Craftsman 580.325601 User Manual

Owner's Manual
®
o Safety o Assembly
o Operation
CAUTtON
Before using this product, read this
manual and follow all Safety Rules
and Operating Instructions.
Sears, Roebuck and Co., Hoffman Estates, _L 60179 U.S.A.
Visit our Craftsman website: www.craftsman.com
Part No. 197127GS Draft 1 (07/29/2005) 0 7
Antes de utilizar el producto, lea este
PRECAUCI6N
o Maintenance o Parts
o Espa_oN
WARRANTY .................................... 2
SAFETY RULES ............................... 3-4
FEATURES AND CONTROLS ...................... 5
ASSEMBLY ................................... 6-7
OPERATION ................................. 8-1 1
SPECIFICATIONS ............................... 12
MAINTENANCE .............................. 13-15
STORAGE ..................................... 16
TROUBLESHOOTING ............................ 17
SCHEMATIC DIAGRAM .......................... 18
WIRING DIAGRAM .............................. 19
REPLACEMENT PARTS ....................... 20-28
NOTES ....................................... 29
EMISSION CONTROL WARRANTY .............. 30-31
ESPAI_OL ................................... 32-51
HOW TO ORDER PARTS ................ BACK PAGE
LIMtTED WARRANTY FOR DELUXE PORTABLE GENERATORS
SEARS warrants to the original purchaser that the alternator and engine for its portable generator will be free from defects in materials or workmanship for the items and period set forth below from the date of original
purchase. This warranty is not transferable and applies only to portable generators driven by the Sears warranted engine.
CONSUMER* COMMERCIAL*
Alternator 2 years (2nd year parts only) 1 year
Engine 2 years (2nd year parts only) 1 year
* NOTE: For the purpose of this warranty "Consumer Use" means personal residential household and emergency use by original purchaser, not to be used as a primary source of power. "Commercial Use" means all other uses, including rental, construction, commercial, and income producing purposes. Once a generator has experienced commercial use, it shall thereafter be considered a commercial use generator for the purpose of this warranty.
During said warranty period, SEARS will, at its option, repair or replace any part which, upon examination by SEARS, is found to be defective under normal use and service**. Starting batteries are not warranted by
SEARS. All transportation costs under warranty, including return to the factory if necessary, are to be borne by the purchaser and prepaid by him. This warranty does not cover normal maintenance and service and does not
apply to a generator set, alternator or engine, or parts which have been subjected to improper or unauthorized installation or alteration, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair
or storage so as, in SEARS's judgment, to adversely affect its performance and reliability. ** NORMAL WEAR: As with all mechanical devices, engines need periodic parts service and replacement to
perform well. This warranty will not cover repair when normal use has exhausted the life of a part or engine.
THERE IS NO OTHER EXPRESS WARRANTY. SEARS HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW. THE DURATION OF ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD AS SPECIFIED IN THE EXPRESS WARRANTY. LIABILITY FOR
CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.
For service, see your nearest SEARS authorized warranty service facility. Warranty service can be performed only by a SEARS authorized service facility. This warranty will not apply to service at any other facility. At the time of requesting warranty service, evidence of original purchase date must be presented.
Sears, Roebuck and Co., Dept. DI817 WA, Hoffman Estates, IL 60179 U.S.A
@Sears Brands, LLC
Thisis the safety alert symbol, it is used to alert you to potential personal inju_' hazards.
Obey all safety messages that foltow this symbol to avoid possible injury or death.
,¢'_ I_Read this manuat carefully and become
.... familiar with your generator. Know its
applications, its limitations, and any hazards
involved.
The safety alert symbol (,&) is used with a signal word (DANGER, CAUTION, WARNING), a pictorial and/or a safety message to alert you to hazards.
DANGER indicates a hazard which, if not avoided, wil/ result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.
WARNING
The engine exhaust from this product contains chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
This generator does not meet U. S. Coast Guard
Regulation 33CFR=183and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard
approved generator could result in death, serious injury and/or property damage.
Hazard Symbols and Meanings
WARNING
Operate generator ONLY outdoors. Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).
WARNING
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate generator from electric utility.
Use a ground circuit fault interrupter (GFCi) in any damp or highly conductive area, such as metal decking or steel
work.
DO NOT touch bare wires or receptacles. DO NOT use generator with electrical cords which are
worn, frayed, bare or otherwise damaged.
