Craftsman 919195412 Owner’s Manual

Owner's Manual
I CRRFTgMRNI
Oil Lubricated
Single Stage Horizontal Portable
AiR COMPRESSOR
Model No.
919.195412
= Operation = Maintenance
= Troubleshooting = Repair Parts
CAUTION; Read the Safety Guidelines and All Instructions Carefully Before Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
1000003598 7/16/o7
WARRANTY ................................................ 2
SPECiFiCATiON CHART ...................................... 3
SAFETY GUiDELiNES ...................................... 3-9
GLOSSARY ............................................... 10
ACCESSORIES ............................................ 10
DUTY CYCLE .............................................. 10
ASSEMBLY ............................................ 11-12
iNSTALLATiON ......................................... 13-14
OPERATION ............................................ 15-17
MAINTENANCE ......................................... 18-20
SERVICE AND ADJUSTMENTS ............................ 21-23
STORAGE ................................................ 23
TROUBLESHOOTING GUIDE .............................. 24-27
REPAIR PARTS ......................................... 28-31
ESPAI_OL .............................................. 32-57
NOTES .................................................. 58
REPAIR PROTECTION AGREEMENTS ......................... 59
HOW TO ORDER REPAIR PARTS ...................... Back Cover
ONE YEAR FULL WARRANTY
Ifthis product fails due to a defect in material or workmanship within one year
from the date of purchase, Sears will at its option repair or replace it free of charge. Contact Sears at 1-800-4-MY-HOME ®to arrange for repair, or return it
to the place of purchase for replacement.
Ifthis product is used for commercial or rental purposes, this warranty applies
for only ninety days from the date of purchase. This warranty gives you specific legal rights and you may have other rights
which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179
1000003598 2-ENG
Model No. 919.1954t2 Running HP "1.8
Bore 2.875" (73.0 mm) Stroke 2.0" (50.8 mm)
Voltage-Single Phase 120/240 Minimum Branch Circuit Requirement 15 amps
Fuse Type Time Delay Air Tank Capacity 25 gallons (94.6 L)
Approximate Cut-in Pressure 120 PSi Approximate Cut-out Pressure 150 PSi
SCFM @ 40 PSIG *7.4 SCFM @ 90 PSIG *5.8
* Tested per ISO 1217 Refer to Glossary for abbreviations.
This manual contains information that is important for you to know and under- stand. This information relates to protecting YOUR SAFETY and PREVENTING
EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
_ Indicates an
imminently
hazardous situation which, if not
avoided, will result in death or serious in'u_.
_ Indicates a
potentialmy hazardous situation which, if not avoided, could result in death or
serious in'u_.
_:_ Indicates a
potentially
hazardous situation which, if not
avoided, _ result in minor or moderate injury.
_Used without the
safety alert symbol
indicates a potentially hazardous situation which, if not avoided, may
result in l_#perty damag#_.
_Some dust created by power sanding, sawing, grinding,
drilling, and other construction activities contains chemicals
known to the State of California to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:
lead from lead-based paints
crystalline silica from bricks and cement and other masonry products
® arsenic and chromium from chemically-treated lumber Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, always wear OSNA/MSNA/NIOSN approved, properly fitting face mask or respirator
when using such tools. When using air tools, basic safety precautions should always be followed to
reduce the risk of of personal injury.
3-ENG 1000003598
_This product contains chemicals, including lead, known to or other reproductive harm. Wash hands after handling.
operation and maintenance instructions.
the State of California to cause cancer, and birth defects
Do not operate this unit until you read and _A understand this instruction manual for safety,
SAVE THESE iNSTRUCTiONS
___ RISK OF EXPLOS,ON OR FiRE
What can happen
It is normal for electrical contacts within the motor and pressure
switch to spark.
Ifelectrical sparks from compressor
come into contact with flammable vapors, they may ignite, causing fire
or explosion.
Restricting any of the compressor ventilation openings will cause seri-
ous overheating and could cause fire.
Unattended operation of this prod- uct could result in personal injury
or property damage. To reduce the risk of fire, do not allow the com-
pressor to operate unattended.
Always operate the compressor in a
If spraying flammable materials,
Store flammable materials in a
Never place objects against or on
Operate compressor in an open
Operate compressor in a clean, dry
Always remain in attendance with
Always turn off and unplug unit
How to prevent it
well ventilated area free of combus- tible materials, gasoline, or solvent vapors.
locate compressor at least 20 feet (6.1 m) away from spray area. An
additional length of air hose may be required.
secure location away from com- pressor.
top of compressor.
area at least 12" (30.5 cm) away from any wall or obstruction that would restrict the flow of fresh air to
the ventilation openings.
well ventilated area. Do not operate unit indoors or in any confined area.
the product when it is operating. when not in use.
