C Prox Ltd FP1 User Manual

Page 1
1
C Prox Ltd (inc Quantek)
59 Sheffield Road, Dronfield, S18 2GF
Standalone Fingerprint Access Control
FP1
User Manual
Please read the manual carefully before installing this unit
Page 2
2
1. Packing list
Name
Quantity
Remarks
Fingerprint reader
FP1 1
Infrared remote control
1
User manual
1
Screw driver
1
Special screw tool
Diode
1
IN4004
Rubber
wall plug 4
Φ6mm
×25 mm, used for fixing
Self-tapping
screws
4
Φ4mm
×25 mm, used for fixing
Please ensure that all the above contents are correct. If any are missing please notify us immediately.
2. Description
The FP1 is a metal zinc alloy shell standalone fingerprint reader for access control. It uses the American Atmel’s MCU, with precise electron circuit and good productive technology. This unit applies world advanced fingerprint identification technology, making it safe and reliable, which means it is an ideal choice for situations demanding high security. Its programming is done by infrared remote control or master fingerprint. It can store up to 1,000 fingerprints, including two master fingerprints and 998 user fingerprints. Each fingerprint has one ID code.
3. Functions
Sleeping function
High environmental awareness energy-saving control system, with auto sleep and wake up function. The sleeping power consumption is less than 0.20W.
Master fingerprints operation function
This device can add/delete users fingerprints by master fingerprints quickly and easily. (One add master fingerprint, one delete master fingerprint.
Infrared programmer
Supplied with an infrared programmer to allow easy add/delete of fingerprint. Useful if a user fingerprint needs to be deleted without them being present.
Lock driving function
With NC, NO and COM, the control time is 0 – 99 seconds. (0s is 50ms). Wires are isolated from the inner circuit, the contactors current is 2A.
Anti-tamper alarm function
When the unit is disassembled, the internal buzzer will sound a consecutive alarm for one minute.
Page 3
3
4. Specification
Input voltage
12V dc ± 10%
Sleeping current consumption
≤20mA
Idle current consumption
≤80mA
Door relay contact load
2A
Operating
temperature
-20 to 5
0⁰C
Operating humidity
20% to 95% RH
Fingerprint capacity
1000
Resolution
450 DPI
Fingerprint input time
<1s
Identification time
<1s
FAR <0.0000256%
FRR <
0.0198%
Structure
Zinc alloy
Dimensions
115 x 70 x 35 mm
Weight
500g
5. Installation
Remove the back cover using the supplied security driver
Use the back cover to mark the four fixing holes and one cable hole, drill holes.
Fit back cover firmly to the wall using the wall plugs and self-tapping screws.
Thread the wires through the hole.
Attach the front to the back cover.
Page 4
4
6. Wiring
Colour Function Description
Yellow OPEN Exit button Red 12V + 12V + DC regulated power input Black GND 12V – DC regulated power input Blue NO Relay output NO Purple COM Relay output COM Orange NC Relay output NC
7. To reset to factory default
a. Disconnect power from the unit. b. Press and hold the ‘Reset’ button on the PCB whilst powering the unit back up. c. On hearing three short beeps, release the ‘Reset’ button, system is now back to factory default.
Please note only installer data is restored, user data will not be affected.
8. Sound and light indication
Operation Status Indicator Light Colour Finger Sensor Light Buzzer Description Buzzer
Power On Slow flash in red Bright Long ring
Di -
Sleeping Slow flash in red Goes out
Voided Key
Short ring
Di
Enter Programming Red Goes out Long ring
Di -
Programming Orange
Input Fingerprint
successful
Green
Long ring
Di ---
Input Fingerprint Failed
3 short rings
Di Di Di
Unlock the Door Green Goes out Long ring
Di -
Alarm Quick flash in red Bright Continuous long ring
Di……
Page 5
5
9. Programming guide
10. Anti-tamper alarm
When the unit is removed illegally the anti-tamper switch will be activated and the internal alarm will sound for one minute. Or it can be turned off in the following ways: Input .Master fingerprint. or .User fingerprint. or .Master code.
To enter programming mode
.*. Master code .#.
9999 is the default master code
To exit programming mode
.*.
Note that to undertake the following programming the master user must be logged in
To change the master code
.0. .New code. .#. .New code. .#.
The master code is any 4 digits
To add a fingerprint
.1. ID code .#. .Input fingerprint. .Input fingerprint. .#.
ID code range is 1 to 1000. ID code 1 is master add fingerprint, ID code 2 is master delete fingerprint, ID code 3 to 1000 are users’ fingerprints. Each ID code be assigned one fingerprint, master fingerprints must be added by ID code. Advice for adding fingerprints: when the LED lights up, input fingerprint. It gives a short beep when the fingerprint is inputted for the first time. Release fingerprint, then input the same fingerprint again. The unit will emit a longer beep and the LED will turn green, this means the fingerprint has been successfully added. If the operation has failed, three short beeps will be emitted, attempt the process again. In order to improve the success rate, please put middle of the fingerprint on the middle of the induction area.
To add users continuously
ID code will be auto generated, from 3 to 1000
.7. .1st user fingerprint twice..Nth user fingerprint
twice. .#.
To delete a fingerprint
.2. .ID code. .#.
Users can be deleted continuously without exiting programming mode
To delete users continuously
Each fingerprint only needs to be inputted once
.8. .1st user fingerprint..Nth user fingerprint. .#.
To delete all fingerprints
This process deletes all users, so use with care
.2. 0000 .#.
Add/delete users by master fingerprints
To add fingerprint users
Input .Master add fingerprint. .1st user fingerprint twice.
.Nth user fingerprint twice. .Master add fingerprint.
To delete fingerprint users
Input .Master delete fingerprint. .1st user fingerprint.
.Nth user fingerprint. .Master delete fingerprint.
To set door open time
.4. 0 – 99 .#.
0 – 99 is to set the door relay time to 0 – 99 seconds
To unlock the door
In standby state, input valid user fingerprint, door will open
Loading...