DO NOT operate generator in the rain. DO NOT handle generator or electrical cords while
standing in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or service generator.
Electrocution Electrical Shock
Explosion
Fire
Toxic Fumes Hot Surface Kickback
WARNING
When starting engine, pull cord slowly until resistance is felt and then pul! rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in and turned on.
WARNING
WARNING
WHEN ADDING OR DRAINmNG FUEL
Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill or drain fuel tank outdoors. DO NOT overfill tank. Allow space for fuel expansion.
Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap and air cleaner are in place.
DO NOT crank engine with spark plug removed. If fuel spills, wait until it evaporates before starting
engine.
WHEN OPERATING EQUIPPv_ENT
Do not tip engine or equipment at angle which causes
fue! to spill.
DO NOT choke carburetor to stop engine. This generator is not for use in mobile equipment or
marine applications.
WHEN TRANSPORTING OR REPAIRING EQUIPMENT
Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WiTH FUEL IN TANK
Store away from furnaces, stoves, ,water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.
WARNING
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR + Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester. DO NOT check for spark with spark plug removed.
CAUTION
DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when
running at governed speed. DO NOT modify generator in any way.
CAUTION
See "Don't Overload Generator". Start generator and let engine stabilize before connecting
electrical loads. Connect electrical loads in OFF position, then turn ON
for operation. Turn electrical loads OFF and disconnect from generator
before stopping generator.
CAUTION
DO NOT touch hot surfaces.
Allow equipment to cool before touching.
The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
Keep at least 3 feet of clearance on all sides of generator
for adequate cooling, maintenance and servicing.
In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.You can order a spark arrester through your
authorized Sears service dealer.
Use generator only for intended uses. If you have questions about intended use, ask dealer or
contact Sears. Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
DO NOT insert any objects through cooling slots. If connected devices overheat, turn them off and
disconnect them from generator. Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
KNOW YOUR GENERATOR
Read the owner's manual and safety rules before operating your generator, Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
Choke Lever
Air Cleaner
Recoil Starter
Rocker Switch
(on engine shroud)
.J
.J
Circuit
Breakers (AC)
FuelTank
120/240 VAC,
30A Receptacle
Fuel Valve
(2) 120 VAC, 20A Duplex Receptacles
120 VomtAC, 20 Amp, Duplex Receptacles -- May be used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp LocHng Receptacle --
May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and
motor loads. Air Cleaner -- Protects engine by filtering dust and
debris out of intake air. Choke Lever -- Used when starting a cold engine. Circuit Breakers (AC) -- Push to reset circuit
breakers are provided to protect the generator against electrical overload.
Grounding Fastener
Spark Arrester Muffler
Fuel Tank -- Capacity of five (5) U.S. gallons. Fuel Valve -- Used to turn fuel on and off to engine.
Grounding Fastener -- If required, please consult a qualified electrician, electrical inspector, or local agency having jurisdiction.
Oil Fill -- Add engine oil here.
Recoil Starter -- Used to start the engine.
Rocker Sw{tch -- Set this switch to "On" before using
recoil starter. Set switch to "Off" to switch off engine. Spark Attester Muffler- Exhaust muffler lowers
engine noise and is equipped with a spark arrester screen.
YourCraftsmangeneratorrequiressomeassembly andisreadyforuseonlyafterithasbeenproperly
servicedwiththerecommendedoilandfuel. Ifyou haveanyproblemswith theassemMyof
your generator,pleasecallthegeneratorhelpline
at1-800-222-3136. IMPORTANT:Anyattempttoruntheenginebeforeit
hasbeenservicedwiththerecommendedoilwillresult inanenginefailure.
REMOVE GENERATOR FROM CARTON
1. Set the carton on a rigid flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from top to bottom.
4. Leave generator on carton to install wheel kit.
CARTON CONTENTS
Check all contents. If any parts are missing or damaged, call the generator helpline at 1-800-222-3136.
