706.596680
6-Drawer Chest
Owners
706.596690
Craftsman 7-Drawer AXS TM Roll-Away
7-Drawer Roll-A-Way
Manual
Craftsman 6-Drawer AXS TM Chest
Section
1612
1613
1614
1615
1616
1617
1618
1623
1624
1625
Description
Chest Top and Facia
Drawer and Work Surface
Bottom Replacement
Top, Wiring Harness, Harness Grommet
Chest Top without Task Light
Task Light Replacement
Locking System
Lock Replacement
Striker Replacement
Drawer Front Replacement
CHEST TOP INSTALLATION AND REMOVAL
(With task light)
i CRAFTSMAN°i
CHEST TOP AND FACIA
PARTS REPLACEMENT
Chest Top with light
S
Tools Required:
3/8" Wrench
Chest Top Removal
• Disconnect power from unit.
• Remove enough drawers to reach the
top back inside of the unit. (See
Drawer installation and removal.)
• Push actuator rod to back of unit to
disconnect from back of lock. Move
actuator rod for access.
• Remove (4) screws holding top in
place.
• Lift top off of unit enough to reach the
wiring harness.
• Disconnect wiring harness from unit.
• Remove top from unit.
Press to
release
Chest Top Installation
• Connect wiring harness to top.
• Position top on unit.
• Attach using (4) screws.
• Make sure the back of the actuator
rod is inserted into the actuator rod
holder in the back of the unit.
• Push actuator rod toward back of unit
and line up with lock. Insert the
actuator rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
• Reconnect power to the unit.
Facia
Information Center
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
Disconnect
actuator rod
F1612 2
INFORMATION CENTER INSTALLATION
AND REMOVAL
Tools Required:
Screwdriver, Crosstip
Tape
Removal
• Disconnect power from the unit.
• Remove enough drawers to reach the
retaining screw under the information
center. (See removing and installing
drawers.)
• Loosen (do not remove) the retaining
screw under the information center.
• Pull the information center straight out
to remove.
Note: Tape wire to unit before
unplugging the information center. This
will prevent the wire from retracting into
the unit.
• Unplug the information center.
Tape wire in
place before
disconnectin(
Installation
• Plug in information center.
• Position information center in unit.
• Tighten retaining screw enough to
hold information center in place. Do
not overtighten.
• Reinstall drawers. (See Removing
and installing drawers.)
• Reconnect power to unit.
• Set information center as desired.
(See information center operation.)
Press to
release
FAClA INSTALLATION AND REMOVAL
Tools Required:
3/8" Wrench
drill
5/32" drill bit
Rivet gun
Pliers
To remove facia
• Remove enough drawers to reach the
top back inside of the chest.
• Remove lock. (See lock installation
and removal.)
• Remove chest top. See chest top
installation and removal.
• Carefully drill out (2) rivets holding
facia to chest.
• Remove facia.
To reinstall facia
• Position facia on unit. Make sure
connector is on top of chest.
• Attach using (2) rivets supplied.
• Reinstall lock, chest top, and drawers.
LOCK INSTALLATION AND REMOVAL
Rivet
Connector
Front
Loosen
retaining screw
LOCK INSTALLATION AND
REMOVAL
To remove lock
• Remove enough drawers to reach the
lock retaining clip behind the lock.
• Remove lock retaining clip. Pull lock
out to remove.
To reinstall lock
• Position lock in unit. Install retaining
clip to hold lock in place.
• Make sure the back of the actuator
rod is inserted into the actuator rod
holder in the back of the unit.
• Push actuator rod toward back of unit
and line up with lock. insert the
actuator rod into the back of the lock.
• Test lock operation.
• Reinstall drawers.
3 4
Lock
Actuator
rod
holder
'Lock
retaining
clip
CONNECTING POWER
• Ensure that the unit and power cord
are clean and dry.
• insert the round end of the power cord
connector into the jack in the back of
the unit.
• Plug the cord into an appropriate
electrical outlet.
Fuse block
Jack
Cord
REMOVING AND INSTALLING
DRAWERS:
• Empty the drawer.
• Fully extend the drawer.
Release
Lever Style - Lift or
lower (depending on the
slide) the release lever
on both sides, (this
allows the slides to ride
over the stops.) Pull out
to remove.
Tab Style - Depress the
release tabs on both
sides, (this allows the
slides to ride over the
stops.) Pull out to
remove.
To reinstall, carefully align the slides and
push the drawer into the unit until the
drawer stops.
INFORMATION CENTER
OPERATION
The information center is equipped with a
battery backup to maintain memory only.
The display will not function while power
is disconnected from the unit.
Outside temperature display requires
optional outside temperature sensor.
Display backlight
• Pressing _ turns the display
backlight on for 15 seconds.
Setting the current time
• Press and hold _ for at least
two seconds. (Second resets to zero
and hour begins to flash.)
• Press _ to set am/pm or 24 hour
mode as desired. Note: The am/pm
indicator is not shown in 24 hour
mode.
• Adjust hour using (_ and (_.
