CPT CLAA320WF01U Specification

Global LCD Panel Exchange Center
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
RECORD OF REVISIONS
Revision No. Date Page Description
Ver 1.0 2008/01/23 -- The first edition issued.
˅
CPT Confidential
ʳ
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
/26
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
CONTENTS
No Item Page
1 OVERVIEW 4
2 ABSOLUTE MAXIMUM RATINGS 5
3 ELECTRICAL CHARACTERISTICS 6
4 INTERFACE PIN CONNECTION 11
5 INTERFACE TIMING 14
6 BLOCK DIAGRAM 19
7 MECHANICAL SPECIFICATION 20
8 OPTICAL CHARACTERISTICS 22
9 RELIABILITY TEST CONDITIONS 27
10 HANDLING PRECAUTIONS FOR TFT-LCD MODULE 28
ˆ
CPT Confidential
ʳ
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
/26
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
1. OVERVIEW
CLAA320WF01U is 32” color (80.04cm) TFT-LCD (Thin Film Transistor Liquid Crystal Display) module composed of LCD panel, LVDS driver ICs, control circuit, backlight, and inverter. By applying 8 bit digital data, 1366*768, 16.7 million-color images are displayed on the 32” diagonal screen. General specification are summarized in the following table:
1.1 GENERAL INFORMATION
Item Specification Unit
Display Area 697.684(H) × 392.256(V) (31.51 inch diagonal) mm
Number of Pixels 1366×3(H)×768(V) 16:9
Pixel Pitch 0.51075(H) × 0.51075(V) mm
Bezel Opening Area 703.6×398.3 mm
Color Pixel Arrangement RGB Vertical Strip
Display Mode Normally Black
Number of Colors 16.7M (8bits) color
Wide View Tech. E-MVA
Electrical Interface LVDS
Total Module Power
(B/L with inverter105W)
114 (Typ.)
W
Horizontal(H) 760.0 (Typ) mm
Module Outline
Dimension
Depth
Vertical(V) 450.0 (Typ) mm
without inverter 38.0 (Typ) mm
(D)
with inverter 45.0 (Typ) mm
Module Weight 7500 (Typ) g
Backlight Unit 7U-CCFL
Surface Treatment
Hard coating, Anti-glare
Surface-hardness: 3H
The LCD products listed on this document are not suitable for use of aerospace equipment, submarine cables, and nuclear reactor control system and life support systems. If customers intend to use these LCD products for above application or not listed in "Standard" as follows, please contact our sales people in advance.
Standard : Computer, Office equipment, Communication equipment, Test and Measurement
equipment, Machine tool, Industrial robot, Audio and Visual equipment, & Other consumer products.
ˇ
CPT Confidential
ʳ
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
/26
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com
Global LCD Panel Exchange Center
]
p
p
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
2. ABSOLUTE MAXIMUM RATINGS
The following are maximun values which, if exceeded, may cause faulty operation or damage to the unit.
Item Symbol Min. Max. Unit Note
Power Supply Voltage For LCD VCC -0.3 14.0 V Input Voltage of Inverter VBL -0.3 27.0 V Invert Dimming VDIM -0.3 3.5 Vdc BL on/off BL ON -0.3 5.5 Vdc ESD for Connector VESD -250 250 V *5) ESD for Module VESD Operation Temperature (Surrounding) Top Storage Temperature Tstg -20 60 к *1) *2) *3) *4) Delayed Discharge Time TD -- 1 sec *6)
[Note]
*1) The relative temperature and humidity range are as below sketch.(90%RHMax / Ta 40 )Љк *2) The maximum wet bulb temperature 39Љк (TaЇ40 ) and without dewing.к
*3) If you use the product in a environment which over the definition of temperature and
humidity too long, and it will effect the result of visible inspection.
-15 15 KV *5)
0 50 к *1) *2) *3) *4)
*4) While the product operates in normal temperature range, the center surface of panel
should be under 60 .к
Humidity 85%RH without condensation.Љ
Relative Humidity 90% (Ta 40 )ЉЉк
Wet Bulb Temperature Љ39к (Ta40)Њк
ˌ˃ʸ
ˉ˃
ˉ˃ʸ
Wet Bulb Tem
erature [C]ʳ
ˇ˃
˄˃ʳ
0
˅˃ʳ
ˆ˃ʳ
ˈ˃
ˇ˃ʸ
Humidity [(%)RH]
˄˃ʸ
Storage
O
eration
-20
˄˃ʳ ˅˃ʳ ˆ˃ʳ ˇ˃ ˈ˃ ˉ˃ ˊ˃
˃ʳ
Dry Bulb Temperature [C
ˋ˃
*5) Test Condition: IEC 1000-4-2 VESDt: Contact discharge to input connector; VESDC:
Contact discharge to module.
*6) Delay lighting testing needs the volt above start voltage Vrms. Before the procedure tube
needs typical lighting for 1 minute and stay in the temperature 25±2 for 24 hours and к then testing in the same condition in dark room.
