![](/html/64/643e/643e1e2e6a7fc258de86353847562e3ea858587283540f96b08a67b8f7bd7db3/bg1.png)
80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
10/5 Amps
50-60 Hz
600 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 16.97%, 50% Load)
0.69 0.96 20.99% 10% 76.30 11.97/0.03 3.32/1.21 5.18/1.21 5.17/0.25 60.51 79.30%
1.27 0.98 15.00% 20% 143.40 12.02/0.05 3.31/2.43 5.17/2.42 5.16/0.5 120.96 84.35%
3.14 0.98 16.97% 50% 354.00 12.1/0.13 3.28/6.08 5.11/6.02 5.1/1.26 301.34 85.13%
6.49 0.98 15.37% 100% 734.40 12.29/0.25 3.22/12.15 5.01/12.02 5/2.52 596.62 81.24%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current