The main unit
Owner's manual
Engine oil
120/240 Volt, 30 Amp locking plug
Wheel Kit
ASSEMBLING THE WHEEL KIT
NOTE: Wheel kit is not intended for over=the=road use. You will need the following tools to install these
components:
1/2" or 13mm wrench
Socket wrench with a 1/2" or 13mm socket
Pliers Refer to imlustrationshown below and install the wheel
kit as fol!ows:
1. Tip generator so that engine end is up.
2. Slide axle through both mounting brackets.
3. Place a wheel on each side with air valve facing out.
4. Place a washer on axle and then place an e-ring in axle groove.
5. Install e-dng with pliers, squeezing from top of e- ring to bottom of axle.
6. Repeat step 3 through 5 to secure second wheel.
7. Tip generator so that engine side is down.
8. Line up holes in support leg with holes in generator frame.
9. Attach support leg using two short (M8 x 16mm) cap screws and two locking hex nuts. Tighten with
a 1/2" or 13mm socket and wrench.
10. On support leg end of generator, slide handle onto center of top of frame.
11. Attach handle using two long (M8 x 45mm) cap screws and two locking hex nuts. Tighten with a
1/2" or 13mm socket and wrench.
12. Return generator to normal operating position (resting on wheels and support leg).
13. Check that tires are inflated to value marked on tire or within 15 and 40 psi.
Handle Assembly,
Hex
Support Leg
Cap Screw
Hex Nut _
Whee_ Kit Assembly View
\
\,
Cap Screw
Axle
Wheel
Flat Washer
/
/
E=Ring
BEFORE STARTING THE
GENERATOR
To operate the generator you will need to first add engine oil and gasoline, as follows:
Add Engine Oim
NOTE: When adding oil to the engine crankcase, use only high quality detergent oil rated with API service classification SF, SG, SH, SJ or higher. DO NOT use special additives.
1. Choose a viscosity according to the table below:
STARTING TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE
* The use of multi-viscosity oils (5W-30, 10W-30, etc.) in temperatures above 40°F (4°C) will result in higher than normal oil consumption. When using a multi- viscosity oil, check oil more frequently.
** If using SAE 30 oil in temperatures below 40°F (4°C), it will result in hard starting and possible engine
bore damage due to inadequate lubrication.
NOTE: Synthetic oil meeting ILSAC GF-2, API certification mark and API service symbol with "SJ/CF
ENERGY CONSERVING" or higher, is an acceptable o11at all temperatures. Use of synthetic oil does not alter required oil change intervals.
2. Place generator on a level surface.
3. Clean area around yellow oil fill cap. Remove oil
fill cap.
4. Slowly fill engine with oil through oil fill opening
until oil level is to the point of overflowing.
5. Install yellow oil fill cap and finger tighten securely.
6. Check engine oil level before starting each time
thereafter. If oil level is below the point of overflowing, fill to proper level.
NOTE: Check oil often during engine break-in.
Add Fue_
WARNING
WHEN ADDING FUEL
Turn generator OFF and let it coo! at least 2 minutes
before removing fue! cap. Loosen cap slowly to relieve pressure in tank.
Fill fuel tank outdoors. DO NOT overfill tank. Allow space for fuel expansion.
Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
DO NOT light a cigarette or smoke.
NOTE: This gasoline engine is certified to operate on
gasoline. Exhaust Emission Control System: EM
(Engine Modifications).
1. Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane with equipment. DO NOT
use fuel which contains Methanol. DO NOT mix oil
with fuel.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill. Allow about 1.5" of tank
space for fuel expansion, as shown here.
Tank
\\\\\\\
4. Install fuel cap and wipe up any spilled fuel. CAUTmON! Alcohol-blended fuels (called gasohol,
ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. Drain the fuel tank, start the engine and let it run until the fuel lines
and carburetor are empty. Use fresh fuel next season. See "Storage" on page 16 for additional information.
NEVER use engine or carburetor cleaner products in
the fuel tank as permanent damage may occur.
HOW TO USE YOUR GENERATOR
if you have any problems operating your generator,
please call the generator helpline at 1o800o222o3136.
System Ground
The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).
Spec{amRequirements There may be Federal or State Occupational Safety
and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having
jurisdiction.
in some areas, generators are required to be registered with local utility companies.
if the generator is used at a construction site, there may be additional regulations which must be
observed.
Connecting to a BuHding's E_ectrica_ System
Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all appJicable laws and electrical codes.
Generator Location
Generator Clearance
WARNING
Operate generator ONLY outdoors. Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure, including the generator compartment of a
recreational vehicle (RV).
The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other
combustible materials. Leave at least 3 ft. (92 cm) all
around generator including overhead, for adequate
cooling, maintenance and servicing. Place generator in a well ventilated area, which will
allow for removal of deadly exhaust gas. DO NOT
place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a
confined area. Prevailing winds and air currents should be taken into consideration when positioning generator.
