80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
6/3 Amps
50-60 Hz
400 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 16.63%, 50% Load)
0.49 0.93 24.92% 10% 52.60 12.06/0.02 3.33/1.16 5.2/1.16 5.18/0.24 40.46 76.93%
0.87 0.97 15.85% 20% 97.60 12.06/0.05 3.32/2.32 5.18/2.31 5.17/0.49 80.93 82.92%
2.12 0.98 16.63% 50% 238.40 12.18/0.12 3.3/5.8 5.14/5.75 5.13/1.2 202.04 84.75%
4.36 0.98 15.00% 100% 493.00 12.36/0.24 3.26/11.61 5.06/11.49 5.05/2.41 401.41 81.42%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-4.0
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
4.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current