1000003598 4-ENG
__ RISK TO BREATHING (ASPHYXiATiON)
What can happen How to prevent it
The compressed air directly from Air obtained directly from the com- your compressor is not safe for presser should never be used to
breathing. The air stream may con- supply air for human consumption. tain carbon monoxide, toxic vapors, Inorder to use air produced by this
or solid particles from the air tank. compressor for breathing, suitable Breathing these contaminants can filters and in-line safety equipment
cause serious injury or death, must be properly installed. In-line
filters and safety equipment used in conjunction with the compressor
must be capable d treating air to all applicable local and federal codes
prior to human consumption.
Sprayed materials such as paint, Work in an area with good cross paint solvents, paint remover, insec- ventilation. Read and follow the
ticides, weed killers, may contain safety instructions provided on the harmful vapors and poisons, label or safety data sheets for the
materials you are spraying. Always use certified safety equipment:
OSHA!MSHA!NIOSH respiratory protection designed for use with
your specific application.
[__ RISK OF SERIOUS iNJURY OR PROPERTY DAMAGE
WHEN TRANSPORTING COMPRESSOR
Oil can leak or spill and could result in fire or breathing hazard;
serious injury or death can result. oil leaks will damage carpet, paint
or other surfaces in vehicles or trailers.
Always place compressor on a protective mat when transport-
ing to protect against damage to vehicle from leaks. Remove com-
pressor from vehicle immediately upon arrival at your destination.
,* |
__ RISK OF BURSTING
Air Tank: The air tank on your Air Compressor is designed and may be UM coded
[for units with air tanks greater than 6" (152.4 mm) diameter] according to ASME
Section VIII, Div. 1 rules. All pressure vessels should be inspected once every two years. To find your state pressure vessels inspector, look under the Division of Labor
and Industries in the government section of a phone book. The following conditions could lead to a weakening of the air tank, and result in a
violent air tank explosion:
5-ENG 1000003598
What can happen How to prevent it
Failure to properly drain condensed Drain air tank daily or after each water from air tank, causing rust use. If air tank develops a leak,
and thinning of the steel air tank. replace it immediately with a new air
tank or replace the entire compres- sor.
Modifications or attempted repairs Never drill into, weld, or make any to the air tank. modifications to the air tank or its
attachments. Never attempt to repair a damaged or leaking air
tank. Replace with a new air tank.
Unauthorized modifications to the The air tank is designed to with- safety valve or any other compo- stand specific operating pressures.
nents which control air tank pres- Never make adjustments or parts sure. substitutions to alter the factory set
operating pressures.
Attachments & accessories:
Exceeding the pressure rating of air tools, spray guns, air operated
accessories, tires, and other inflata- bles can cause them to explode or
fly apart, and could result in serious injury.
o
Follow the equipment manufactur- ers recommendation and never
exceed the maximum allowable pressure rating of attachments.
Never use compressor to inflate small low pressure objects such as
children's toys, footballs, basket- balls, etc.
Tires:
Over inflation of tires could result in serious injury and property damage.
Use a tire pressure gauge to check the tires pressure before each use
and while inflating tires; see the tire sidewall for the correct tire pressure.
NOTE: Air tanks, compressors and simi- lar equipment used to inflate tires can fill
small tires similarto these very rapidly. Adjust pressure regulator on air supply to
no more than the rating of the tire pres- sure. Add air insmall increments and
frequently use the tire gauge to prevent over inflation.
[__ RiSK OF ELECTRICAL SHOCK
What can happen How to prevent it
= Your air compressor is powered by Never operate the compressor
electricity. Like any other electrically outdoors when it is raining or in wet powered device, if it is not used conditions.
properly it may cause electric Never operate compressor with shock, protective covers removed or
damaged.
1000003598 6-ENG
Repairs attempted by unqualified personnel can result in serious
injury or death by electrocution.
Electrical Grounding: Failure to provide adequate grounding to
this product could result in serious injury or death from electrocution.
Refer to "Grounding Instructions" paragraph in the Installation section.
__ RISK FROM FLYING OBJECTS
Any electrical wiring or repairs required on this product should be
performed by authorized service center personnel in accordance with
national and local electrical codes. Make certain that the electrical
circuit to which the compressor is connected provides proper
electrical grounding, correct voltage and adequate fuse protection.
