WARNING: To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit
panel before you begin the fan installation or before servicing the fan or installing accessories.
1. READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN
AND SAVE THESE INSTRUCTIONS.
CAUTION: To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp
edges.
2. Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code,
and ANSI/NFPA 70-1999. If you are unfamiliar with electrical wiring or if the house/building wires are
different colors than those referred to in the instructions, please use a qualified electrician.
3. Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at
least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips. The fan should
be mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or
other upright structures.
4. The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at
least 35 pounds (16 kilograms). The box must be supported directly by the building structure. Use only
UL listed outlet boxes marked "FOR FAN SUPPORT."
WARNING: To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked
"Acceptable for Fan Support of 15.9 kg (35 lb) or less," and use the mounting screws provided with the outlet
box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING: To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan
are designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is
larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires,
consult an electrician for the proper size wire connectors to use.
WARNING: If using this fan in a DAMP location, this fan must be connected to a supply circuit that is protected
by a Ground Fault Circuit Interrupter (GFCI) to reduce the risk of personal injury, electrical shock or death.
5. Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL listed and
marked suitable for use with the model fan you are installing. Switches must be UL general use
switches. Refer to the instructions packaged with the light kits and switches for proper assembly.
6. After installation is complete, check that all connections are absolutely secure.
7. After making electrical connections, spliced conductors should be turned upward and pushed carefully up
into the outlet box. The wires should be spread apart with the grounded conductor and the
equipment-grounding conductor on opposite sides of the outlet box.
WARNING: To reduce the risk of electrical shock, fire and to prevent humming noise do not use this fan with any
solid state speed control device or control fan speed with a full range dimmer switch. [Using a full range dimmer
switch to control fan speed will cause a loud humming noise from fan.] (Note: This fan is suitable for use with
remote control approved for DAMP locations.)
8. Do not operate the reverse switch until fan has come to a complete stop.
9. Do not insert anything between the fan blades while they are rotating.
WARNING: To reduce the risk of personal injury, do not bend the blade arms during assembly or after
installation. Do not insert objects into the path of the blades.
WARNING: To avoid personal injury or damage to the fan and other items, be cautious when working around or
cleaning the fan.
10. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened
cloth will be suitable for most cleaning.
WARNING: To reduce the risk of personal injury, use only parts provided with this fan. The use of parts OTHER
than those provided with this fan will void the warranty.
NOTE: The important safety precautions and instructions appearing in the manual are not meant to cover all
possible conditions and situations that may occur. It must be understood that common sense and caution are
necessary factors in the installation and operation of this fan.
page 1
1. Unpacking Your Fan.
Carefully open the packaging. Remove items
from Styrofoam inserts. Remove motor housing
and place on carpet or Styrofoam to avoid
damage to finish. Do not discard fan carton or
Styrofoam inserts should this fan need to be
returned for repairs.
Check against parts inventory that all parts have
been included.
2. Parts Inventory.
a. hanging bracket. 1 piece
b. remote control transmitter. 1 piece
abc
c. remote control receiver. 1 piece
d. wall control and plate. 2 separate pieces
e. 6in. downrod and hanging ball. 1 piece
f. canopy. 1 piece
g. yoke cover. 1 piece
h. motor housing. 1 piece
i. blade arm. 5 pieces
j. blade. 5 pieces
k. hardware packs
d
g
i
j
k
ef
h
w/ remote
IMPORTANT REMINDER: You must
use the parts provided with this fan for
proper installation and safety.
page 2
3. Installation Preparation.
blade edge
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a downrod
on a regular (no-slope) or vaulted ceiling. The
hanging length can be extended by purchasing a
longer downrod (0.5in./1.27cm diameter). Other
installation, such as flushmount, is not available
for this fan.
Installation requires these tools:
Phillips screwdriver, flathead screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
30
inches
(76cm)
7 feet
(2.13m)
downrod
installation
12ft. - 20ft.
(3.66m - 6.1m)
12ft. - 20ft.
(3.66m - 6.1m)
flushmount
installation
Vaulted ceiling
angle is not to
exceed 25 degrees.
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to
the OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure
the outlet box is securely attached to the building
structure and can support the full weight of the fan.
