Cosmo is constantly making efforts to improve the quality and
performance of our products, so we may make changes to our
appliances without updating this manual.
Download or view an electronic version of our product
manual by visiting: www.cosmoappliances.com
I
N S P I
R ING T
H E W
O R L
D ’ S K I
T C H E N
Remove the Stainless Steel filters. The serial number
is printed on a label inside of the range hood.
Thank you for your purchase. We
know that you have many brands
and products to choose from and
we are honored to know that you
have decided to take one of our
products into your home and hope
that you enjoy it.
Our appliances are designed according to the strictest safety and
performance standards for the
North American market.
We follow the most advanced
manufacturing philosophy.
Each appliance leaves the factory
after thorough quality inspection
and testing. Our distributors and
our service partners are ready to
answer any questions you may
have regarding how to install, use
and care for your range hood.
We hope that this manual will help
you learn to use the product in the
safest and most effective manner
and care for it so that it may give you
the highest satisfaction in cooking for
years to come. If you have any questions or concerns, please contact the
dealer from whom you purchased it,
or contact our Customer Support at:
1-888-784-3108.
The manual also includes
directions for the professional
installer that will install the product
in your home. We recommend
using trained personnel for
professional installation.
Please keep this manual for future use.
IMPORTANT SAFETY INSTRUCTIONS
Read all instructions before using this appliance. Save
these instructions for future references.
Approved for residential appliances. For residential use only.
Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product
TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION
CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR
VAPORS.
CAUTION
To reduce risk of fire and to properly exhaust air, do
not vent exhaust air into spaces within walls,
ceilings, attics, crawl spaces, or garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCT WORK.Install this hood in accordance with all
requirements specified
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufactur
er. If you have questio
2. Before servicing or cleaning the unit, switch power off
at service panel and lock service panel disconnecting means
to prevent power from being switched
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation Work and Electrical Wiring Must Be Done
By Quali ed Person(s) In Accordance With all Aplicable
Codes & Standards, Including Fire-ra
4.
Suf cient air is needed for proper combustion an
exhausting of gases through the flue
burning equipment to prevent back- drafting. Follolow the
heating equipment manufacturers guideline and safety
standards such as those published by the National Fire
Protec
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
Ducted systems must always be vented to the outdoors.
6.
tion Ass
ociation
ns, contac
t the manufacture
on acci-dentally. When
ted Construction.
(Chimney) of fuel
FPA), the American Socie
(N
r.
d
ty for
WARNING
To Reduce The Risk Of Fire Or Electric Shock, Do Not Use
This Hood With Any External Solid State Speed Control
Device.
WARNING
Unplug or disconnect the appliance from the power
supply before servicing.
WARNING
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an elec-trical
short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current. This
appliance is equipped with a cord having a grounding wire with a
grounding plug. The plug must be plugged into an outlet that is
properly installed and grounded.
WARNING - IMPROPER GROUNDING CAN
RESULT IN A RISK OF ELECTRIC SHOCK.
Consult a qualified electrician if the grounding instructions are
not completely understood, or if doubt exists as to whether the
appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualified electrician install an outlet near the
appliance.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
• SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immediate-ly,
EVACUATE AND CALL THE FIRE DEPARTMENT.
• NEVER PICK UP A FLAMING PAN – You may be burned.
• DO NOT USE WATER, including wet dishcloths or towels –
a violent steam ex-plosion will result.
• Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you
already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exi
Always leave safety grills and lters in place.Without these
components, operating blowers could catch onto hair, ngers and
loose clothing.
The manufacturer declines all responsibility in the event
of failure to observe the instructions given here for
installation,maintenance and suitable use of the product. The
manufacturer further declines all responsability for injury due to
negligence and the warranty of the unit automatically expires due
to improper maintenance.
WARNING
WARNING – TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
A. Never leave surface units unattended at high settings.
Boilovers cause sm
Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when
flaming food (i.e. Crepes Suzette, Cherries Jubilee Peppercorn
Beef Flambe).
C. Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filte .
D. Use proper pan size. Always use cookware appropriate for
the size of the surface element.
oking and greasy spillovers that may ignite.
1
STAINLESS STEEL PERMANENT FILTERS
About Your New Filters
Stainless Steel Permanent Filters do not need linings or mesh inside
of the filters and are completely constructed out of stainless steel.
The stainless steel construction allows them to be used again and
again after being cleaned or going through the dishwasher.
How do Permanent Filters work?
They function by forcing the grease filled air to quickly and
continuously change direction as it passes through the filter.
The grease is unable to change direction as fast as the air
carrying them, they end up getting caught on the metal
blades and then trapped into the filter tray.
These filters are both efficient and require less maintenance.
Additional Aluminum or Charcoal Filters can be purchased from:
2
www.cosmoappliances.com
TABLE OF CONTENTS
PARTS DIAGRAM................................................................04
WARRANTY AND SERVICE.................................................19
3
30 INCH MODEL DIMENSIONS COS-QS75
4
TOP VIEW
5
INSTALLATION REQUIREMENTS
WARNING
Sufficient air is needed for proper combustion and exhausting of gases
through the chimney of fuel burning equipment to prevent backdrafting.
Follow the cooking equipment manufacturers guideline and safety
standards such as those published by the National Fire Protection
Association (NFPA), the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code.
When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities. Ducted systems must always be
vented outdoors.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
●
IMPORTANT – Save these instructions for local inspector’s usage.
●
Note to installer – Be sure to leave these instructions with the Consumer.
●
Note to Consumer – Keep these instructions for future reference.
●
Skill Level – Installation of this vent hood requires basic mechanical and
electrical skills.
Proper installation is the responsibility of the installer.
●
CAUTION:
Due to the weight and size of these vent hoods and to reduce the
risk of personal injury or dam-age to the product, TWO PEOPLE
ARE REQUIRED FOR PROPER INSTALLATION.
WARNING
To reduce the risk of the fire or electrical shock, do not use this range
hood with any external solid-state speed control device. Any such
alteration from original factory wiring could result in damage to the unit
and/or create an electrical safety hazard. TO REDUCE THE RISK OF
THE FIRE, USE ONLY METAL DUCTWORK. These vent hoods are
designed to be installed onto a wall or beneath a cabinet.
6
:
PARTS INCLUDED
A
B
H
I
J
PARTS LIST
A) Metal anchors (concrete installations) - 4 pcs
B) Damper Flap - 1
C) Plastic Anchors (drywall installations)- 10 pcs
D) ST4*4x35 mm wood screws - 10 pcs
E) ST4*4x12 mm metal screws - 6 pcs
F) Metal Hinges - 2 pcs
G) Beveled Washers - 10 pcs
H) Remote Control - 1
I) 7.5 in. round duct - 1
J) Metal Duct Clamp - 1
PARTS NEEDED
C
F
G
Measuring tape
Pencil
Phillips screwdriver
Hammer
Tape
Drill
Level
Flathead screwdriver
Safety Gloves
Safety Goggles
7
PRE INSTALLATION PROCEDURES
Please read the instructions carefully. Unpack the Range Hood and check that all
•
functions are working before installing.
Ensure that the voltage (V) and the frequency (Hz) indicated on the sticker match
•
the voltage and frequency at the installation site.
Check that the area behind the installation surface to be drilled is clear of any
•
electrical cables or pipes, etc.
The stainless steel surfaces of the Range Hood are very easily damaged during
•
installation if scratched or bumped by tools. Please take care to protect the
surfaces during installation.
Protect the cooktop surface below with cardboard, or the like, to prevent
•
damage occurring during installation.
The manufacturer shall not be held liable for consumer’s failure to observe and
•
follow all pre-installation procedures and safety regulations.
The vertical distance from the cooking surface to the bottom of the range hood
•
should be at least 24 in. to 36 in. for best performance.
Determine if your installation will be top venting or back venting, and ensure
•
that the openings in the cabinet or wall are in the appropriate locations and
appropriate size.