ˈ
CPT Confidential
ʳ
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
/26
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
3. ELECTRICAL CHARACTERISTICS
3.1 TFT-LCD MODULE ITEM SYMBOL MIN TYP MAX UNIT REMARK
LCD Power Supply Voltage VCC 11.4 12.0 12.6 V *1)
Ripple Voltage Vrpd -- -- 100 mVp-p VCC=+12.0V
Rush Current Irush -- -- 4 A *2)
LCD Power
Supply Current
RGB stripe
LCD Power Consumption Pc -- 9 12 W
High Input Voltage of LVDS V
Low Input Voltage of LVDS V
Input Common Voltage of LVDS VCM -- 1.25 - V
Input Terminal Resist of LVDS R
Ta=25к
White -- 700 900 *3)
Black -- 450 600
ICC
mA
-- 700 900
IN+
IN-
T
-- -- 100 mV [Note 4]
100 -- -- mV
-- 100 -- ohm
[Note]
*1) The module should be always operated within above ranges. *2) Measure conditions:
ʻ˛˼˺˻ʳʳ˿ʼʳ
ʻ˶˿ʳ˼˺˴˿ʼ
˗˖
ʾ˄ˈ˩
˗˖
ʾ˄˅˩
˦˪
˖˄
˄˙
˩˥˄
ˇˊ˾
ˤ˄ʳʳ
˅˦˞˄ˇˊˈ
˥˄
ˇˊ˾
˅˦˞˄ˇˊ˃
˥˅ ˄˾
˖˅
˃ˁ˃˄˙
˙˨˦˘
ˤ˅ʳʳ
˚ˡ˗
˖ˆ
˄˙
˃ˁ˄˩˶˶
˩˖˖
˟˖˗ʳˠ˷˿˸ʳ
˜
ʾ˄˅˩
˃ˁˌ˩˶˶
˄
VCC rising time is 0.5 ms
ˉ
CPT Confidential
ʳ
/26
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
*3) The specified power supply current is under condition at Vcc=12V, Ta=25±2к, fv=60Hz,
whereas a power dissipation check pattern below is displayed.
a. White pattern b. Black pattern c. RGB Stripe pattern
*4) Power and Signal Sequence:
VCCΚ12V
90%
10%
Power Supply
(VCCΚ12V)
90%
10%
Interface Signal
(LVDS Data with H,Vsync
and DE)
Power Supply for
Backlight
Power Sequence Table
Parameter
Min Typ Max
T1 0.5 --- 30 ms T2 1 --- 50 ms T3 0 --- 50 ms T4 2000 --- ʳ ms T5 110 --- ʳ ms
T1 T4
T2 T3
T5
T6
BL on
Value
Unit
T6 100 --- ʳ ms
Notes:
Please avoid floating state of interface signal at invalid period.
When the interface signal is invalid, be sure to pull down the power supply for LCD to 0V.
Lamp power must be turn off after power supply for LCD interface signal valid.
ˊ
CPT Confidential
ʳ
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
/26
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
VCC-dip state :
1) When 9V Љ VCCІ11.4 V, tdЉ10 ms.
2) VCC Ї 11.4V, VCC- dip condition should also follow the VCC-turn-off condition.
VCC
9V 11.4V
td
*5) LVDS Signal Definition:
RUʳ
VID = VIN
– VIN-,
+
VCM = Ϧ ΨVCM
VID = Ϧ ΨVID
VID+ = ΨVIH
VID- = ΨVIL
VCM = ( VIN
VCM+ = ( VIH
VCM- =( VIL
–VCM-Ψ,
+
–VID-Ψ,
+
–VIH-Ψ,
+
–VIL-Ψ,
+
+VIN- ) / 2,
+
+VIH- ) / 2,
+
+VIL- ) / 2,
+
VIN+: Positive Polarity differential DATA & CLK input
VIN-: Negative Polarity differential DATA & CLK input
ˋ
CPT Confidential
ʳ
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
/26
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
CPT CHUNGHWA PICTURES TUBES, LTD.,
ʳ
3.2 BACKLIGHT
Ta = 25°C,VCC=12V, Turn on for 30 minutes
Item Symbol Min. Typ. Max. Unit Note
Lamp Life Time LT 50000 -- -- hr *1)
Input Voltage VIN 21.6 24.0 26.4 V *2)
Input Current IIN -- 4.38 5.2 A *3)
Internal Dimming Control
Voltage
Inverter Duty Ratio D 20 -- 100 %
PWM Dimming Control
Frequency
ON/OFF
Control Voltage
Power Consumption
(Backlight )
PDIM 0 -- 3.3 V *4)
FPWM 100 180 350 Hz
ON 2.0 5.0
OFF
ON/OFF
0 0.8
V
BLW -- 105 132 W *3)
*1) Definition of the lamp life time: When lamp luminance redue to 50% or lower than its
initial value.
*2) Ripple voltage that occur at the instant of power-on can’t exceed 27V.
*3) Max value of the power consumption and input current is measured at initial turn on of
the backlight.
*4) Internal PWM control with Analog input voltage.
Brightness is the darkest when P
Brightness is the brightest when P
CPT Confidential
ʳ
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
ˌ
/26
= 0V;
DIM
= 3.3V
DIM
CLAA320WF01_UD-HUI YING TUNG-SPEC-20080128
www.panelook.com