What can happen
= Always wear certified safety equip-
The compressed air stream can cause soft tissue damage to
exposed skin and can propel dirt, chips, loose particles, and small
objects at high speed, resulting in property damage or personal injury.
i _ i m D
Now to prevent it
ment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields
when using the compressor. Never point any nozzle or sprayer
toward any part of the body or at other people or animals. Always turn the compressor off and bleed pressure from the air
hose and air tank before attempt- ing maintenance, attaching tools or
accessories.
RISKOFNOTSURFACES
What can happen
Touching exposed metal such as the compressor head, engine head,
engine exhaust or outlet tubes, can result in serious burns.
Now to prevent it
Never touch any exposed metal parts on compressor during or
immediately after operation. Compressor will remain hot for
several minutes after operation. Do not reach around protective
shrouds or attempt maintenance until unit has been allowed to cool.
7-ENG 1000003598
_[_ _ RiSK FROM MOVING PARTS
What can happen
Moving parts such as the pulley, fly- wheel, and belt can cause serious
injuw if they come into contact with you or your clothing.
Now to prevent it
Never operate the compressor with guards or covers which are dam-
aged or removed. Keep your hair, clothing, and gloves
away from moving parts. Loose clothes, jewelry, or long hair can be
caught in moving parts.
o
Air vents may cover moving parts and should be avoided as well.
Attempting to operate compressor Any repairs required on this product with damaged or missing parts or should be performed by authorized
attempting to repair compressor service center personnel. with protective shrouds removed
can expose you to moving parts and can result in serious injuw.
[__ RISK OF UNSAFE OPERATION
What can happen Now to prevent it
Unsafe operation of your air com- Review and understand all instruc- presser could lead to serious injuw tions and warnings in this manual. or death to you or others. Become familiar with the operation
and controls of the air compressor.
Keep operating area clear of all per- sons, pets, and obstacles.
Keep children away from the air compressor at all times.
Do not operate the product when fatigued or under the influence of
alcohol or drugs. Stay alert at all times.
Never defeat the safety features of this product.
Equip area of operation with a fire extinguisher.
Do not operate machine with miss- ing, broken, or unauthorized parts.
1000003598 8-ENG
[__ RiSK OF iNJURY FROM LiFTiNG
What can happen
Serious injury can result from attempting to lift too heavy an
object.
= D
How to prevent it
The compressor is too heavy to be lifted by one person. Obtain assis-
tance from others before lifting.
RiSK FROM NOISE
Under some conditions and dura- Always wear certified safety equip- tion of use, noise from this product merit: ANSi $12.6 ($3.19) hearing
What can happen How to prevent it
may contribute to hearing loss. protection.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
9-ENG 1000003598
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute. SCFM: Standard cubic feet per min-
ute; a unit of measure of air delivery. PSmG: Pounds per square inch gauge;
a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified independent safety laboratories and
meet the applicable Standards for Safety.
Cut-in Pressure: While the motor
low level the motor will restart auto- matically. The low pressure at which
the motor automatically restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air com- pressor is turned on and begins to
run, air pressure in the air tank begins to build. It builds to a certain high
pressure before the motor automati- cally shuts off, protecting your air tank
from pressure higher than its capacity. The high pressure at which the motor
shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying elec-
tricity from electrical panel to outlet.
is off, air tank pressure drops as you continue to use your accessory. When
the tank pressure drops to a certain
This unit is capable of powering the following Accessories. The accessories are available through the current Power and Hand Tool Catalog or full-line Sears
stores. Accessories
in Line Filter Tire Air Chuck
Quick Connector Sets (various sizes)
Air Pressure Regulators
Air Hose:l/4" (6.4 mm), 3/8" (9.5 mm) or 1/2" (12.7 mm) inside
diameter in various lengths Refer to the selection chart located on the unit to select the tools this unit
is capable of powering.
Oil Fog Lubricators
This air compressor pump is capable of running continuously. However,
to prolong the life of your air com- pressor, it is recommended that a
50%-75% average duty cycle be
1000003598 10-ENG
maintained; that is, the air compres- sor pump should not run more than
30-45 minutes in any given hour.