Ensure the outlet box is clearly marked "Suitable for Fan
Support." If not, it must be replaced with an approved
outlet box. Failure to do so can result in serious injury.
CAUTION: Be sure outlet box is grounded and that a
ground wire (GREEN or bare) is present.
Install hanging bracket to outlet box using original
screws, spring washers and flat washers provided with
new or original outlet box.* If installing on a vaulted
ceiling, face opening of hanging bracket towards high
point of ceiling. Arrange electrical wiring around the
back of the hanging bracket and away from the
bracket opening.
*Note: It is very important that you use the proper
hardware when installing the hanging bracket as this will
support the fan.
hanging bracket
flat washers
spring washers
outlet box screws
ON
ON
OFF
OFF
page 3
5. F
an Assembly.
If you wish to extend the hanging length of
your fan, you must remove the hanging ball
from the 6in. downrod provided to use with an
extended downrod (sold separately). [If you
wish to use the 6in. downrod, please proceed to
instructions following the dotted line below.]
To remove hanging ball, loosen set screw on
hanging ball, lower hanging ball and remove
stop pin. Slide hanging ball off the original
downrod, A, and slide it down the longer
downrod, B (the top of the downrod should be
noted as having a set screw hole; use this hole
when setting the set screw). Insert stop pin into
top of extended downrod and raise hanging
ball. Be sure stop pin aligns with slots on the
inside of the hanging ball. Tighten set screw
securely.
Tip: To prepare for threading electrical wires
through downrod, apply a small piece of
electrical tape to the ends of the electrical
wires--this will keep the wires together when
threading them through the downrod.
set screw
A
electrical wiring
set screw hole
stop pin
hanging ball
B
Loosen yoke set screws and nuts and remove
pin and clip at top of motor housing. Slide
downrod through canopy and yoke cover.
Thread electrical wires through downrod and
pull extra wire slack from the upper end of the
downrod.
Thread downrod into the motor yoke until
holes for pin and clip in downrod align with
holes in yoke--make sure wires do not get twisted. Re-insert pin and clip. Tighten yoke set
screws and nuts securely. Lower yoke cover to
motor housing.
["Fan Assembly" continued on next page.]
NOTE: The important safety precautions and
instructions appearing in the manual are not
meant to cover all possible conditions and
situations that may occur. It must be understood
that common sense and caution are necessary
factors in the installation and operation of this fan.
pin
downrod
canopy
yoke cover
yoke set screw
clip
motor
housing
page 4
wall
5. F
an Assembly. (cont.
)
With the hanging bracket secured to the outlet box
and able to support the fan, you are now ready to
hang your fan. Grab the fan firmly with two hands.
Slide downrod through opening in hanging bracket
and let hanging ball rest on the hanging bracket.
Turn the hanging ball slot until it lines up with the
hanging bracket tab.
WARNING: Failure to align slot in hanging ball with
tab in hanging bracket may result in serious injury
or death.
Tip: Seek the help of another person to hold the
stepladder in place and to lift the fan up to you
once you are set on the ladder.
hanging bracket tab
hanging ball slot
6. Wiring.
CAUTION: Be sure outlet box is properly grounded
and that a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code. If you are unfamiliar with electrical
wiring or if the house/building wires are different
colors than those referred to in the diagram to the
right, please use a qualified electrician.
WARNING: If using this fan in a DAMP location,
this fan must be connected to a supply circuit that
is protected by a Ground Fault Circuit Interrupter
(GFCI) to reduce the risk of personal injury,
electrical shock or death.
When downrod is secured in place on the hanging
bracket, wire the RECEIVER with wire connectors
provided as shown in diagram at right.Tip: While you are wiring, keep in mind that wires
must not obstruct receiver from sliding into
hanging bracket.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
white supply wire
black supply wire
blue
white
black
from fan
from receiver
black
white
blue
receiver
(wiring for receiver)
ground (green
or bare)
ground (green
or bare)
white
black
from ceiling
from receiver
black
AC IN L
white
AC IN N
antenna
Gently insert receiver (flat side up) into hanging
bracket and carefully push taped wire connectors
into outlet box. Allow antenna from remote
control receiver to hang outside of hanging
bracket.
Modifications not approved by the party responsible for compliance could
void the user's authority to operate the equipment.
*NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.