Craftsman 919751110, 919152361 Owner’s Manual

ModeJ No.
919o751110
919,152361
o Safety Guidelines o Assembmy
o Operation o Maintenance
o
CAUT|ON: Read the Safety Guidelines and All instructions CarefulIy Before Operating.
Sears, Roebuck and Co., Hoffman Estates, mL60179 U.S.A.
Visit our Oraftsman website: www, sears,com/craftsman
A10087 Rev, 0 1/25/05
WARRANTY ................................................ 2
SPECIFICATION CHART ..................................... 3
SAFETY GUIDELINES=DEFINITIONS ........................... 3
IMPORTANT SAFETY INSTRUCTIONS ........................ 3-8
GLOSSARY ................................................ 8
ACCESSORIES ............................................ 8
ASSEMBLY ................................................ 9
INSTALLATION .......................................... 9-10
OPERATION ........................................... t 1-14
MAINTENANCE ............................................ 14
STORAGE ................................................ t 4
TROUBLESHOOTING GUIDE ................................ 15
REPAIR PARTS ............................................ 16
ESPANOL .............................................. t7-30
HOW TO ORDER REPAIR PARTS ...................... back cover
FULL ONE YEAR WARRANTY AiR COMPRESSOR
If this CRAFTSMAN Air Compressor fails due to a defect in material or
workmanship within one year from the date of purchase, Sears will at
its option repair or replace it free of charge= Contact your nearest Sears
Service Center (1-800-4-MY-HOME ¢_)to arrange for repair, or return the Air Compressor to the place of purchase for replacement.
If this Air Compressor is used for commemia! or rental purposes, this warranty
applies for only ninety days from the date of purchase= This warranty gives you specific legal rights and you may have other rights
which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179
A10087 2= ENG
Model No, 919o751110
919o152361 Bore 1.875 Stroke 1.25
Voltage/Hertz/Phase 120/60/1 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay SCFM@ 30 psig 2.5
Maximum Pressure 125 PSI
This manual contains information that is important for you to know and understand, This information
relates to protecting YOUR SAFETY and PREVENTING EQBtPMENT PROBLEMS, To help you recognize this information, we use the symbols below, Please read the manual and pay attention to these sections,
Indicates an imminently hazardous
situation which, if not avoided, wHm result in death or serious in'u_AQl.
which, if not avoided, coumd result in
death or serious injury..
which, if not avoided, _ result in minor or moderate inulAQ_.
indicates a potentially hazardous
situation which, if not avoided, may
result in property damacLe.
Indicates a potentially hazardous situation
Used without the safety alert symbol
SAVE THESE iNSTRUCTiONS
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
_Some dust created by power sanding, sawing, grinding, drilling, and
of California) to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:
_' lead from lead-based paints _' crystalline silica from bricks and cement and other masonry products _' arsenic and chromium from chemically-treated lumber Your risk from these exposures varies, depending on how often you do this type of work.
To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear MSNA/NIOSN approved, properly fitting
face mask or respirator when using such tools. When using air tools, basic safety precautions should always be followed to reduce the
risk of personal injury.
other construction activities contains chemicals known (to the State
3= ENG A10087
Save these instructions
improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before
using this equipment.
m' J!!
WARNING: Risk of e×plosion or fire
What Could Happen
mtis normaR for eReetrical contacts within the motor to spark.
mfelectrical sparks from inflator come into contact with flammable vapors,
they may ignite, causing fire or explosion.
Restricting any of the inflator ventiRation openings will cause serious overheating
and could cause fire.
Unattended operation of this product could resuRt in personaR injury or property damage. To reduce the risk of fire, do not allow the inflator to operate
unattended.
How To Prevent mt
Always operate the inflator in a well ventilated area free of combustible
materiams, gasoline, or solvent vapors.
Store flammable materials in a secure beation away from inflator.
Never phce objects against or on top of inflator. Operate inflator in an open area at least 12 inches away from any
wall or obstruction that would restrict the flow of fresh air to the ventilation
openings. Operate inflator in a clean, dry well
ventilated area. Do not operate unit in any confined area.