• Pressing _ toggles to next field.
Note: To toggle to minute without
changing hour, press _) then (_ then
• Adjust minute using (_ and (_.
• Press _ to toggle to next field.
• Repeat to adjust Month, Day, and
Year.
• Toggling past year exits set mode.
• Day of week is displayed according to
Month, Day, and Year.
Temperature Display
Pressing _ toggles inside and
outside temperature displays between
Celsius and Fahrenheit.
• Pressing _ toggles inside and
outside temperature displays between
ACT (Actual temperature)
MIN (Minimum recorded
temperature since last reset)
MAX (Maximum recorded
temperature since last reset)
• Press and hold _ for at least two
seconds to clear inside and outside
minimum and maximum recorded
temperatures.
• An audible beep will sound when
temperature is reset.
Setting the alarm
• Press and hold _ for at least
two seconds. (Second resets to zero
and hour begins to flash.)
• Adjust hour using (_ and (_).
• Pressing _ toggles to next field.
• Repeat to adjust minute.
• Toggling past minute exits set mode.
Turning alarm on or off
When the alarm is activated, the display
will show the indicator _,.
• Press _ to activate or deactivate
the alarm.
• Press _ to silence alarm when
ringing.
Time
\
• \\
oF_eoCP_
Clock Set
Alarm Set-_
(+)
D
Temp Inside
(-)
Timer function
• Press _ to enter timer mode.
• Press _ to start timer.
• Each time _ is pressed starts
or stops timer.
• Press and hold _ for at least
two seconds to reset timer to zero.
Count down timer function
• Press and hold _ for at least two
seconds.
• Display shows O0:O0:O0 and hour
begins to flash.
• Adjust hour using @ and @.
• Pressing @ toggles to next field.
• Repeat to adjust minute and second.
• Toggling past second exits set mode.
Note: To set timer to 24 hours, toggle
display to 00:00:0O.
• Press _ to start count down.
• Each time _ is pressed starts
or stops timer.
• Alarm sounds when timer reaches
0O:00:OO.
• Press any button to silence the alarm.
Clock
When in Timer or Count down timer
mode, press _ to display current
time. Press _ to return to timer
count down timer.
AM/PM
\ \
\ \
Date
Alarm
Activated
jTimer
Start/Stop
Clock
Alarm
Light
Temp outside
(Accessoryrequired)
or
5 6
I CRAFTSMAN°I
SLIDE REPLACEMENT
Tools Required:
Drill
5/32" Drill bit
Rivet gun
DRAWER AND WORK SURFACE
PARTS REPLACEMENT
Work Surface
Removal
• Remove drawer or work surface from
unit. (See drawer and work surface
installation and removal.)
• Carefully drill out rivet holding slide
drawer member to drawer or work
surface.
• Rotate front of slide drawer member
down and out.
• Pull slide forward to remove.
• Carefully drill out rivet holding slide
unit member in place.
• Pull slide unit member forward to
remove.
Back hanger
place
Installation
• Separate slide drawer member from
unit member. (See drawer and work
surface installation and removal.)
• install new slide unit member. (Install
back hanger first.)
• Rivet unit member in place as shown.
• install drawer member. (Install back
hanger first.)
• install rivet to hold slide drawer
member in place.
• Reinstall drawer or work surface into
unit. (See drawer and work surface
installation and removal.)
%,
Slide
Sears, Roebuck and Co., Hoffman Estates, IL 60179, USA
Drawer
Left side
Slide
Rivet
F1613 2
Hanger
pointed up
Drawer
DRAWER AND WORK SURFACE REPLACEMENT DRAWER FRONT INSTALLATION AND REMOVAL
Tools Required:
Drill
5/32" Drill bit
Rivet gun
Crosstip screwdriver
Removal
• Remove drawer or work surface from
unit. (See Drawer and Work surface
installation and removal.)
• Carefully drill out rivets holding slides
to drawer.
• Rotate front of slide down and out.
• Pull slide forward to remove.
Drawers only
• Remove striker. (See striker
replacement.)
• Remove drawer front. (See drawer
front replacement.)
Right side
Striker
\
Left side
Slide
Siide
Installation
• Install slides on new drawer or work
surface. (install back hangers first.)
• Install rivets to hold slides in place.
Drawers only
• Install striker. (See striker
replacement.)
• Install drawer front. (See drawer front
replacement.)
Drawers and work surface
• Install drawer or work surface in unit.
See drawer and work surface
installation and removal.
Hanger
pointed up
Drawer
front
o
Tools Required:
Crosstip screwdriver
Removal
• Remove retaining screw(s).
• Slide drawer front assembly as
indicated to unhook mounting tabs.
• Pull out to remove.
Installation
• Position drawer front on drawer
assembly.
• insert mounting tabs into notches on
drawer.
• Slide drawer front over to attach.
• install retaining screw(s) to hold
drawer front in place.
Mounting
tab
Notch
Retaining
screws
Bottom
drawer only
Drawers (4)inches
deep or more only
Rivet
d-
J ,
Drawer
3 4