... esta p&gina
Instrucciones de seguridad ......................................... 11
Instrucciones y pautas de seguridad importantes ........................ 11
Especificaciones ................................................ 12
GIosario ....................................................... 12
Ciclo de trabajo ................................................. 12
Partes y caractedsticas ........................................... 13
Instalaci6n y ensamblaje .......................................... 14
Procedimientos de operaci6n ....................................... 15
Mantenimiento .................................................. 16
Almacenamiento ................................................ 16
Diagn6stico y correcci6n de fa_las ................................... 17
Lista de partes .................................................. 8
GARANT|A DE UN AI_IO SOBRE COMPRESOR DE AIRE CRAFTSMAN
Si este compresor de aire Craftsman llega a fallar debido a defectos de manufactura o de matedales atribuibles al fabricante en un plazo de un aSo desde lafecha de compra, DEVUI_LVALO
A LA TIENDA O CENTRO DE SERVICIO SEARS M/_S CERCANO EN LOS ESTADOS UNIDOS para que le sea reemplazado o reparado (a opci6n nuestra) sin ning_n cargo.
Si este compresor de aire se usa con fines comerciales o de renta, esta garantfa L_nicamente aplica por 90 (noventa) dfas a partir de la fecha de compra. Esta garantia le da derechos legales
especfficos; adem&s, es posible que usted tenga otros derechos, los cuales varfan segL_nel estado.
Sears, Roebuck and Co., Dept. 817WA,
Hoffman Estates, IL 60179
10
Page 13
Instrucciones de seguridad
El operador debe leer y entender la informaci6n siguiente. Esta informaci6n se ofrece para proteger al usuario durante la operaci6n y el almacenaje del
compresor. Los sfmbolos siguientes son los qua se utilizan para indicar al lector informacion qua es
importante para su seguridad.
Indica una situaci6n de riesgo inminente que, de no evitarse, provocarfa lesiones graves o la muerte.
Indica una situaci6n potencialmente peligrosa qua, de no evitarse, podrfa provocar lesiones graves o la muerte.
Indica una situaci6npotencialmente peligrosa que, de no evitarse, podffa provocar lesiones menores o modaradas.
AI aparecer sin el sfmbolo de alerta de seguridad, indica una situaci6n potencialmente peligrosa qua, de no evitarse, podrfa causar dafios materiales.
Instrucciones y pautas de seguridad importantes
Guarde todas las instrucciones,
La operaci6n y el mantenimiento inadecuados de este producto pueden provocar lesiones graves y dafios materiales. Antes de utilizar este equipo, lea y entienda las advertencias e instrucciones de seguridad aquf contanidas.
El compresor de aire se debe operar desde un circuito dedicado de 15 amperes. Si el circuito no dispone de una capacidad de 15 amperes, se debe usar un circuito de mayor
capacidad. Si es necasario, antes de emplear una extensi6n el6ctrica, afiada una manguera de aire m_.slarga. Las extensiones el6ctricas deben ser de calibre 12 y tener
una Iongitud m_.xima de 7.6 metros. El fusible del circuito debe set de acci6n retardada. Un voltaje demasiado bajo pueda dafiar el motor.
Riesgo por partes en
movimiento
Antes de operar el compresor, todos los protectores y cubiertas deben estar instalados correctamenta. Si alguno de los protectores o cubiertas est& dafiado, no opera el
equipo sino hasta que personal calificado repare el problema. El cable de corriente se debe mantener alejado de las partes m6viles del equipo y no debe torcerse ni
prensarse durante su empleo ni al set almacenado.
Riesgo de quemaduras
i
Riesgo de cafda
Riesgo de lanzamiento
de objetos
En su compresor hay superficies que, de ser tocadas clurante y despu6s de su operaci6n, pueden causar quemaduras graves. Antes de darle mantenimiento al
equipo, sele debe dejar enfriar. Por Io normal, durante y despu6s de su operaci6n, ciertas partes como la bomba del compresor y el tubo de salida estaran calientes.
El compresor siempre se debe operar en una posici6n estable. Nunca utilice el comprasor sobre un techo o en una posici6n elevada desde donde podrfa caer o volcarse. AI trabajar en posiciones elevadas, utilice una manguera de aire mas larga.
AI emplear el compresor, siempre utilice anteojos de seguridad con protectores
laterales que cumplan con la norma ANSI Z87.1. Antes de Ilevar a cabo cualquier clase de mantenimiento y antes de desconectar las mangueras y acopladores, apague el compresor y drene el tanque de aire. Nunca apunte la boquilla o rociador hacia
ninguna parte de su cuerpo ni del de otros seres.
