CPCLA CPC7581BA-TR, CPC7581BA, CPC7581BB-TR, CPC7581BB Datasheet

1
www.clare.com
CPC7581
DS-CPC7581-R2
The CPC7581 is a monolithic solid state switch in a 16 pin surface mount SOIC package. It provides the necessary functions to replace a 2-Form-C electromechanical relay on analog line cards found in Central Office, Access and PBX equipment. The device contains solid state switches for tip and ring line break and ring injection/ring return. The CPC7581 requires only a +5V supply and offers “break-before-make” or “make-before-break” switch oper­ation using simple logic level input control. There are two versions of the CPC7581, the CPC7581BA and the CPC7581BB. The “BA” version has a protection SCR which provides protection to the SLIC device and subse­quent circuitry during fault conditions.
Central office (CO)
Digital Loop Carrier (DLC)
PBX Systems
Digitally Added Main Line (DAML)
Hybrid Fiber Coax (HFC)
Fiber in the Loop (FITL)
Pair Gain System
Channel Banks
Small 16 pin surface mount SOIC package
Monolithic IC reliability
Low matched RDS
ON
Eliminates the need for zero cross switching
Flexible switch timing to transition from ringing mode
to idle/talk mode
Clean, bounce free switching
Tertiary Protection consisting of integrated current
limiting, thermal shutdown and SLIC protection
5V operation with power consumption <10mW
Intelligent battery monitor
Latched logic level inputs, no drive circuitry
Pin to pin compatible to the Lucent 7581 family
Applications
Features
Description
Line Card Access Switch
Ordering Information
Part # Description
CPC7581BA 4 Pole with protection SCR CPC7581BB 4 Pole without protection SCR CPC7581BA-TR Tape & Reel Version CPC7581BB-TR Tape & Reel Version
Block Diagram
TIP
Ring
R1
(6)
T
RING
SW3
Ringing
T
(3)
LINE
Secondary
Protection
R2
R
(14)
LINE
Return
SW4 Ringing Access
R
RING
Break
Break
Ring Generator
(12)
SW1
SW2
-
+
CPC7581BA
Battery
SCR
and Trip
Circuit
V
BAT
Reference (16)
(2)
T
BAT
SLIC
R
(15)
BAT
www.clare.com
CPC7581
Rev. 2
Absolute Maximum Ratings are stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for extended period may degrade the device and effect its reliability.
Absolute Maximum Ratings (@ 25˚ C)
2
Electrical Characteristics TA = -40oC to +85oC (unless otherwise specified)
Minimum and maximum values are production testing requirements. Typical values are characteristic of the device and are the result of engineering evaluations. Typical values are provided for information purposes only.
1
V
BAT
is used only as a reference for internal protection circuitry.
If V
BAT
rises above -10V, the device will enter an all off state and will remain in the all off state until the battery voltage drops below -15V.
Power Supply Specifications
Supply Min Typ Max Unit
V
DD
+4.5 +5.0 +5.5 V
V
BAT
1
-19 - -72 V
ESD Rating (HBM)
1000V
Table 1. Break Switch, SW1 and SW2
PARAMETERS CONDITIONS SYMBOL MIN TYP MAX UNITS
Off-state Leakage Current: +25˚C Vsw (differential)= -320V to Gnd Isw - 0.1 1 µA
Vsw (differential)= -60V to +260V
+85˚C Vsw (differential)= -330V to Gnd Isw - 0.3 1 µA
Vsw (differential)= -60V to +270V
-40˚C Vsw (differential)= -310V to Gnd Isw - 0.1 1 µA Vsw (differential)= -60V to +250V
RDSON(SW1,SW2): +25˚C T
LINE
= +/-10 mA, +/-40mA, T
BAT
= -2V ∆ V - 14.5 -
+85˚C T
LINE
= +/-10 mA, +/-40mA, T
BAT
= -2V ∆ V - 20.5 28
-40˚C T
LINE
= +/-10 mA, +/-40mA, T
BAT
= -2V ∆ V - 10.5 -
RDS
ON
Match Per ON-resistance Test Condition of Magnitude - 0.15 0.8
SW1, SW2 RONSW1-RONSW2
dc Current Limit: - - - - ­+25˚C Vsw (on) = +/- 10V Isw - 300 - mA +85˚C Vsw (on) = +/- 10V Isw 80 160 - mA
-40˚C Vsw (on) = +/- 10V Isw - 400 425 mA
Dynamic Current Limit: Break switches in ON state, Ringing Isw - 2.5 - A
(t=<0.5µs) access switches OFF, Apply +/- 1000V
at 10/1000µs pulse, Appropriate secondary protection in place.
Logic Input to Switch Output Isolation +25˚C Vsw (T
LINE
, R
LINE
) = +/-320V Isw - 0.1 1 µA
Logic Inputs = Gnd
+85˚C Vsw (T
LINE
, R
LINE
) = +/-330V Isw - 0.3 1 µA
Logic Inputs = Gnd
-40˚C Vsw (T
LINE
, R
LINE
) = +/-310V Isw - 0.1 1 µA
Logic Inputs = Gnd
dv/dt Sensitivity
1
- - - 200 - V/µs
1
Applied voltage is 100 Vp-p square wave at 100Hz.