ABways remain in attendance with the product when it is operating.
Always disconnect ebctricam power by moving on/off switch to the off position and unpRug the power cord.
A10087 4-ENG
_m
WARNING: Risk of Bursting _[_J I
What Coumd Happen
ATTACHMENTS & ACCESSORIES:
Exceeding the pressure rating of air operated accessories, tires, inflatable
balls, and other inflatables items can cause them to expmode or fly apart, and could result in serious injury.
Unattended tires, inflatable bans, inflatabBe toys, and other inflatable items can over inflate very quickly
sometimes in a matter of seconds and resumt in personam injury or property
damage.
iiiiiii_, D
WARNING: Risk from Fraying Objects
What Could Happen Now To Prevent It
The inflator air stream can cause soft tissue damage to exposed skin and
can propeB dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal
injury.
How To Prevent mt
Follow the equipment manufacturers recommendation and never exceed the
maximum allowable pressure rating of
attachments or inflatable items.
ABways remain in attendance when inflating tires, inflatabBe bans, inflatable toys, and other inflatabBe items. Be prepared to stop inflator when item is fully inflated, sometimes in a matter of
seconds.
Always wear ANSI Z87.1 approved safety gBasses with side shieMs when using the
inflator.
Never direct compressed air toward any part of the body or at other people or animals.
Always turn the inflator off before attempting maintenance, attaching tools,
or accessories.
5= ENG A10087
_D
WARNING: Risk of Emectricam Shock I_ I
what Could Happen
Your inflator is powered by electricity. Like any other electrically powered
device, If it is not used properly it may cause electric shock.
Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
Electrical Grounding: Failure to provide adequate grounding to this product could result in serious injury or death
from electrocution.
See grounding instructions.
WARNING: Risk to Breathing
How To Prevent it
Never operate the inflator outdoors when it is raining or in wet conditions.
Never operate inflator with protective
covers removed or damaged.
ABways replace damaged or worn eRectric cords before operating inflator.
Any electrical wiring or repairs required on this product should be performed by
authorized service center personnel in accordance with national and local
electrical codes.
Make certain that the eBectrical circuit
to which the inflator is connected provides proper eBectrical grounding, correct voltage, and adequate fuse protection.
When operating inflator outdoors use GFCI outlet.
What Could Happen How To Prevent It
The compressed air directly from your
inflator is not safe for breathing. The air
stream may contain carbon monoxide, toxic vapors, or solid particles from the tank. Breathing these contaminants
can cause serious injury or death.
A10087 6-ENG
Air obtained directly from the inflator should never be used to supply air for human consumption. In order to use air
produced by this inflator for breathing, suitable filters and in-line safety equipment must be property installed.
In=line filters and safety equipment used
in conjunction with the inflator must be capaMe of treating air to aH applicable
Iocamand federal codes prior to human consumption.
WARNING: Risk of Burns
What Could
Touching exposed metal such as the
inflator head or outlet tubes, can result
in serious burns.
WARNING: Risk from Moving Parts
Never touch any exposed metal parts on inflator during or immediately after operation, mnflator will remain hot for several minutes after operation.
Do not reach around protective shrouds or attempt maintenance until unit has
been allowed to cool.
What Could Happen
Moving parts such as the pulley, flywheel, and belt can cause serious injury if they come into contact with you, your clothing,
loose hair, or jewelery.
Attempting to operate inflator with damaged or missing parts or attempting to repair inflator with protective shrouds removed can expose you to moving parts and can result in serious injury.
WARNING: Risk of FaIHng
What Could Happen
An inflator can fan from a table, workbench, or roof causing damage to
the inflator and couBd result in serious injury or death to the operator.
How To Prevent It
Never operate the inflator with guards or covers which are damaged or
removed.
Any repairs required on this product should be performed by authorized
service center personnel
Now To Prevent It
Always operate inflator in a stabBe
secure position to prevent accidental
movement of the unit. Never operate
inflator on a roof or other elevated
position.