11
Page 14
Instrucciones y pautas de seguridadirnportantes (cont,)
Riesgo para la
respiraci6n
Riesgo de
descargas el_ctricas
Rlesgo de
explosi6n y fuego
Evite utilizar el compresor de aire en _reas encerradas. Siempre tenga un espacio libre adecuado (30 cm.) en todos losladosdel compresor.Tambi6nmantenga fuera del drea
do operaci6n a mascotas, ni6os y otras personas. Este compresor de aire no provee
aire que pueda ser respirado ni empleado con un dispositivo respiratorio auxiliar.El materialde rociadosiempredebera,estaren otra zona, alejado del compresor
de aire, para evitar que el aire aspirado daSe el filtro del compresor.
Nunca utilice el compresor de aire bajo Iluvia o en lugares mojados. Los problemas el_ctricos deben ser reparados por personal autorizado, tal como serfa un electricista,
y deben cumplir con las normas electricas nacionales y locales. El compresor tambi_n
debe toner la clavija apropiada de tres terminales y contar con un suministro el_ctrico que sea delvoltaje correcto y con un fusible de protecci6n adecuado.
Nunca opere el compresor cerca de materiales combustibles, gasolina ni vapores de solventes. Si est_l rociando materiales inflamables, coloque el compresor a una
distancia de cuando menos 6 metros del _.rea de rociado. Nunca opere el compresor de aire en interiores o on lugares cerrados.
Riesgo de estallido Drene el compresor diariamente o despuds de cada utilizaci6n. Si el tanque tiene una
fuga, reemplace el compresor. No utilice el compresor si se ha detectado una fuga, ni trate de modificar el tanque. Nunca modifique los ajustes de f_.bricadel compresor que
._ _1 _l_ ' controlan la pres,6n del tanque y dem,s funciones.
Especificaciones
Bomb ..... De impulsi6n directa, lubricada con aceite
Inducci6n del motor.. :...1.5 HP mdximo desarrollado,
1 HP funcionando
Di_.metro .......................... 1.65"
Carrera ........................... 1.26"
Voltaje monofasico .................. 120 VAC
Glosario
aCFM: Pies cdbicos per minute. SCFM: Pies c_bicos estdndar per minuto; unidad de
medici6n do suministro de aire.
PSIG: Libras por pulgada cuadrada sobre la presi6n
atmosfdrica; unidad de medici6n de presi6n.
ASME: Sociedad estadounidense de ingenieros mecanicos. C6digo de California: La unidad puede cumplir con el
c6digo de California 462 (1)(2)/(M) (2).
Capacidad mfnima del circuito ......... 15 A
Pies cL_bicosx min. (SCFM) a 90 LPPC .. 2.4
Capacidad del tanque de aire .......... 3 galones
Presi6n de arranque ................. 95 LPPC (PSI)
Presi6n de parada .................. 125 LPPC (PSI)
Pies cL_bicosx min. (SCFM) a 90 LPPC .. 2.4
Presi6n de arranque:El compresor arranca
autorndticamente cuando la presi6n baja a menos del mfnimo prescrito.
Presi6n de parada: Presibn de aire que tiene que alcan-
zarse en el tanque para que se detenga el motor.
Certificaci6n de c6digo: Los productos que tienen
alguna o varias de las siguientes marcas han sido evaluados por laboratorios de seguridad
independientes certificados por OSHA, y cumplen con las normas de seguridad de Underwriters
Laboratories: UL, CUL, ETL, CSA.
Ciclo de trabajo
Este compresor tiene un ciclo de trabajo de 50%. Nunca opere el compresor por m_s de 30 minutos cada hora. De hacerlo, podrfa daSarlo.
12
Page 15
Partes y caracterfsticas
Como referencia, yea las figuras de abajo.
Filtro de aire
Suministra aire Iimpio a la bomba. Siempre se le debe tenet libre de suciedad. Revfselo diariamente oantes de cada uso. (V_ase la imagon en la secciSn do ensamblaje.
Indica la presion de salidadel aire que se entrega a la herramienta
! t
presiSn que es contrelada por el regulador.
Mandmetro de presidn del tanque
Indica la presi6n de la reserva de aire del tanque.