Parameter Min Max Units
Operating Temperature Range -40 +110 ˚C Storage Temperature Range -40 +150 ˚C Relative Humidity Range 5 95 % Pin Soldering Temperature - +260 ˚C
(t=10 s max) +5V Power Supply - 7 V Battery Supply - -85 V Logic Input Voltage - 7 V Logic Input to Switch Output Isolation - 330 V Switch Isolation (SW1, SW2, SW3) - 330 V Switch Isolation (SW4) - 480 V
CPC7581
www.clare.com
Rev. 2
3
Table 3. Ringing Access Switch, SW4
PARAMETERS CONDITIONS SYMBOL MIN TYP MAX UNITS
Off-state Leakage Current +25˚C Vsw (differential)= -255V to +210V Isw - .05 1 µA
Vsw (differential)= +255V to -210V
+85˚C Vsw (differential)= -270V to +210V Isw - 0.1 1 µA
Vsw (differential)= +270V to -210V
-40˚C Vsw (differential)= -245V to +210V Isw - .05 1 µA
Vsw (differential)= +245V to -210V ON Voltage Isw (on) = +/- 1mA - - 1.5 3 V Ring Generator Current Vcc = 5V, INaccess = 0 I
R
- 0.1 0.25 mA
During Ring Surge Current - - - - 2 A Release Current - - - 300 - µA RDS
ON
Isw (on) = +/-70mA, +/-80mA ∆ V - 8.5 12 Logic Input to Switch Output Isolation +25˚C Vsw (R
RING
, R
LINE
) = +/-320V Isw - .05 1 µA
Logic Inputs = Gnd +85˚C Vsw (R
RING
, R
LINE
) = +/-330V Isw - 0.1 1 µA
Logic Inputs = Gnd
-40˚C Vsw (R
RING
, R
LINE
) = +/-310V Isw - .05 1 µA
Logic Inputs = Gnd
Table 2. Ring Return Switch, SW3
PARAMETERS CONDITIONS SYMBOL MIN TYP MAX UNITS
Off-state Leakage Current +25˚C Vsw (differential)= -320V to Gnd Isw - 0.1 1 µA
Vsw (differential)= -60V to +260V +85˚C Vsw (differential)= -330V to Gnd Isw - 0.3 1 µA
Vsw (differential)= -60V to +270V
-40˚C Vsw (differential)= -310V to Gnd Isw - 0.1 1 µA
Vsw (differential)= -60V to +250V
dc Current Limit: +25˚C Vsw (on) = +/- 10V Isw - 135 - mA +85˚C Vsw (on) = +/- 10V Isw - 85 - mA
-40˚C Vsw (on) = +/- 10V Isw - 210 - mA Dynamic Current Limit: Break switches in ON state, Ringing Isw - 2.5 - A
(t=<0.5µs) access switches OFF, Apply +/- 1000V
at 10/1000ms pulse, Appropriate
secondary protection in place.
RDS
ON
+25˚C Isw (on) = +/-0mA, +/-10mA ∆ V-60- +85˚C Isw (on) = +/-0mA, +/-10mA ∆ V - 85 100
-40˚C Isw (on) = +/-0mA, +/-10mA ∆ V-45- Logic Input to Switch Output Isolation +25˚C Vsw (T
RING
, T
LINE
) = +/-320V Isw - 0.1 1 µA
Logic Inputs = Gnd
+85˚C Vsw (T
RING
, T
LINE
) = +/-330V Isw - 0.3 1 µA
Logic Inputs = Gnd
-40˚C Vsw (T
RING
, T
LINE
) = +/-310V Isw - 0.1 1 µA
Logic Inputs = Gnd
www.clare.com
4
CPC7581
Rev. 2
Table 4. Additional Electrical Characteristics
PARAMETERS CONDITIONS SYMBOL MIN TYP MAX UNITS
Digital Input Characteristics
Input Low Voltage - - - 2.2 1.5 V Input High Voltage - - 3.5 2.2 - V Input Leakage Current (High) V
DD
= 5.5V, V
BAT
= -75V, I
log
- 0.1 1 µA
V
log
= 5V
Input Leakage Current (Low) V
DD
= 5.5V, V
BAT
= -75V, I
log
- 0.1 1 µA
V
log
= 0V
Power Requirements
Power Dissipation VDD= 5V, V
BAT
= -48V,
Idle/Talk State or All Off State IDD, I
BAT
- 5.5 7.5 mW
Ringing State or Access State I
DD
- 6.5 10 mW
VDDCurrent VDD= 5V,
Idle/Talk State or All Off State I
DD
- 1.1 1.5 mA
Ringing State or Access State I
DD
- 1.3 1.9 mA
V
BAT
Current V
BAT
= -48V,
Idle/Talk State or All Off State I
BAT
- 0.1 10 µA
Ringing State or Access State I
BAT
- 0.1 10 µA
Temperature Shutdown Requirements
1
Shutdown Activation Temperature - - 110 125 150 ˚C Shutdown Circuit Hysteresis - - 10 - 25 ˚C
1
Temperature shutdown flag (TSD) will be high during normal operation and low during temperature shutdown state.
Loading...
+ 8 hidden pages