CONTENTS OF CARTON 1 - Air Compressor
2- Wheels 2 - Shoulder Bolts, 3/8-16
2 - Hex Nuts, 3/8-16 1- Handle
1 - Handle Grip 2 - Cap Screws
2 - 1/4-20 Hex Nuts 2 - Retainer Clips
2 - Flat Washers 2 - Rubber Bumpers
2 - Screws, 1/4-20 x 3/4" (19 mm) TOOLS REQUIRED FOR
ASSEMBLY
1 - 9/16" (14 mm) socket or open
end wrench
1 - 1/2" (13 mm) socket or open end
wrench
UNPACKING Remove unit from carton and discard all packaging. NOTE: Save all parts
bags. TO INSTALL HANDLE
_The wheels and
handle do not
provide adequate clearance,
stability, or support for pulling the unit up and down stairs or steps.
The unit must be lifted or pushed up a ramp. Do not lift the unit by the
manifold assembly; the unit could be damaged.
1. To make installation easier, sub- merge handle grip into warm soapy water. Remove handle grip
from soapy water and slide onto handle.
2. Insert the open ends of the handle under the saddle. Before
attaching handle, you may have to pull the open ends of the han-
dle apart so they fit tightly against the side of the saddle. Looking in
from the open end of the saddle, position the handle toward the
two bent tabs, on the inside walls of the saddle.
3,
Slowly push the open ends of the handle onto both tabs at the
same time. Continue pushing the handle into the saddle until the
holes on the side of the saddle and handle are in line.
4,
Guide the straight end of each retaining clip through the saddle
hole and both handle holes.
11-ENG 1000003598
5. Rotate each retaining clip clock- wise and press down until it snaps into place over the handle.
6, If the handle has excessive
movement, it is improperly installed. Check the following.
A. Are both tabs inside the
handle (Step #3)?
B. Does each clip pass through
both the saddle and handle (Step #4)?
TO ASSEMBLE WHEELS
It will be necessary
to brace or support
one side of the air compressor when installing the wheels because the
compressor will have a tendency to tip.
1. Attach wheels with shoulder bolts and nuts as shown.
2. Tighten securely. NOTE: The air compressor will sit level if the
wheels are properly installed.
The wheels and handle do not
provide adequate clearance, stability or support for pulling the unit up and
down stairs or steps. The unit must be lifted, or pushed up a ramp.
ASSEMBLE RUBBER FEET
1. Attach rubber feet with the screws, washers and nuts pro- vided as shown in figure below.
2. Tighten securely. Nut
Wheel
Shoulder
?_?-= Rubber Foot
"_-'- Screw
Bolt
OIL FOR PUMP _This compressor was
shipped with oil in the pump crankcase. Check oil before operating air compressor, see Check
Oil under Maintenance.
1000003598 12-ENG
LOCATION OF THE AiR COMPRESSOR
Locate the air compressor in a clean, dry, and well ventilated area.
Place on a solid surface to pre- vent rocking or tipping.
The air compressor should be located at least 12" (30.5 cm)
away from the wall or other obstructions that will interfere with the flow of air.
The air filter must be kept clear of obstructions which could reduce
air flow to the air compressor. The air compressor requires
fresh air flow for proper cool- ing. DO NOT ALLOW THE
COMPRESSOR TO GET WET.
GROUNDING INSTRUCTIONS
-- ELECTRICAL
SHOCK. in the event of a short circuit, grounding reduces the risk
of shock by providing an escape wire for the electric current. This
air compressor must be properly
grounded. The portable air compressor is
equipped with a cord having a ground- ing wire with an appropriate grounding
plug (see following illustrations). The plug must be used with an outlet that
has been installed and grounded in accordance with all local codes and
ordinances.
1. The cord set and plug with this unit contains a grounding pin.
This plug MUST be used with a grounded outlet.
iMPORTANT: The outlet being used must be installed and grounded in
accordance with all local codes and ordinances.
RISK OF
2,
Make sure the outlet being used has the same configuration as the
grounded plug. DO NOT USE AN
ADAPTER. See illustration.
Plug
Grounding Pin
Grounded Outlets
3. Inspect the plug and cord before each use. Do not use if there are
signs of damage.
4. Ifthese grounding instructions are
not completely understood, or if in
doubt as to whether the compres- sor is properly grounded, have the
installation checked by a qualified
electrician.
-- ELECTRICAL
RISK OF
SHOCK. iMPROPER GROUNDING CAN RESULT IN ELECTRICAL
SHOCK.
Do not modify the plug provided. If it does not fit the available outlet, a
correct outlet should be installed by
a qualified electrician.
Repairs to the cord set or plug MUST be made by a qualified
electrician.
EXTENSION CORDS Using extension cords is not
recommended. The use of extension cords will cause voltage to drop
resulting in power loss to the motor and overheating.