WARNING
When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
Use a ground circuit fault interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel
work.
DO NOT touch bare wires or receptacles. DO NOT use generator with electrical cords which are
worn, frayed, bare or otherwise damaged.
DO NOT operate generator in the rain. DO NOT handle generator or electrical cords while
standing in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or service generator.
Typical Generator Shown
Exhaust Port
Disconnect alJelectrical loads from the generator. Use
the foiJowing start instruction steps by numerical order:
1. Make sure unit is on a level surface. iMPORTANT: FaiJure to start and operate unit on a
leveJ surface wilJ cause the unit not to start or shut
down during operation.
2. Turn the fueJ vaJve to the "On" position.
+t/t_-
3. Place the choke Jever in the "Choke" position.
+
Set the rocker switch to "On" position.
-, Rocker Switch is shown in the
On position
WARNING
DO NOT touch hot surfaces.
Allow equipment to cool before touching. The generator must be at least 5 feet from structures having
combustible wails and/or other combustible materials. Keep at least 3 feet of clearance on all sides of generator
for adequate cooling, maintenance and servicing.
In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order+You can order a spark arrester through your
authorized Sears service dealer.
To Stop the Engine
1. UnpJug aJJeJectricaJ loads from generator paneJ receptacles. NEVER start or stop engine with electrical devices plugged in and turned on+
2+ Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
5+
Grasp the recoil handJe and puJJsJowJyuntiJslight resistance is felt. Then puJJrapidly to start engine.
WARNING
When starting engine, pull cord slowly until resistance is
felt and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in and turned on.
iMPORTANT: If engine floods, place choke Jever in
"Run" position and crank untiJ engine starts.
6. Move choke Jever to "Run" position a short distance at a time over several seconds in warm
weather or minutes in coJd weather. Let engine
run smoothly before each change. Operate with choke in "Run" position.
NOTE: Jfengine starts after 3 puJJsbut fails to run, or if unit shuts down during operation, make sure unit is
on a leveJ surface and check for proper oil JeveJin
crankcase. This unit may be equipped with a low oiJ protection device.
DO NOT stop engine by moving choke lever to "Choke"
I CAUTION
position. Backfire, fire or engine damage could occur.
3+ Move rocker switch to "Off' position.
1
4+ Move fuel vaJve to "Off' position.
Connecting Electrica_ Loads
DO NOT connect 240 Volt loads to 120 Volt receptacles.
DO NOT connect 3-phase Joads to generator.
DO NOT connect 50 Hz loads to generator.
Let engine stabilize and warm up for a few minutes after starting.
PJug in and turn on desired 120 and/or 240 Volt AC, singJe phase, 60 Hz eJectricaJ loads.
DO NOT OVERLOAD THE GENERATOR. See "Don't OverJoad Generator".
CAUTION
See "Don't Overload Generator". Start generator and let engine stabilize before connecting
electrical loads. Connect electrical loads in OFF position, then turn ON
for operation. Turn electrical loads OFF and disconnect from generator
before stopping generator.
CORD SETS AND RECEPTACLES
CAUTION
NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.
DO NOT overload the generator, See "Don't Overload Generator".
Use only high quality, well-insulated, extension cords
with the generator's 120 Volt electrical receptacles. Check the ratings of all extension cords before you
use them. Extension cord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most
electrical devices. Some devices, however, may not require this type of extension cord. Check the owner's
manuals of those devices for the manufacturer's recommendations.
Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible overheating of wires.
120 Volt AC, 20 Amp Duplex Receptacle
Each receptacle is protected against overload by a single 20 Amp push-to-reset circuit breaker. Use each receptacle to operate 120 Volt AC, single phase 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current.
1201240 Volt AC, 30 Amp Receptacle
This is a full capacity receptacle; it can supply the
1
generator's full rated output from this sole outlet. The outlet is protected by two 20 Amp push-to-reset
circuit breakers.
4-Wire Cord Set
_j_ Y (Hot) X (Hot)
NEMA L14-30 /_ Ground (Green)
A NEMA L14-30 plug is used with this 240 Volt
receptacle. Connect a suitable 4-wire cord set to the plug and to the desired load. The cord set should be rated for 250 Volt AC loads at 30 Amps (or greater).
10
DON'T OVERLOAD GENERATOR
Capacity
You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This
is the amount of power your generator must produce to keep your items running. See the table on the right.