Tubo de salida
Tap6n de Ilenado de aceite
Interruptor de presi6n
Controla el suministroel_ctricoal motor y tambi_n los[ ajustes de presi6n de arranque y presi6n de parada. | Este interruptor sirve como posici6nde autoencendidoI
y apagado (Auto-On/On de la unidad. J
Vdlvula de alivio de presi6n
Esta v_.lvula, que se encuentra en el costado
del interruptorde presi6n, esta disefiada para
Iiberaraire comprimidode manera automdtica
cuando el compresor Ilegue a la presi6n de
parada. El aire s61odeber_, escapar durante un instante, cerr_.ndosela v&lvulaen seguida.
de seguridad del tanque
Permite que el excese de presibnen el
tanque escape al medio ambiente. Esta v_.lvulas61ose abrir_cuando la presi6n
en el tanque este porencima de la presi6n mdximanominal del modelo.
Regulador
La presiSndel aire quesale deltanque es
controlada pot el regulador.Para aumentar la presi6n, gire la perilla en direcci6n de las
Vdlvula de
retenci6n
Conector de acoplamiento rdpido
Permite conectary desconectar r_pidamente ]a manguera de aire.
Sirve para drenar la condensaci6nacumulada en
Visor de aceite en la parte inferior del tanque.
V=_lvulade retenci6n
Cuande la bomba no est,. en operaciSn,esta v_.lvulase cierra para retener la presi6nde aire dentro del tanque. Es un cemponente interne.
I Vdfvula de drenado
13
manecillas; para disminuida,gire Laperilla en direcci6ncontrariaalas maneoillas.
el fonde del tanque. Se encuentra1
J
J
Page 16
Instalacibn y ensamblaje
Antes de dar mantenirniento al compresor de aire, se le debe apagar y desconectar de la fuente de poder, adem_s de purgar
el aire del tanque y dade suficiente tiempo pars enfriarse, Existe el desgo de que las partes m6viles, ]a fuente el_ctrica, el sire comprimido y las superficies calientes provoquen lesiones. El ensamble del regulador debe estar instalado antes de usar el cornpresor. Un ensamblaje inadecuado puede set causa de fugas y posiblemente de lesiones. Si no entiende las instruc- clones de ensamblaje o tiene dificultad pars Ilevar a cabo el armado, por favor Ilame a su departamento IocaJde servicio.
Conjunto de conexi6n r_pida _._|'\/
1. Antes de ensamblar, compruebe que ,_ i _ _
se haya aplicado de fabrica un sellador ..,.-=__c_ ,T-_i,, a la rosca del conector r_pido, con el fin _J_o_, ._ de evitar fugas por esa zona. Si no hay
sellador, enrolle la parte roscada con einta de tefldn.
2. Cone_e el conjunto de conexi6n rdpida al eompresor de
sire, alineando la rosca del conector r_.pido con el regulador
en el colector. Para evitar dados alas roscas, aseg0rese de
alinearlas eorrectamente antes de roscarlas.
3. El conjunto se debe apretar a mano en direcci6n horaria
y luego apretar de 1 a 1.5 vueltas con una Ilave de 13/16".
Para evitar da_ios y fugas, no apriete demasiado.
Instalaci6n del filtro de aire /_._. _ Saque el filtro de airede entrada de la
bolsa de poliuretanoy enr6squela en el cabezal de la compresora, come se rnuestra.
sin antes
adadir aceite al dep6sito. De no flenado de aceite y seguir el procedimiento de operaci6n, el compresor podria sufrir da_os
graves. La bomba sale de la fdbrica sin aceite. En el depbsito queda una pequeFlacantidad de aceite, sobrante de las prue-
bas en la fdbrica, $61o use aceite no detergente, pues los aceites mulfigrado para motor dejan dep6sitos de carb6n en tos componentes de la bomba, reduciendo el desempefio y lavida del compresor.
Antes de quitar el tap6n de Ilenado de aceite, drene el tanque para liberar la presi6n de aire._ L_Z.j_ 'i,L
Compruebe que el respiradero del tapbn de 'i_ Ilenado de aceite est_ limpio (veala
ilustraci6n). Si est_ bloqueado, puede haber una acumulaci6n de presibn en el dep6sito, dadando el compresor y posiblemente causando lesiones al operador.
