59 Sheffield Road, Dronfield, S18 2GF
+44(0)1246 417113 sales@cproxltd.com www.quantek.co.uk
Standalone Fingerprint Access Control
FP1
User Manual
Please read the manual carefully before installing this unit

Please ensure that all the above contents are correct. If any are missing please notify us immediately.
2. Description
The FP1 is a metal zinc alloy shell standalone fingerprint reader for access control. It uses the American
Atmel’s MCU, with precise electron circuit and good productive technology. This unit applies world
advanced fingerprint identification technology, making it safe and reliable, which means it is an ideal
choice for situations demanding high security. Its programming is done by infrared remote control or
master fingerprint. It can store up to 1,000 fingerprints, including two master fingerprints and 998 user
fingerprints. Each fingerprint has one ID code.
3. Functions
Sleeping function
High environmental awareness energy-saving control system, with auto sleep and wake up function. The
sleeping power consumption is less than 0.20W.
Master fingerprints operation function
This device can add/delete users fingerprints by master fingerprints quickly and easily. (One add master
fingerprint, one delete master fingerprint.
Infrared programmer
Supplied with an infrared programmer to allow easy add/delete of fingerprint. Useful if a user fingerprint
needs to be deleted without them being present.
Lock driving function
With NC, NO and COM, the control time is 0 – 99 seconds. (0s is 50ms). Wires are isolated from the inner
circuit, the contactors current is 2A.
Anti-tamper alarm function
When the unit is disassembled, the internal buzzer will sound a consecutive alarm for one minute.

Sleeping current consumption
5. Installation
• Remove the back cover using the supplied security driver
• Use the back cover to mark the four fixing holes and one cable hole, drill holes.
• Fit back cover firmly to the wall using the wall plugs and self-tapping screws.
• Thread the wires through the hole.
• Attach the front to the back cover.

4
6. Wiring
Colour Function Description
Yellow OPEN Exit button
Red 12V + 12V + DC regulated power input
Black GND 12V – DC regulated power input
Blue NO Relay output NO
Purple COM Relay output COM
Orange NC Relay output NC
7. To reset to factory default
a. Disconnect power from the unit.
b. Press and hold the ‘Reset’ button on the PCB whilst powering the unit back up.
c. On hearing three short beeps, release the ‘Reset’ button, system is now back to factory default.
Please note only installer data is restored, user data will not be affected.
8. Sound and light indication
Operation Status Indicator Light Colour Finger Sensor Light Buzzer Description Buzzer
Power On Slow flash in red Bright Long ring
Sleeping Slow flash in red Goes out
Voided Key
Short ring
Di
Enter Programming Red Goes out Long ring
Di -
Programming Orange
successful
Green
Long ring
Di ---
Input Fingerprint
Failed
3 short rings
Di Di Di
Unlock the Door Green Goes out Long ring
Di -
Alarm Quick flash in red Bright Continuous long ring
Di-……

5
9. Programming guide
10. Anti-tamper alarm
When the unit is removed illegally the anti-tamper switch will be activated and the internal alarm will
sound for one minute. Or it can be turned off in the following ways: Input .Master fingerprint. or .User
fingerprint. or .Master code.
To enter programming mode
.*. Master code .#.
9999 is the default master code
.*.
Note that to undertake the following programming the master user must be logged in
To change the master code
.0. .New code. .#. .New code. .#.
The master code is any 4 digits
.1. ID code .#. .Input fingerprint. .Input fingerprint. .#.
ID code range is 1 to 1000. ID code 1 is master add fingerprint, ID code 2 is master delete fingerprint, ID code 3 to
1000 are users’ fingerprints. Each ID code be assigned one fingerprint, master fingerprints must be added by ID code.
Advice for adding fingerprints: when the LED lights up, input fingerprint. It gives a short beep when the fingerprint is
inputted for the first time. Release fingerprint, then input the same fingerprint again. The unit will emit a longer beep
and the LED will turn green, this means the fingerprint has been successfully added. If the operation has failed, three
short beeps will be emitted, attempt the process again. In order to improve the success rate, please put middle of the
fingerprint on the middle of the induction area.
To add users continuously
ID code will be auto generated, from 3
to 1000
.7. .1st user fingerprint twice. … .Nth user fingerprint
twice. .#.
.2. .ID code. .#.
Users can be deleted continuously without exiting programming mode
To delete users continuously
Each fingerprint only needs to be
inputted once
.8. .1st user fingerprint. … .Nth user fingerprint. .#.
To delete all fingerprints
This process deletes all users, so use
with care
.2. 0000 .#.
Add/delete users by master fingerprints
Input .Master add fingerprint. .1st user fingerprint twice. …
.Nth user fingerprint twice. .Master add fingerprint.
To delete fingerprint users
Input .Master delete fingerprint. .1st user fingerprint. …
.Nth user fingerprint. .Master delete fingerprint.
.4. 0 – 99 .#.
0 – 99 is to set the door relay time to 0 – 99 seconds
In standby state, input valid user fingerprint, door will open