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
Example:
Tool or Appliance Window Air
Conditioner
Refrigerator Dee£ Freezer
Television
Light (75 Watts)
Rated
_Runnin _ VVatts
1200
8OO 5OO 5OO
75
3075 Total
Running Watts
Total Rated (Running) Watts
Highest Additional Surge Watts Total Generator Output Required
Power Management
To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator. There should be nothing connected to the generator outlets before starting it's engine. The correct and safe way to manage generator power is to sequentially add loads
as follows:
1. With nothing connected to the generator, start the engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest load you have.
3. Permit the generator output to stabilize (engine runs smoothly and attached device operates
properly.
Additional Surge
1800
1600
5OO
1800 Highest
Surge Watts
= 3075 = 1800
= 4875
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.
Take special care to consider surge loads in generator
capacity, as described above.
Rated*
Too! or Appliance
Essentials Light Bulb - 75 watt
Deep Freezer Sump Pump
Refrigerator/Freezer- 18 Cu. Ft. Water Well Pump - 1/3 HP
Heating/Cooling Window AC - 10,000 BTU
Window Fan Furnace Fan Blower- 1/2 HP
Kitchen Microwave Oven - 1000 Watt Coffee Maker
Electric Stove - Single Element Hot Plate
Family Room DVD/CD Player VCR
Stereo Receiver Color Television - 27"
Personal Computer w/17" monitor
Other Security System
AM/FM C!ock Radio
Garage Door Opener - 1/2 HP Electric Water Heater - 40
Gallon D_Y/Job Site
Quartz Haloqen Work Light
Airless Sprayer - 1/3 HP
Reci rocatin Saw Electric Drill - 1/2 HP
Circular Saw - 7 1/4" Miter Saw - 10" Table Planer - 6"
Table Saw/Radial Arm Saw - 10"
Air Compressor - 1-1/2 HP
(Running) (Starting)
Watts
75
500 500
800 1200 800 1600
1000 2000
1200 1800
300 600
800 1300
1000 1500 1500 2500
100 100
45O
5OO
8OO
180 3OO
480 520
4000
1000
600 1200
960 960 1000 1000 1500 1500 1800 1800 1800 1800
2000 2000
2500 2500
*Wattages listed are approximate only.
appliance for actual wattage.
Additional
Surge
Watts
Check tool or
11
ENGINE TECHNICAL INFORMATION
This is a single cylinder, overhead valve(OHV), air cooled engine, it is a low emissions engine.
in the State of California, Model Series 200000
engines are certified by the California Air Resources
Board to meet emissions standards for 250 hours.
Such certification does not grant the purchaser, owner or operator of this engine any additional warranties with respect to the performance or operational life of
this engine. The engine is warranted solely according to the product and emmisions warranties stated
elsewhere in this manual.
Power Ratings
The power ratings for an individual engine model are initially developed by starting with SAE (Society of
Automotive Engineers) code J1940 (Small Engine
Power & Torque Rating Procedure) (Revision 2002-
05). Given both the wide array of products on which our engines are placed, and the variety of
environmental issues applicable to operating the equipement, it may be that the engine you have purchased will not develop the rated horsepower when
used in a peice of power equipment (actual "on-site" power). This difference is due to a variety of factors
including, but not limited to, the following: differences in altitude, temperature, barometric pressure, humidity, fuel, engine lubrication, maximum governed engine
speed, individual engine to engine variability, design of the particular peice of power equipment, the manner in
which the engine is operated, engine run-in to reduce friction and clean out of combustion chambers, adjustments to the valves and carburetor, and other
factors. The power ratings may also be adjusted based on comparisons to other similar engines
utilizedin similar applications, and will thereforenot necessarily match the values derived using the foregoing codes.
PRODUCT SPECIFICATIONS
Generator Specifications
Starting Wattage .............. 8600 Watts (8.6 kW)
Wattage ..................... 5600 Watts (5.6 kW)
AC Voltage ........................ 120/240 Volts
AC Current
at 240 Volts ........................ 23,3 Amps
at 120 Volts ........................ 46,6 Amps
Frequency ..................... 60 Hz at 3600 rpm
Phase ............................. Single Phase
Unit Weight ............................. 170 Ibs,
Engine Specifications
Horsepower ...................... 10 at 3600 rpm
Bore ............................ 3,12 in. (79mm)
Stroke .......................... 2.44 in. (62mm)
Displacement ................... 18.64 in. (305 cc)
Spark Plug
Type: .......... Champion RC12YC or Equivalent
Set Gap To: ................ 0.030inch (0.76mm)
Armature Air Gap: .................. 0,008-0,0!2 in.