Lubricaci6n y sceite Quite el tapdn de Ilenado de aceite girdndolo %.
con la mano en direcci6n contrariaalas manecillas. Llene ]entamente la bomba del . _\\
compresor con aceite para compresor de sire, "{(f(_O "}'_/Y" como aceite SAE-30 no detergente (API ._._//'_..I
CG/CD de trabajo pesado) basts que Ilegue al centro del c[rculo rojo del visor, como se
muestra en la imagen. En condiciones extrernas de invierno use aceite SAE-10.
Ubicacl6n del compresor de aire
El compresor de sire siempre debe estar en un medio ambiente limpio, seco y bien ventilado. La unidad debe tener cuando menos 30 cm, de espacio libre en carla lado. La toms del filtro de sire debe estar libre de suciedad y obstrucoiones. Por favor revise diadamente el filtro de aire pars comprobar que est_ limpio yen correcto estado de funcionamiento.
Instrucciones de conexibn a tierra
Este producto se debe conectar a tierra. En caso de cortocircuito, la conexibn a tierra reduceel desgo de descargas el_ctricosal ofrecerun alambrede escape para la cordente
el_etdca. Este producto cuentacon un cable que tiene un alarnbre
de tierray una clavijaconterminalde tierra. La clavija debe
enchufarseen un tomacordenteinstaladoy puestoa tJerrasegL_n
las normas locales, Hable con un eleclricistao agente de servicio
calificadosino entiende
completamenteestas
instrucciones, o si tiene J'_-.-_i _%_-_-__ Grounded
dudas sobre la correcta _1_--_" ./ Outlet
puesta a tierra de
la herramienta. GroundingPin L_=_' I
Una conexibn a tierra inadecuada puede provocar una
descarga el_ctrica. Si necesita reparar o cambiar el cable
o la clavija, no conecte el alambre de tierra a ninguna de las
terminales planas. El a[ambre de tierra es el de color verde,
con o sin franjas amarillas. Si no entiende completamente las
instrucciones de conexi6n a tierra, o si tiene dudas sobre la
corrects puesta a tierra de Is herramienta, hable con un electricista
o agente de servicio calificado. No modifique la clavija que viene
con el equipo;si no puede enchufarla en el tomacordente, Ilame aun electdcista para que cambie el tomacorriente.
Este producto est_ disedado para trabajar en un cireuitocon un voltaje nominal de 120 volts y est_ dotado de fdbrica con un cable y clavija que permiten su conexi6n aun circuito eldctfico apropiado. AsegLirese de que el producto est_ conectado aun tomacordente con la mnismaconfiguraci6n que la clavija. No se debe usar un adaptador con este equipo. Si se debe conectar el equipo aun circuito el_ctrico de diferente tipo, consiga la ayuda de personal calificado.
Extensiones eldctricas
$61o utilice una extensidn el_ctrica de tres alambres con una clavija aternzada de tres terminales que pueda enchufarse
en un tomacorriente de tres orificios.AsegL_resede que su
extensi6n el6ctricaest_ en buenas condiciones. Si utiliza una extensi6n, compruebe que sea de la capacidad de eordente que
requiere su equipo. Las productisfactory tested to ensure prop- er operation and performance.
Procedimiento inicial de preparacibn No se requiere un procedimiento inicialde preparacibn. Este producto ha sido probado an la f_.brica para asegurar su operaci6n y desempedo adecuados.
Plug
14
Page 17
Procedimientos de operaci6n
Procedimiento diario de arranque
(_Ponga el Auto-On/Often la posici6n de
apagado (Off).
_Compruebe visualmente qua compresor no tenga
dafios ni obstrucciones.
(_)Cierre la v&lvula de drenado. (_Revise el nivel de aceite de la bomba.
Enchufe la manguera de aire al conector de acoplamiento rdpido de la unidad del regulador. El
collarin del conector de acoplamiento r#.pidosaltar_, para adelante, sujetando el enchufe y efectuando un
sello entre el conector y el enchufe. Para desconectar
la manguera de aire, empuje hacia atrds el collarfn del
conector de acoplamiento rdpido.
(_Enchufe el cable de corriente en un tomacorriente
apropiado.
interruptor
el
@Mueva el interruptor Auto-OniOffa la posici6n de
encendido (Auto-On); el compresor deberd arrancar, acumulando presi6n de aire en el tanque hasta Ilegar
a la presi6n de apagado, momento en el cual se apagard de manera automdtica.
(_)Ajuste el regulador a la presi6n de aire recomendada
para su aplicaci6n, cercior_.ndose de que est_ dentro de las normas de segufidad para Ilevar a cabo la tarea. En el caso de herramientas neum&ticas, el manual del fabricante debe tener recomendaciones
sobre su presi6n de operaci6n.