7- ENG A10087
iiiiiiii_,_,
WARNING: Risk of Unsafe Operation
What Could Happen
Unsafe operatien of your inflator ceu[d lead to serieus injury or death to you or ethers.
SAVE THESE INSTRUCTIONS
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute. SCFM: Standard cubic feet per
minute; a unit of measure of air delivery.
£SlG: Pounds per square inch gauge; a unit of measure of pressure.
How 3"oPrevent Jt
Review and understand all instructions
and warnings inthis manual.
Become familiar with the operatien and
controls of the inflator.
Keep operating area clear of all persons, pets,and obstacles.
Keep children away from the inflator at a[[
times.
Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at a[[ times.
Never defeat the safety features of this
product.
Equip area of eperation with a fire extinguisher.
Do not operate machine with missing, broken, or unautherized parts.
Code Certification: Products that bear one or more of the following
marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety=
Branch Circuit: Circuit carrying electricity from electrica! panel to
outlet.
This unit is capable of powering the following Accessories. Accessories included with your inflator:
inflation Needme: Used to inflate sport bails.
Extension Nozzle: Used to inflate small inflatable items such as air rafts
and beach balls.
High FBow inflator/Deflator adapter body with three nozzmes and sea[ ring: Used to inflate or deflate air mattresses, small boats, inflatable toys, and other inflatable items that use a large volume of low-pressure air.
A10087 8- ENG
Contents of Carton 1 - Inflator equipped with hose and
universal valve adapter
1 - Accessories Kit
1- Inflator Needle
To Remove inflator from Carton
1. Grasp handle and lift the inflator out of the carton.
2. Remove all packaging from inflator and discard.
1 - Extension Nozzle 1 - Nigh Flow Inflator/Defiator
adapter body with three nozzles and seal ring
NOW TO SET UP YOUR UNIT 1, The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a Location of the inflator Locate the inflator in a clean, dry
and well ventilated area. The inflator pump and housing are designed
to allow for proper cooling= The ventilation openings on the inflator
are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings=
grounded outlet.
IMPORTANT: The outlet being used must be installed and grounded in accordance with alI local codes and
ordinances.
2. Make sure the outlet being used
has the same configuration
as the grounded plug. DO
NOT USE AN ADAPTER, See illustration.
GROUNDmNG INSTRUCTIONS
Risk of Electrical Shock. In the
event of a short circuit, grounding reduces the risk of shock by
providing an escape wire for the electric current. This inflator must
be propermy grounded. The inflator is equipped with a cord
having a grounding wire with an appropriate grounding plug (see
following illustrations). The ptug must be used with an outlet that has been
installed and grounded in accordance with all local codes and ordinances.
Grounded
Outlets
Groundling Pin
3.
Inspect the plug and cord before
each use. Do not use if there are signs of damage.
4.
If these grounding instructions
are not completely understood, or if in doubt as to whether the
inflator is properly grounded, have the installation checked by
a qualified electrician.
9- ENG A10087
Risk of Electrical Shock, IMPROPER
GROUNDING CAN RESULT IN ELECTRICAL SHOCK, Do not modify the plug provided, If
it does not fit the avaiBable outlet, a correct outlet should be installed
by a qualified electrician, Repairs to the cord set or plug
MUST be made by a qualified
emectrician,
Extension Cords If an extension cord must be used, be
sure it is:
a 3-wire extension cord that has a 3-blade grounding ptug, and a
3-slot receptacle that will accept the ptug on the product
in good condition no longer than 50 feet
16 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 14, 12, 10, and 8 AWG may also be used.
Voltage and Circuit Protection
Refer to the specification chart for the voltage and minimum branch circuit requirements.
Certain inflators can be operated on a 15 amp circuit if the following
conditions are met.
1. Voitage supply through branch circuit is 15 amps.
2. Circuit is not used to supply any other electrical needs (lights, appliances, etc.).
3. Extension cords comply with specifications.
4. Circuit is equipped with a
15 amp circuit breaker or 15 amp time detay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay
fuses should be marked "D" in Canada and "T" in the US.
If any of the above conditions
cannot be met, or if operation of the compressor repeatedly causes
interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.