13-ENG 1000003598
Instead of using an extension cord, increase the working reach of the
air hose by attaching another length of hose to its end. Attach additional
lengths of hose as needed. If an extension cord must be used, be
sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3- slot receptacle that will accept the
plug on the product in good condition
no longer than 50 feet 12 gauge (AWG) or larger. (Wire
size increases as gauge number decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE 14 OR 16 AWG.)
VOLTAGE AND CIRCUIT
PROTECTION Refer to the specification chart for the
voltage and minimum branch circuit
requirements. _Risk of Unsafe
Operation. Certain
air compressors can be operated on a 15 amp circuit if the following conditions are met.
1. Voltage supply to circuit must comply with the National Electrical Code.
2. Circuit is not used to supply any other electrical needs.
3. Extension cords comply with specifications.
4. Circuit is equipped with a 15 amp circuit breaker or 15 amp time
delay fuse. NOTE: If compressor is connected to a circuit protect-
ed by fuses, use only time delay fuses. Time delay fuses should be
marked "D" in Canada and "T" in the US.
Ifany of the above conditions cannot
be met, or if operation of the compres- sor repeatedly causes interruption
of the power, it may be necessary to operate it from a 20 amp circuit. It is
not necessary to change the cord set.
120/240 DUAL VOLTAGE MOTOR
This model has a dual voltage motor,
120 and 240 volt. It is wired for 120
volt but can be converted to 240 volt operation. Instructions for connecting
the motor for operation at 240 volt can be found printed on the label attached
to the side of the motor.
When converting to
240V operation, the
attached three-prong 120V cord assembly must be replaced with a
three-pronged 240V cord assembly (K-0080) that can be purchased
through a Sears Service Center.
120 Volt Plug 240 Volt Plug
1000003598 14-ENG
KNOW YOUR AIR COMPRESSOR READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future ref-
erence.
On/Auto/Off
On/Auto/Off Switch: Turn this switch "On/Auto" to provide automatic power
to the pressure switch and "Off" to remove power at the end of each use. Pressure Switch: The pressure switch automatically starts the motor when
the air tank pressure drops below the factory set "cut-in" pressure. The pres-
sure switch stops the motor when the air tank pressure reaches the factory
set "cut-out" pressure. Safety Valve: If the pressure switch
does not shut off the air compressor at its "cut-out" pressure setting, the
safety valve will protect against high pressure by "popping out" at its fac-
tory set pressure (slightly higher than the pressure switch "cut-out" setting).
Outlet Pressure Gauge: The outlet pressure gauge indicates the air pres- sure available at the outlet side of the
regulator. This pressure is controlled by the regulator and is always less than or
equal to the tank pressure. Tank Pressure Gauge: The tank pres-
sure gauge indicates the reserve air pressure in the tank.
Regulator: Controls the air pressure
shown on the outlet pressure gauge.
Pull the knob out and turn clockwise
to increase pressure and counterclock- wise to decrease pressure. When the
desired pressure is reached push knob
in to lock in place. Universal Quick-Connect Body: The
universal quick-connect body accepts
the three most popular styles of quick- connect plugs: Industrial, automotive
(Tru-flate), and ARC. One hand push- to-connect operation makes connec-
tions simple and easy.
Drain Valve: The
drain valve is
located at the base of the air
tank and is used to drain conden-
sation at the end of each use. Cooling System (not shown): This
compressor contains an advanced design cooling system. At the heart of
this cooling system is an engineered fan. It is perfectly normal for this fan to
blow air through the vent holes in large amounts. You know that the cooling system is working when air is being
expelled.
15- ENG
1000003598
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank pressure above that required at the air
outlet. Check Valve: When the air compres-
sor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air com-
pressor reaches "cut-out" pressure,
the check valve "closes", allowing air
pressure to remain inside the air tank.
Pressure
Release
To restart:
1. Place the On/Auto/Off
lever in the
"Off" pos-
tion.
2. Allow the motor to
cool.
3. Depress the red reset button on the motor.
4. Place the On/Auto/Off lever in the
"On/Auto" postion to restart the
motor.
HOW TO USE YOUR UNiT
Now to Stop 1 Set the On/Auto/Off switch to
"Off"
Before Starting
Check Valve
Pressure Release Valve: The pres- sure release valve, located on the side
of the pressure switch, is designed to automatically release compressed air
from the compressor head and the
outlet tube when the air compressor reaches "cut-out" pressure or is shut off. The pressure release valve allows
the motor to restart freely. When the
motor stops running, air will be heard escaping from this valve for a few
seconds. No air should be heard leaking when the motor is running or
after unit reaches "cut-out" pressure.