If this is a new installation, choose the venting method that suits your needs. Cut
•
out openings for the damper and for power access in the cabinet bottom or
exterior wall, depending on the installation method chosen.
DUCTWORK PLANNING
These vent hoods are equipped for 8" round ductwork. This hood may be vented
•
vertically through upper cabinet or ceiling. A duct transition piece is supplied for
vertical exhaust. You may use elbows (sold separately) to vent horizontally
through the rear wall.
Determine the exact location of the vent hood.
•
Plan the route for venting exhaust to the outdoors.
•
Use the shortest and straightest duct route possible. For satisfactory
•
performance,duct run should not exceed 12.5 feet. equivalent length for any duct
configurations.
Use metal ductwork only.
•
WALL FRAMING FOR ADEQUATE SUPPORT
These vent hoods are heavy. Adequate structural support must be provided.
Actual length of straight duct plus duct fitting must equivalent. Equivalent
*
lengths of duct pieces are based on actual tests conducted by Evaluation
Engineering and reflect requirements for good venting performance with any
ventilation hood.
IMPORTANT:
8
Plug the Unit in and Test all Functions Before Installing.
INSTALLATION PROCEDURES
CAUTION: HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR
PROTECTIVE GLOVES WHENEVER IT IS NECESSARY TO REMOVE ANY
PARTS FOR INSTALLING, CLEANING OR SERVICING.
Step 1:
Connect the Duct into the Damper
Secure Duct around Damper with Duct Clamp (included)
9
10
Top /Rear Mounted Installation
* Due to the weight of the unit, we recommend mounting the Range Hood to the bottom of
the cabinet above first and then secure it to wall to avoid a gap. Before starting, locate the
included template to line up at your install location.
1.) Find the key holes at the back and top of the Range Hood. Mark their locations at the installation location using the included templates (Wall / Bottom of Cabinet) with a pencil or
marker.
2.) Drill (4) 5/16" (8mm) holes into wall at each of the marked locations. Insert included drywall
anchors into wall holes. Firmly tap them into place. Insert screws into anchors and leave 1/4"
out for Range Hood to hang on.
3.) Drill an electrical access hole into cabinet above as shown on template.
4.) Locate the top key holes and line up Range Hood with protruding wall screws while also
lining up to holes above and insert wood screws through top holes and fasten the Range
Hood to the bottom of the cabinet by tightening screws with a drill or screwdriver. (this step
requires you to Lift and Hang at the same time / requires two people)
5.) Tighten up screws to secure the Range Hood to the wall once it is fastened to the cabinet.
6.) Run attached ducting through cabinet as required and electrical wires through electrical
access hole.
Drill all holes first
Secure to cabinet
through holes on topDrill from inside unit.
Hang unit on wall
11
TOP VIEW
12
13
14
RECIRCULATING FILTERS INSTALLATION
Skip this page if you are installing a Ducted Range Hood.
Charcoal Filters are only included with Ductless Models
Before installing make sure the unit is powered off and unplugged.
Filter Ring
AFTER CARBON FILTER INSTALLATION
Note: This is a top venting unit and a hole must be cut into the cabinet for proper installation.
Carbon Filter
Installing Recirculating Filters (For Ductless Model Only)
1. Remove the permanent filters from the Range Hood
2. Locate fig.1, unscrew the 6 screws along the Motor Ring (metal circle).
3.
Take your Filter Ring and align the holes on the Motor Ring to the holes of the Filter Ring.
4. Screw the Filter Ring into Motor Ring.
5. Take the Carbon Filter and lock into Filter Ring by aligning the two tabs and twisting.
6. Repeat Steps 1-5 on the other side.
7. Reattach the Permanent Filters.
The carbon filter must be replaced every 4-6 months depending on use.
Additional Aluminum or Permanent Filters can be purchased from
15
OPERATING INSTRUCTIONS
Soft Touch Controls
A. Timer Button - Only works when the range hood fan is running;
touch once. The timer has a default setting of 1 minute.