(0,20-0,30ram)
Valve clearance withvalve springs installedand piston I/4 in.
(6 mm) past top dead center (check when engine is cold).
Intake ........................... 0,004-0,006 in.
(0,10-0,15 mm)
Exhaust .......................... 0,004-0,006 in.
(0,10-0,15 mm)
Fuel Capacity ...................... 5 U.S. gallons
Oil Capacity ................ 28 Ounces (.8 Liters)
Oil Type:
Above 40° F ........................ SAE 30
Below 40° F ............ SAE 5W-30 or 10W-30
12
OWNER'S RESPONSIBILITIES
Follow the hourly or calendar intervals, whichever occurs first. More frequent service is rec uired when operating in adverse conditions noted below.
MABNTENANCE SCHEDULE
FILL tN DATES AS YOU SERVICI= DATES
COMPLETE REGULAR SERVICE SERVICE DATES
Before Every 25 Hours Every 50 Hours Every 100
MAINTENANCE TASK Each Use or Year y or Year y Hours or Yearly
Check oil level X Clean debris X
Change engine oil X1 Service air cleaner X2
Service spark plug X Service spark arrester X
Clean cooting system X2 Prepare for storage If unit is to remain idle for longer than 30 days.
Change oit after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter. Change sooner when operating under dirty or dusty conditions.
2 Clean or reptace more often under dirty or dusty conditions.
GENERAL RECOMMENDATIONS
Regular maintenance will improve the performance
and extend the life of the generator. See any authorized Sears dealer for service.
The generator's warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain generator as instructed in this manual.
Some adjustments will need to be made periodically to properly maintain your generator.
All service and adjustments should be made at least once each season. Follow the requirements in the
"Maintenance Schedule" chart above.
NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.
EMISSION CONTROL
Maintenance, replacement or repair of the emission control devices and systems may be performed by any non-road engine repair establishment or individual.
GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign
substances are visible on its exterior surface.
NOTE: DO NOT use a garden hose to clean
generator. Water can enter the engine fuel system and
cause problems. In addition, if water enters the
generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and
stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
Generator Cleaning
Daily or before use, clean accumulated debris from
generator. Keep linkage, spring and controls clean.
Keep area around and behind muffler free from any combustible debris.
Generator parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris.
Use a damp cloth to wipe exterior surfaces clean.
CAUTION
DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
DO NOT insert any objects through cooling slots.
Use a soft bristle brush to loosen caked on dirt, oil, etc.
Use a vacuum cleaner to pick up loose dirt and debris. Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and openings on the generator. These openings must be kept clean
and unobstructed.
13
ENGINE MAINTENANCE
VVARNJNG
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester. DO NOT check for spark with spark plug removed,
Checking Oi_ Leve_
Oil level should be checked prior to each use or at
least every 5 hours of operation. Keep oil level
maintained.
Changing Engine OH
Change the oil after the first 5 hours of operation.
Change oHevery 50 hours thereafter. If you are using your generator under extremely dirty or dusty
conditions, or in extremely hot weather, change the oil
more often.
j cAuTmo.
CJean/Rep_ace Spark P_ug
Change the spark plug every 100 hours of operation or once each year, whichever comes first. This will help your engine to start easier and run better.
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Check electrode gap with wire feeler gauge and set spark plug gap to 0.030 inch (0.76mm) if necessary.
4. Replace spark plug if electrodes are pitted, burned or porcelain is cracked. Use a recommended replacement plug.
NOTE: You can purchase a new spark plug by calling 1-800-366-PART.
Service Air Cleaner
Your engine will not run properly and may be damaged if you run it using a dirty air cleaner. Clean or replace the air cleaner paper filter once every
1
25 hours of operation or once a year, whichever comes first. Clean or replace more often if operating under dusty or dirty conditions.
Used motor oil has been shown to cause skin cancer in certain laboratory animals,
Thoroughly wash exposed areas with soap and water,
KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO
COLLECTION CENTERS.
Change the oil while the engine is still warm from running, as follows:
1. Clean area around oil drain plug. The oil drain plug is located at base of engine, opposite
carburetor.