Nora: Ahora el compresor de aire est,. listo para ser
usado. Los siguientes accesorios de inflado y limpieza,
los cuales vienen con esta unidad, solo se deben
operar a una presi6n mdxima de 20-30 PSI: soplete
(y su adaptador), boquilla c6nica, agujas de inflado.
Procedimiento diario de apagado
1. Ponga el interrupter en la posici6n de apagado (Of/).
2. Desconecte el cable del tomacorriente.
3. Ponga en cero el regulador de presi6n de salida.
4. Desconecte las herramientas y accesofios. Siempre use protecci6n para ofdos y ojos al drenar el tanque.
Drene el tanque en un lugar adecuado; en casi todos los casos habra,presencia de condensaci6n en el
drenaje.
5. Abra la vdlvula de drenado permitiendo que escape el aire del tanque. Cuando haya salido del tanque todo el
aire, cierre la v_.lvula de drenado para evitar que le entre suciedad.
AI drenar el tanque utilice protecci6n para ofdos y ojos.
Drene el tanque en un lugar apropiado; en la mayorfa de
Lasocasiones al drenar saldr& condensaci6n.
Si no drena el tanque, en su interior quedar_, agua que Io corroer_ y debilitar_., Io cual puede provocar su ruptura.
Siempre drene el tanque diariamente o despu_s de cada
use.
15
Page 18
Mantenimiento
NOTA: Cualquier procedimiento de servicio que no este cubierto en el prograrna de mantenimiento que sigue deberd
ser efectuado por personal de servicio calificado.
Antes de cada Tras las
uso o diaria- primeras Cada
Puntos a revisar o ¢ambiar mente 10 horas 100 horas
Revisar la va.lvula de seguridad del tanque X Reviser visualmente el aspecto general de la unidad X Revisar el nivel de aceite X Cambiar el aceite X X
Revisar el filtro de aceite (con mayor frecuencia si se trabaja en ambientes polvosos o hSmedos) X
Drene el tanque (cada vez que sea usado o diariamente) X
A fin de asegurar una operaciSn eficiente y una larga vida del compresor, debe seguirse un programa de
mantenimiento de rutina. El siguiente programa de mantenimiento est,. enfocado al consumidor cuyo
compresor es usado en un medio ambiente normal y con
una periodicidad diaria. De ser necesario, el programase debe modificar pare adecuarlo alas condiciones bajo las
cuales se usar_,su compresor. Los compresores em pleados en medios ambientes muy sucios u hostiles
requerir_.n mantenimiento m_.sfrecuente.
Cambio de aceite El procedimiento pare cambiar el aceite de la compresora es el siguiente:
1. Apague el eompresory desenchufe el cable de
corriente.
2. Si el eompresorha estado en operaci6n, permitaque
se enfrie.
3. Abra la v&lvulade drenado para vaciar el aire del
tanque.
4. Cierre la v&lvulade drenado.
5. Quite el tapSn de [lenadode aceite que se eneuentra on la bomba.
6. Quite el visor con una Ilave de tuercas o de cubo. Deje que drene el aeeite on un recipienteadecuado y
deseche este contenedor de manera apropiada. Tel vez haya que inclinerel compresor ligeramente hacia adelante para que salga todoel aceite.
Antes de dar mantenimiento al equipo, se le debe apagar
y desconectar del tomacorriente, asf como purger el aire
del tanque y permitir que la unidad se enfrfe. Las partes en movimiento, las fuentes electricas, el aire comprimido
y las superficies calientes pueden provocar lesiones.
7. Vuelva a colocar el visor. NOTA: apriete el visor a un par do apriete de 10 a 12 libras-pulgacla. Revise
tambi_n le colocacion del empaque entre el visor y el
c_,rterdel compresor.
8. Llene lentamente la bomba del compresor con aceite pare compresor de aire, como aceite SAE-30 no
detergente (API CG/CD de trabajo pesado) hasta que Ilegue al centro del c(rculo rojo del visor. En
condiciones de invierno extremas use aceite SAE-10.