Air Intake Filter (not shown) This filter is designed to clean air coming
into the pump. This filter must always be clean and ventilation openings free
from obstructions. See Maintenance.
Motor: This motor has a manual ther- mal overload protectoE If the motor
overheats for any reason, the overload protector will shut off the motor. The
motor must be allowed to cool down before restarting.
_Do not operate this
unit until you read
and understand this instruction
manual for safety, operation and maintenance instructions.
Break-in Procedure
_Risk of Unsafe
Operation. Serious
damage may result if the following
break-in instructions are not closely
followed. This procedure is required before the
air compressor is put into service and when the check valve or a complete
compressor pump has been replaced.
1. Make sure the On/Auto/Off switch is in the "Off" position.
2. Check oil level in pump. See "Oil" paragraph in the Maintenance section for instructions.
NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the
quick connect.
3. Plug the power cord into the cor-
rect branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the Installation section of this manual.)
1000003598 16-ENG
4. Open the drain valve (counter- clockwise) fully to permit air to
escape and prevent air pressure build up in the air tank during the
break-in period.
5. Move the On/Auto/Off switch to
"On/Auto" position. The compres-
sor will start.
6. Run the compressor for 20 min- utes. Make sure the drain valve
is open and there is minimal air pressure build-up in tank.
7. After 20 minutes, close the drain valve by turning clockwise. The air receiver will fill to "cut-out" pres-
sure and the motor will stop.
The compressor is now ready for use. Before Each Start-Up
1. Set the On/Auto/Off switch to
"Off".
2. Pull regulator knob out, turn counterclockwise until it stops.
Push knob in to lock in place.
3. Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the
air outlet is equipped with a quick connect socket.
Risk of unsafe
_ --'-- operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.
_Risk of unsafe
operation.
Compressed air from the unit may contain water condensation and
oil mist. Do not spray unfiltered air at an item that could be damaged
by moisture. Some air tools and
accessories may require filtered air. Read the instructions for the air
tools and accessories.
How to Start
1. Set the On/Auto/Off switch to "On/Auto" and allow tank pressure
to build. Motor will stop when tank
pressure reaches "cut-out" pres-
sure.
2. Pull the regulator knob out and turn clockwise to increase pres-
sure. When the desired pressure is reached push knob in to lock in place.
If any unusual
""__ noise or vibration is noticed, stop the compressor immediately and have it checked by
a trained service technician. The compressor is ready for use.
_Risk of unsafe
operation. Do not
use damaged or worn accessories. _Risk of Bursting.
Too much air
pressure causes a hazardous risk of bursting. Check the manufacturer's
maximum pressure rating for air tools and accessories. The regulator
outlet pressure must never exceed the maximum pressure rating.
17-ENG 1000003598
CUSTOMER RESPONSiBiLITiES
Before Daily Every Every Every Every Yearly each or 8 40 100 160 use after hours hours hours hours
each use
Check Safety Valve Drain Tank
Oil Leaks Check Pump Oil
Change Pump Oil Unusual Noise and/
or Vibration
Air Filter o 1
Drive Belt-Condition Motor Pulley/Flywheel
alignment
Air compressor
pump intake and exhaust valves
Inspect air lines and *
fittings for leaks
Head Bolts - Check the torques of the head bolts after the first five hours of operation. 1- more frequent in dusty or humid conditions
Risk of Unsafe
' ""__ Operation. Unit
cycles automatically when power
is on. When servicing, you may be exposed to voltage sources,
compressed air, or moving parts. Before servicing unit unplug or
disconnect electrical supply to the air compressor, bleed tank
of pressure, and allow the air compressor to cool.
To ensure efficient operation and lon- ger life of the air compressor, a routine
maintenance schedule should be pre- pared and followed. The above routine
maintenance schedule is geared to an air compressor in a normal working
environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under
which your air compressor is used. The modifications will depend upon
1000003598 18-ENG
the hours of operation and the work-
ing environment. Compressors in an
extremely dirty and/or hostile environ-
ment will require a greater frequency of
all maintenance checks.
NOTE: See Operation section for the location of controls.
TO CHECK SAFETY VALVE
_Risk of Bursting. __ if the safety valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
_Risk from Flying
wear certified safety equipment: ANSI Z87.1 eye protection (CAN/
CSA Z94.3) with side shields.
Objects. Always
Loading...
+ 42 hidden pages