2. Remove oil drain plug and oil fiJJcap and drain oil completely into a suitable container.
3. Install oil drain plug and tighten securely.
4. FiJJoil sump with recommended oil to the point of
overflowing. See page 7 for oil recommendations.
5. Install oil cap. Tighten cap securely.
6. Wipe up any spilled elk
Service Air FHter
1. Loosen screws and remove air cleaner cover. Remove paper filter.
Cartridge
Cover
Base
S crew
2. Install clean (or new) air cleaner assembly inside cover. Dispose of old filter properly.
3. Assemble air cleaner cover onto base and tighten screws.
NOTE: You can purchase new air cleaner elements by calling 1-800-366-PART.
14
Carburetor
if you think your carburetor needs adjusting, see your nearest Sears service center. Engine performance may be affected at altitudes above 3000 feet. For operation at higher elevations, contact your nearest
Sears service center.
Clean and inspect the spark attester as follows:
1. To remove muffler heat shield from muffler, remove four screws that connect guard to muffler bracket.
CJean Spark Arrester Screen
The engine exhaust muffler has a spark arrester screen. Inspect and clean the screen every 100 hours of operation or once each year, whichever comes first.
WARNING
DO NOT touch hot surfaces.
Allow equipment to cool before touching.
The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
Keep at least 3 feet of clearance on all sides of generator
for adequate cooling, maintenance and servicing.
In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on
federal lands. If you equip the muffler with a spark arrester,
it must be maintained in effective working order.
NOTE: You can purchase a new spark arrester screen
by calling 1-800-366-PART.
if you use your generator on any forest-covered, brush- covered, or grass-covered unimproved land, it must have a spark arrester. The spark arrester must be maintained in good condition by the ownerloperator.
_._park Arrester Screen
eat Shield
.
Remove four screws that attach spark attester
screen.
3.
inspect screen and replace if torn, perforated or othepMse damaged. DO NOT use a defective screen. If screen is not damaged, clean it with
commercial solvent.
4. Reattach screen and muffler guard.
Air Cooming System
Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine
disassembly. For this reason, we recommend you have an authorized Sears service dealer clean the
cooling system per recommended intervals (see "Maintenance Schedule" on page 13). Equally important is to keep top of engine free from debris.
See "Generator Cleaning".
C[ AN
15
Thegeneratorshouldbestartedatleastonceevery sevendaysandallowedtorunatleast30minutes.If thiscannotbedoneandyoumuststoretheunitfor morethan30days,usethefollowinginformationasa guidetoprepareitforstorage.
Long Term Storage _nstructions
it is important to prevent gum deposits from forming in essential fuel system parts, such as the carburetor, fuel filter, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic fuel can damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. Follow
these instructions:
WARNING
WHEN STORING FUELOR EQUIPMENTWITH FUEL IN TANK
Store away fromfurnaces, stoves, water heaters, clothes
dryers or other appliances that havepilot light or other ignition source because they can ignite fuel vapors.
WHEN DRAiNiNG FUEL
Turn generator OFF and let itcool at least 2 minutes
before removing fuel cap. Loosen cap slowly to relieve pressure intank.
Drain fuel tank outdoors.
Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources,
DO NOT light a cigarette or smoke.
Protect Fuet System
1. Remove all gasoline from fuel tank to prevent gum deposits from forming on these parts and causing
possible malfunction of engine.
2. Run engine until engine stops from lack of fuel.
Change OH
While engine is still warm, drain oil from crankcase.
Refill with recommended grade. OHCylinder Bore
Remove spark plug and pour about 1 ounce (30ml) of clean engine oil into the cylinder.
Install spark plug and crank slowly to distribute oil.
WARNING
NEVER crank enqine with spark plug removed,
Generator
1. Clean generator as outlined in "Generator Cleaning".
2. Check that cooling air slots and openings on generator are open and unobstructed.
Other Storage Tips
1. DO NOT store fuel from one season to another.
2. Replace fuel can if it starts to rust. Contaminated fuel will cause engine problems.
3. If possible, store unit indoors and cover it to give protection from dust and dirt. BE SURE TO
EMPTY FUEL TANK.
4. Cover unit with a suitable protective cover that does not retain moisture.
WARNING
DO NOT place a storage cover over a hot generator. Let equipment coo! for a sufficient time before placing
the cover on the equipment.
.
Store generator in clean, dry area.
16