HABITEST LINC OUTPUT CONVERTER
USERS GUIDE
H03-14
The H03-14 Habitest Linc Output Converter was designed to provide 5 Volt TTL
compatible outputs simultaneously while running experiments within the Habitest
System. The H03-14 converts the –28VDC outputs from the H02-08 or H02-01
Habitest Lincs to standard 5Volt, High True, TTL Logic. 14 of the 18 outputs are
available as 5 Volt TTL outputs when the Habitest Linc Output Converter is used
in conjunction with a Habitest Linc.
To use the H03-14 connect the 40-Pin ribbon cable from the Environment Control
Board (H03-04) to the bottom 40-Pin connector labeled “To Connector Board
(H03-04). This connector is located on the side of the H03-14 with the two 40Pin IDC type connectors. The cable is included with ECB (H03-04).
Connect another 40-Pin Ribbon Cable (included with the H03-14) to the top 40Pin connector of the H03-14. This cable also connects to the Habitest Linc (H0208 or H01-02) to either the A or B side. If you need 5 Volt TTL outputs from both
the A and B side of a Habitest Linc you will need two (2) H03-14 Habitest Output
Converters. These connectors provide the -28 volt pass through between the
Habitest Linc and the Environment.
The connector on the other side of the H03-14 is a 26 pin IDC type connector.
This connector contains the converted +5V TTL outputs. The table below
provides the pinout by function for this connector. The cable for this connection
should be provided by the manufacturer of the system that is being interfaced to
the Habitest System. If the cable is not available or your need a cable
manufactured for your applications you can contact Coulbourn Instruments for a
quotation or provide the information below to anyone who will be manufacturing
the cable for you.
26 PIN IDC HEADER PINOUT
PIN # FUNCTION PIN # FUNCTION
1 GND 14 FEEDER2 OP
2 GND 15 TONE
3 SPARE1 16 HOUSE LIGHT
4 SPARE2 17 N/C
5 SPARE3 18 N/C
6 SPARE4 19 GND
7 CUE1-1 20 N/C
8 CUE1-2 21 GND
9 CUE1-3 22 N/C
10 CUE2-1 23 N/C
11 CUE2-2 24 N/C
12 CUE2-3 25 N/C
13 FEEDER1 OP 26 N/C