Owners’ Manual
AC Voltage and Current
Detector
Model 82147
CAUTION: Read,
understand and
follow Safety Rules
and Operating
Instructions in this
manual before using
this product.
ONE YEAR FULL WARRANTY
ONE YEAR FULL WARRANTY ON
CRAFTSMAN Detector
If this CRAFTSMAN Detector fails to
give complete satisfaction within one
year from the date of purchase,
RETURN IT TO THE NEAREST
SEARS STORE OR OTHER
CRAFTSMAN OUTLET IN THE
UNITED STATES, and Sears will
replace it, free of charge.
This warranty gives you specific legal
rights, and you may also have other
rights which vary from state to state.
Sears, Roebuck and Co., Dept.
817WA, Hoffman Estates, IL 60179
For Customer Assistance Call 9am 5pm (ET)
Monday through Friday 1-888-326-1006
WARNING: USE EXTREME CAUTION
IN THE USE OF THIS DEVICE.
Improper use of this device can result
in injury or death. Follow all
safeguards suggested in this manual
in addition to the normal safety
precautions used in working with
electrical circuits. DO NOT service
this device if you are not qualified to
do so.
UL LISTED
The UL mark does not indicate that this product has
been evaluated for the accuracy of its readings.
! Safety
! Operation
! Español
SAFETY PRECAUTIONS
1. Improper use of this meter can cause
damage, shock, injury or death. Read
and understand this manual before
use.
2. Secure any covers or battery doors
before use.
3. Inspect the condition of the meter for
any damage before use.
4. Remove the batteries from the meter if
the meter is to be stored for long
periods.
DESCRIPTION
1. Current Sensor and LED
2. Current Detector “ON” LED
3. Current Detector Sensitivity adjustment
4. Current/Voltage/OFF function selector
switch
5. Voltage Sensor and LED
6. Voltage Detector “ON” LED
7. Voltage Detector Sensitivity adjustment
8. Audible beeper
SPECIFICATIONS
Voltage detection 12V to 600VAC
Current sensitivity 200mA (0.2A) AC at
0.2”
Audible indication Beeper (Voltage &
Current)
Visible indication Flashing LED (Voltage
& Current)
Frequency range 50 to 500Hz
Operating Temperature 14 to 122°F (-
10°C to 50°C)
Operating Humidity < 80% RH
Altitude < 2000m
Power supply (4) LR44 batteries
Weight 2.1 oz. (60g)
Dimensions 7.6 x 1.2 x 0.9”
(192x31x24mm)
IEC 1010 Category III 600V
Indoor use
BATTERY REPLACEMENT
1. Turn power OFF
2. Slide the pocket clip off (as shown) to
access batteries.
3. Replace the four LR44 batteries. The
negative sides of the batteries face in
the same direction, as shown. The
positive sides of the batteries face in the
opposite direction.
-
+
OPERATING INSTRUCTIONS
WARNING: Risk of Electrocution.
Before use, always test the Detector on
a known live circuit to verify proper
operation
VOLTAGE DETECTION
1. Slide the Function switch to the Voltage
position.
2. The “VOLTAGE” LED will light. If the
LED is dim or does not light, replace
the batteries.
3. Set the Sensitivity adjustment to max.
4. If the detector begins to beep/flash,
slowly turn the sensitivity down until
the beep/flash stops.
5. Touch the detector voltage sensor to
the hot conductor or insert into the hot
side of the electrical outlet.
6. If AC voltage is present, the detector
light will flash and the audible beeper
will sound.
7. Adjust the sensitivity as needed to
zero-in and identify the live conductor.
WARNING: Risk of Electrocution.
Before use, always test the Detector on
a known live circuit to verify proper
operation
CURRENT DETECTION
NOTE: There must be a load on the
circuit (current flow) for the
current detection function to
work.
1. Slide the Function switch to the Current
position.
2. The “CURRENT” LED will light. If the
LED is dim or does not light, replace
the batteries.
3. Set the Sensitivity adjustment to the
max position
4. If detector begins to beep/flash, slowly
turn the sensitivity down until the
beep/flash stops.
5. Move the detector current sensor near
the current carrying conductor until the
current tip flashes and beeper sounds.
6. Slowly reduce the sensitivity and
reduce the distance between the
sensor and conductor to zero-in and
identify the conductor.