Use (+) plus or (-) minus to increase or decrease time duration up to 15
minutes depending on how much time you require.
Setting The Time:
Press the Clock symbol (A) when the range hood fan is not running, the
time will light up and blink.
Immediately use the (+) and (-) signs to adjust the hours.
Press the clock symbol again and immediately use the (+) and (-) signs to
adjust the minutes.
After 3 seconds of no buttons being pushed, the time will save.
The clock is in standard 12-hr format.
B. Light. Press to turn light on / off.
C. Minus Button - Used to decrease settings.
(Quick High Speed On)
With the unit OFF, press once as a shortcut to turn on with high speed setting.
D. Plus Button. Used to increase settings.
(Quick Low Speed On)
With the unit OFF, press once as a shortcut to turn on with low speed setting.
E. Power. Press to turn control panel on / off.
16
MAINTENANCE
CAUTION:
NEVER PUT YOUR HAND INSIDE OF THE UNIT WHILE ITS OPERATING.
FOR THE BEST PERFORMANCE CLEAN YOUR RANGE HOOD REGULARLY.
CLEANING
1. Use only mild soap or cleaning solutions to clean the range hoods
outer surface. Dry surfaces using a soft cloth.
2. Stainless Steel cleaner may be used on the external surface.
3. Cleaning the Baffle Filters: For daily cleaning, use hot, soapy water and a soft cloth. Wipe dry and finish with a damp micro-fiber
cloth. Baffle filters can also be cleaned in the dishwasher.
4. Clean the Range Hood assembly once every 6 months.
5. DO NOT clean the motor or electrical components with water or
any other liquid.
REPLACING LIGHT BULBS
CAUTION: LAMP UNIT MAY BE HOT! WAIT UNTIL THE UNIT IS COOL. BEFORE
ATTEMPTING TO REPLACE THE LIGHT BULBS MAKE SURE THE UNIT IS
POWERED OFF AND UNPLUGGED.
Note: Bulb Size GU10.
1. Remove the baffle filters
2. Reach behind the bulb, twist counter clockwise and push the
bulb out of the panel. 3. Plug in new bulb and twist clockwise to
lock into place.
5. Reinstall the baffle filters.
17
TROUBLESHOOTING
CAUTION: ALWAYS UNPLUG UNIT FROM POWER BEFORE SERVICING
PROBLEM
My range hood is
noisy
My range hood has
poor performance..
My range hood shakes.
SOLUTION
A. Check inside the range
hood for any loose debris and
remove.
A. The range hood and cook top
are too far away from each
Optimal distance is 24” to 36”
other.
B. There are too many open
windows or doors in the area.
Close some doors or
windows.
C. The motor performance has
decreased due to wear.
Replace motor.
D. Check and make sure the
tape holding down the
damper flaps at the vent hole
are removed before use.
A. The installation is not secure.
Check again and make sure
the installation hardware is
securely mounted.
B. The fan is broken or not
balanced. Realign or replace
fan.
C. The motor is loose. Check
and make sure the motor is
solidly mounted to the unit.
TOOLS
Phillips Screwdriver
Phillips Screwdriver
Phillips Screwdriver
18
The motor no
longer runs.
Light bulbs went out.
A. Replace control panel or
circuit board.
B. Replace with new motor
assembly.
A. Replace with a new LED
lamp assembly.
Phillips Screwdriver
Phillips Screwdriver
WARRANTY AND SERVICE
TO RECEIVE WARRANTY SERVICE, YOUR PRODUCT MUST
BE REGISTERED. TO REGISTER, VISIT:
WWW.COSMOAPPLIANCES.COM/WARRANTY
FOR FULL WARRANTY DETAILS ON THIS PRODUCT PLEASE VISIT :
HTTP://WWW.COSMOAPPLIANCES.COM/WARRANTY
W
O R L
H
E
G T
I
N
S P I
R I
N
D ’ S K
T
I
C H E
N
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.