Almacenamiento
Pare almacenar el compresor, asegL_resede hacer Io siguiente:
1. Lleve a cabo el programa de mantenimiento de rutina.
2. Apague la unidad y desconecte del tomacorriente la clavija.
3. Quite de1compresor las mangueras, accesorios y herramientas de aire.
16
4. Abra la v_Jvula de drenado para drenar el aire del tanque.
5. Cierre la v_.lvula de drenado.
6. Guarde el compresor en un lugar limpio y seco.
Page 19
Diagnbstico y correccibn de fallas
Antes de dar mantenimiento al equipo, se le debe apagar y desconectar del tomacorriente, asi come purgar el aire del tanque y permitir que la unidad se enfr{e. Las partes en
movimiento, las fuentes el6ctricas, el aire comprLmido y las superficies ca[ientes pueden provoear lesiones.
PROBLEMA POSIBLE CORRECCION Fuga de aire en ta valvula do Una v_.lvula de retenci6n defectuosa provoea una fuga de aire constante en la
retenci6n o en la v_.lvu]a de v_lvula de alivio cuando est_ apagado el compresor teniendo presi6n de aire.
alivio. Drene el tanque y quite y limpie o cambie ]a valvula de retenci6n.
Fugas de aire entre la cabeza Compruebe el apriete de los pernos de la cabeza. Si contin=]a la fuga, Ilame a
y el cilindro, un t6cnico de servicio.
Fuga de aire en la va.lvula Opere manualmente la v_.lvula do seguridad tirando del anillo. Si el tanque contin6a de seguridad, teniendo una fuga estando la v_.lvula en posici6n cerrada, 6sta deber_,ser cambiada.
La presi6n indicadaen el man6metro de preei6n
Presi6n excesiva Apague el interruptor de encendido. Si la unidad no se apaga, descon_ctela del on el tanque, tomacorriente y comun[quese con un tecnico de servicio.
El motor no arranca. Compruebe que el cable de corriente esta enchufado y que el interruptor est&
Humedad excesiva en el aire de salida.
Si al usar un accesorio hay una ca[da excesiva de presion, cambie el regulador, regulada cae al usar un accesodo.
Ajuste la presi6n regulada bajo condiciones de flujo (mientras se utiliza un accesorio). Es normal que el man6metro indique una caida de presi6n
minima al comenzar a utilizar la herramienta.
encendido. Compruebe que el fusible de la caja de circuitos sea de la capacidad adecuada. Si se ha disparado, restabl6zcalo y rearranque la unidad. Si el fusible so
dispara con frecuencia, revise la vaivula de retenci6no Ilame a un t_cnicode servicio.
Saque el agua del tanque dren_.ndolo despu6s de cada vez que se use. En los medios ambientes de alta humedad habr_, un exceso de condensaci6n; instale
filtros de agua en su I_neade aire.
La condensaci6n no es provocada pot una falla en el compresor. Compruebe que la
salida de aire del compresor sea mayor que el consumo de aire de su herramienta.
Fugas do aire en el cuerpo o la soldadura del tanque.
Nunca taladre, suelde o modifique de ninguna manera el tanque, pues se debilitar_.. El tanque podria romperse o explotar. El tanque no puede ser
reparado. Ya no utilice el eompresor de aire.
17
Page 20
Your Home
For repair - in your home - of all major brand appliances,
lawn and garden equipment, or heating and cooling systems,
no matter who made it, no matter who sold it!
For the replacement parts, accessories and
owner's manuals that you need to do-it-yourself.
For Sears professional installation of home appliances
and items like garage door openers and water heaters.
1-800-4-MY-HOME ® (1-800-469-4663)
Call anytime, clay or night (U.S.A. and Canada)
www.sears.com www.sears.ca
Our Home
For repair of carry-in items like vacuums, lawn equipment,
and electronics, call or go on-line for the location of your nearest
Sears Parts & Repair Center.
1-800-488-1222
Call anytime, day or night (U.S.A. only)
www,sears.com
To purchase a protection agreement on a product serviced by Sears:
1-800-827-6655 (U.S.A.) 1-800-361-6665 (Canada)
Para pedir servicio de reparaci6n
a domicilio, y para ordenar piezas:
1-888-SU-HOGAR s"
(1-888-784-6427)
Au Canada pour service en fran_ais:
1-800-LE-FOYER
(1-800-553-6937)
www.sears.ca
SEARS
® Registered Trademark/TM Trademark/`" Service Mark of Sears, Roebuck _md Co. ® Marca Registradei Marca de F_b_cei Marca de Servicio de Sears, Roebuck and Co.
Marque de commerce/ Marque ddposde de Sears, Roebuck and Co. © Sears, Roebuck and Co.
Loading...